Hawaii licensing exam

Hawaii C-37 Plumbing Contractor Exam: Practice Test & Licensing Guide

The PSI trade exam for Hawaii's C-37 plumbing contractor classification: 80 questions on the 2018 UPC and IFGC, plumbing math, medical gas and OSHA. Closed book.

Questions
80
Time limit
3 hours
Passing score
75%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Fixtures and Fittings

What is the maximum flow rate allowed for a public lavatory faucet under Section 407.2.1 of the 2018 UPC?

Requirements at a glance

AgencyHawaii Contractors License Board (DCCA PVL); exams by PSI
ExperienceAt least 4 years of supervisory experience (foreman, supervising employee or contractor) in the classification within the past 10 years (HAR 16-77-18); the Board may accept equivalent training or experience
ExamsC-37 Plumbing Contractor: 80 questions, 3 hours, 75%, plus the Business and Law exam for new applicants
Books allowedNone; closed book
Fees$80 to PSI per exam ($85 for B and A), plus the Board's application and license fees and required insurance

Qualifiers for a Hawaii C-37 plumbing contractor license from the Contractors License Board, in addition to the Business and Law exam.

How to get licensed, step by step

  1. Apply to the Board

    Send the Contractors License Board your application. You can't register with PSI until the Board approves it and sends a letter of approval.

    Contractors License Board (opens in a new tab)Hawaii Administrative Rules 16-77 (contractors) (opens in a new tab)

  2. Schedule Business and Law and the C-37 exam with PSI

    Register online or call PSI at 833-333-4754. Your approval is good for 6 months and you can test as often as you like in that time. After 6 months you need a new application.

    Schedule with PSI (Hawaii trade exams) (opens in a new tab)

  3. Pass both exams

    Each exam needs 75%. If you already hold a Hawaii license and add a classification, you take only the new trade exam.

    Schedule with PSI (Hawaii trade exams) (opens in a new tab)

  4. Get licensed

    Send the Board your results and proof of the insurance (workers' compensation and liability) the license requires.

    Contractors License Board (opens in a new tab)Hawaii Revised Statutes chapter 444 (contractors) (opens in a new tab)

How to prepare

  • Hawaii's trade exams are PSI exams on specific editions: the 2020 NEC, the 2018 UPC, IMC, IFGC and IBC. Hawaii's state electrical code is older than the 2020 NEC, so study to the editions on PSI's bulletin, and check the bulletin again before test day.
  • Contractor exams are closed book except C-13, where PSI provides the NEC. Electrician exams provide the NEC too. Plumber and other contractor exams allow no reference books.
  • Sewer, drain, waste, vent and excavation (15) and general knowledge (12) lead the exam; plumbing math is 10.
  • Medical gas (5) and fuel gas (5) come from the UPC and IFGC.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • 2018 Uniform Plumbing Code (UPC), IAPMOEssential

    On PSI's outline, closed book. Code questions are based only on this edition.

    IAPMO store (opens in a new tab)Read free (IAPMO) (opens in a new tab)

  • 2018 International Fuel Gas Code (IFGC), ICC

    On PSI's outline, closed book. Fuel gas piping and venting questions.

  • Mathematics for Plumbers and Pipefitters, 8th Edition (2013), Delmar Cengage

    On PSI's outline, closed book. Source of the plumbing math questions.

  • 29 CFR Part 1926 (OSHA construction standards)

    On PSI's outline, closed book. Safety questions.

    Read free (eCFR) (opens in a new tab)

Official reference list (as published by the testing agency)
  • Uniform Plumbing Code (UPC), 2018 edition, IAPMO (not allowed in the exam room)
  • International Fuel Gas Code (IFGC), 2018 edition, ICC (not allowed)
  • Mathematics for Plumbers and Pipefitters, 8th edition, 2013, Delmar Cengage Learning (not allowed)
  • 29 CFR Part 1926 (OSHA construction standards) (not allowed)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Knowledge12
Fixtures and Fittings5
Storm and Roof Drainage5
Fuel Gas Systems5
Safety OSHA8
Water Supply and Distribution10
Water Heaters5
Sewer, Drain, Waste and Vent Systems and Excavation15
Plumbing Math10
Medical Gas5

Exam day details

  • Administered by PSI Services for the Hawaii Contractors License Board.
  • Fee: $80 to PSI. The Contractors License Board's application and license fees are separate.
  • 80 scored questions in 3 hours; 60 correct (75%) to pass. The exam is closed book.
  • The Board must approve your application before you can register with PSI. Your eligibility lasts 6 months, and you can test as often as you like within it.
  • PSI may add up to 10 unscored pretest questions; they do not count against your time.
  • Closed-book and open-book rules are on each exam page. PSI provides an online calculator, or you can bring a silent, non-programmable one.

Frequently asked questions

What's on the Hawaii C-37 exam?

80 scored questions: sewer, drain, waste, vent and excavation 15, general knowledge 12, water supply and distribution 10, plumbing math 10, safety OSHA 8, fixtures and fittings 5, storm and roof drainage 5, fuel gas 5, water heaters 5 and medical gas 5.

Which codes are used?

The 2018 UPC and the 2018 IFGC, plus Mathematics for Plumbers and Pipefitters (8th edition) for the math.

Do I also take Business and Law?

Yes, if you are a new applicant.

Free questions with answers

Show all 10 free questions and answers
  1. What is the maximum flow rate allowed for a public lavatory faucet under Section 407.2.1 of the 2018 UPC?

