Requirements at a glance
| Agency | D.C. Board of Industrial Trades, Department of Licensing and Consumer Protection (DLCP); exam by PSI |
|---|---|
| Exam | 80 multiple-choice questions, 3.5 hours (exam ID 311); Pass score not published; PSI reports PASS or FAIL |
| Experience | Not confirmed; see the Board's page |
| Books | Open book: bound references only, permanent tabs, notes in ink or highlighting in code sections only; no writing during the exam |
| Fees | $52 to PSI per exam; D.C. application and license fees are separate |
Refrigeration and air conditioning mechanics applying to the Board of Industrial Trades for the unlimited master license.
Official links
How to get licensed, step by step
Meet the experience requirement
The DLCP refrigeration instructions were not available to us; check the Board's page for the experience and documents required.
Apply to the District
Submit the online application and fees to the Board of Industrial Trades. Approved candidates receive a notice of eligibility.
Register with PSI
Register by phone at (855) 557-0616 or online, giving the exam ID and title. Pay the $52 exam fee by credit or debit card when you book.
Register with PSI: refrigeration exams (opens in a new tab)PSI: Washington D.C. Candidate Information Bulletin (8/25/2022) (opens in a new tab)
Take the exam
Bring your listed references and matching ID. You see PASS or FAIL right after the exam. To retest you must reapply with the District first.
PSI: Washington D.C. Candidate Information Bulletin (8/25/2022) (opens in a new tab)
How to prepare
- Theory, system types and general requirements are 30% of the exam; refrigerant and condensate piping (12%) and evaporators, compressors and condensers (15%) follow.
- The PSI bulletin (8/25/2022) lists older editions than the District's adopted 2017 DC Construction Codes (2014 NEC, 2015 ICC codes). Confirm the current reference list with PSI (855-557-0616) or the DLCP before you buy books.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2012 IMC and Modern Refrigeration. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2012 International Mechanical Code (IMC), ICCEssential
The edition on the PSI bulletin (8/25/2022). Confirm the current list with PSI or the DLCP.
Modern Refrigeration and Air Conditioning (2004 edition)Essential
Listed on the PSI bulletin for the refrigeration and air conditioning exams.
Official reference list (as published by the testing agency)
- 2012 International Mechanical Code (IMC)
- Modern Refrigeration and Air Conditioning (2004 edition)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Theory, System Types, Terminology, and General Requirements | 30 | |
| Refrigerant and Condensate Piping | 12 | |
| Evaporators, Compressors, Condensers, Chillers, Cooling Towers, Heat Pumps, Heating and AC Appliances | 15 | |
| Conditioned Air, Supply, Return, Makeup, Combustion Air, Air Ducts, Dampers, and Insulation | 7 | |
| Electrical Fundamentals and Controls | 9 | |
| Refrigerants | 10 | |
| Operating Procedures, including Safety | 9 | |
| Maintenance and Repairs | 8 |
The outline totals 100; the other items on the 80-question exam are unscored or unassigned.
Exam day details
- Administered by PSI Services for the District of Columbia Board of Industrial Trades (DLCP).
- Fee: $52 to PSI per computer-based exam. D.C. application and license fees are separate.
- PSI exam ID 311: 80 multiple-choice questions, open book, 3.5 hours. The content outline is the PSI bulletin's.
- The bulletin's references are the 2012 IMC and Modern Refrigeration and Air Conditioning (2004); the District's adopted construction codes are newer (2015 ICC codes). Confirm the current list with PSI or the DLCP.
- You apply to the Board online and pay the application fees first. Approved candidates get a notice of eligibility, then register with PSI at (855) 557-0616 or on PSI's D.C. pages using the exam ID and title.
- Open book: bring only the references the bulletin lists. They must be bound (original, three-ring binder or stapled); photocopies of copyrighted material are not allowed. Notes in ink or highlighting are allowed in code sections only, and tabs must be permanently attached.
- You may not write or mark in your references during the exam. PSI gives you a whiteboard, markers and scratch paper. Bring a battery-operated, non-programmable calculator without a printer.
- Your name on the reservation must match your ID or you cannot test and forfeit the fee. Restroom breaks are limited to 5 minutes and the clock keeps running.
- You see your result right after the exam. Passing candidates are told PASS with no numeric score; candidates who fail get diagnostic feedback by content area.