    Answer: 0.5 gpm at 60 psi

    Section 407.2.1 limits public lavatory faucets to 0.5 gpm at 60 psi. The 2.2 gpm at 60 psi figure is the limit for private lavatory faucets and for kitchen sink faucets, and 2.5 gpm at 80 psi is the showerhead limit in Section 408.2.

    Reference: 2018 Uniform Plumbing Code (IAPMO), 407.2.1

  2. A 76,000 Btu/h gas-fired storage water heater is being protected with a temperature and pressure relief valve. What is the minimum discharge capacity of the valve under Section 504.6, and may a shutoff valve be placed on its discharge line?

    Answer: At least 76,000 Btu/h, and no shutoff valve may be on the discharge pipe

    Section 504.6 requires the relief valve's hourly Btu discharge capacity to be not less than the water heater input rating, so 76,000 Btu/h. It also prohibits any shutoff valve between the relief valve and the heater or on the discharge pipe between the valve and the atmosphere.

    Reference: 2018 Uniform Plumbing Code (IAPMO), 504.6

  3. A steel gas pipe with a 1.315 inch outside diameter must be bent in the field. What is the smallest permitted inside radius for the bend under IFGC Section 405.2, to the nearest hundredth of an inch?

    Answer: 7.89 inches

    Section 405.2 requires the inside radius of a bend in metallic pipe to be not less than 6 times the outside diameter: 6 x 1.315 = 7.89 inches. Three times the OD (3.95) is too small, 6 x 1.0 uses the nominal size instead of the OD, and 25 x 1.315 = 32.88 is the plastic pipe rule in Section 405.3 (and that uses inside diameter).

    Reference: 2018 International Fuel Gas Code, 405.2

  4. An open areaway of 80 square feet serves as the entrance to a basement. What is the minimum size of the areaway drain under Section 1101.8, and where may it discharge?

    Answer: 2 inches, discharging in the manner provided for subsoil drains

    Section 1101.8 requires areaway drains at least 2 inches in diameter for areaways up to 100 square feet, discharged in the manner provided for subsoil drains. Areaways over 100 square feet may not drain into subsoil drains and are sized by Table 1103.2.

    Reference: 2018 Uniform Plumbing Code (IAPMO), 1101.8

  5. Under UPC Section 1308.4, what type of tube is used for medical gas piping at ordinary operating pressures?

    Answer: Hard-drawn seamless copper ASTM B819 medical gas tube, Type L

    Section 1308.4 calls for hard-drawn seamless copper ASTM B819 medical gas tube, Type L. Type K is used only where operating pressure is above 185 psi and the size is larger than DN80 (3-1/8 inch O.D.). The tube carries the manufacturer's marking such as OXY or MED.

    Reference: 2018 Uniform Plumbing Code (IAPMO), 1308.4

  6. Using the OSHA maximum allowable slope for Type C soil (1-1/2 horizontal to 1 vertical), what is the top width of an 8-foot-deep sloped trench that is 4 feet wide at the bottom, with both sides sloped?

    Answer: 28 feet

    Appendix B to Subpart P (Table B-1) gives 1-1/2:1 for Type C soil. Each side runs 1.5 x 8 = 12 feet horizontally. Top width = 4 + 12 + 12 = 28 feet. Sloping only one side gives 16, using a 1:1 slope (Type B) gives 4 + 8 + 8 = 20, and using a 1/2:1 slope gives 12.

    Reference: 29 CFR Part 1926 (OSHA construction standards), 1926 Subpart P, Appendix B, Table B-1

  7. A pressure regulator and a water softener are installed in a building supply line. Under Section 609.5, how close must unions be to this equipment?

    Answer: Within 12 inches, so the equipment can be readily removed

    Section 609.5 requires unions in the water supply piping within 12 inches of regulating equipment, water heating equipment, conditioning tanks and similar equipment that requires service by removal or replacement. The purpose is to allow ready removal.

    Reference: 2018 Uniform Plumbing Code (IAPMO), 609.5

  8. A lavatory has a 1-1/2 inch trap arm. Using Table 1002.2, what is the maximum horizontal length from the trap weir to the inner edge of its vent?

    Answer: 42 inches

    Table 1002.2 lists maximum trap arm lengths of 30 inches for a 1-1/4 inch arm, 42 inches for 1-1/2 inch, 60 inches for 2 inch, 72 inches for 3 inch and 120 inches for 4 inch, all at 1/4 inch per foot slope. A 1-1/2 inch arm is limited to 42 inches (3 ft 6 in).

    Reference: 2018 Uniform Plumbing Code (IAPMO), Table 1002.2

  9. How must underground piping be supported in a trench under Section 313.5?

    Answer: On a firm bed for its entire length

    Section 313.5 requires piping in the ground to be laid on a firm bed for its entire length, unless other support is approved under Section 301.2. Spot supports or blocks leave unsupported spans that can settle and break.

    Reference: 2018 Uniform Plumbing Code (IAPMO), 313.5

  10. A 22-1/2 degree offset has a set of 12 inches. Using a travel factor of 2.613 for 22-1/2 degree fittings, what is the travel?

    Answer: 31.36 inches

    Travel = set x 2.613 = 12 x 2.613 = 31.36 inches. The 12.98 figure uses 1.082 (the travel factor for 67-1/2 degree fittings), 16.97 uses the 45 degree factor 1.414, and 24 simply doubles the set.

    Reference: Mathematics for Plumbers and Pipefitters, 8th edition, General practice: 22-1/2 degree offset travel = set x 2.613

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.