- To retest you must reapply with the District before each attempt. The bulletin recommends allowing time to study before registering again.
Note: The PSI bulletin (updated 8/25/2022) lists the 2011 NEC and the 2012 IPC, IFGC and IMC, while the District's adopted construction codes are the 2017 DC Construction Codes (2014 NEC and 2015 ICC codes with D.C. amendments, effective May 29, 2020). We follow the editions on the bulletin. Confirm the current reference list with PSI (855-557-0616) or the DLCP before you buy books. No pass score is published.
Frequently asked questions
How many questions are on the D.C. master a/c and refrigeration mechanic (unlimited) exam?
PSI lists 80 multiple-choice questions in 3.5 hours (exam ID 311), open book. The biggest areas are Theory, System Types, Terminology, and General Requirements (30%), Evaporators, Compressors, Condensers, Chillers, Cooling Towers, Heat Pumps, Heating and AC Appliances (15%), Refrigerant and Condensate Piping (12%).
What is the passing score?
Neither PSI nor the Board of Industrial Trades publishes a passing score. PSI shows PASS or FAIL right after the exam, with no numeric score for passing candidates and diagnostic feedback for those who fail.
Which code edition does the exam use?
PSI's bulletin lists the 2012 International Mechanical Code and Modern Refrigeration and Air Conditioning (2004). The District has since adopted the 2015 ICC codes in the 2017 DC Construction Codes, so confirm the current reference list with PSI or the DLCP before you buy books.
Free questions with answers
Show all 10 free questions and answers
A supply fan delivers 2,000 cfm of air that is cooled from 80 degrees F entering to 60 degrees F leaving the coil, with no moisture removed. Using the sensible heat formula Q = 1.08 x cfm x TD, what is the sensible cooling load?
Answer: 43,200 Btu/h
Q = 1.08 x 2,000 cfm x 20 degrees F = 43,200 Btu/h. Leaving out the 1.08 factor gives 40,000. Dividing by the temperature difference gives 108, and the 4.5 factor used with enthalpy would give 4.5 x 2,000 x 20 = 180,000, which is not a sensible-only formula.
Reference: General practice (refrigeration), Sensible heat of air: Q = 1.08 x cfm x temperature difference
A technician reads 38 degrees F as the saturation temperature for the evaporator pressure on a pressure-temperature chart. A thermometer on the suction line at the evaporator outlet reads 51 degrees F. What is the evaporator superheat?
Answer: 13 degrees F
Superheat is the actual vapor temperature minus the saturation temperature at the same pressure: 51 - 38 = 13 degrees F. Adding the two numbers gives 89. Using 38 alone ignores the line temperature, and 51 - 32 = 19 wrongly uses the freezing point of water as the reference.
Reference: General practice (refrigeration), Superheat calculation
Which copper tube may be used for field-erected refrigerant piping under the 2012 IMC without special approval?
Answer: Seamless Type ACR tube (hard or annealed) that complies with ASTM B 280
Section 1107.5.3 requires seamless Type ACR copper tube complying with ASTM B 280 for refrigerant piping erected on the premises. Types K, L and M (ASTM B 88) may be used only where approved. Annealed tube may not be larger than 2 inches nominal size.
Reference: 2012 International Mechanical Code, Section 1107.5.3
Which description matches the 2012 IMC definition of an evaporator?
Answer: The part of the system in which liquid refrigerant is vaporized to produce refrigeration
Chapter 2 defines the evaporator as the part of the system in which liquid refrigerant is vaporized to produce refrigeration. Liquefying vapor is the condenser's job, compression is done by the compressor, and storing liquid is the function of a liquid receiver.
Reference: 2012 International Mechanical Code, Chapter 2, Definitions: Evaporator
Which definition in Chapter 2 of the 2012 IMC fits a condenser?
Answer: A heat exchanger designed to liquefy refrigerant vapor by removal of heat
The condenser is the heat exchanger that rejects heat and turns hot refrigerant vapor into liquid. The vaporizing exchanger is the evaporator, and a compressor with its prime mover is a compressor unit.
Reference: 2012 International Mechanical Code, Chapter 2, Definitions: Condenser
Externally insulated ducts used for cooling must have what covering under Section 604.11 of the 2012 IMC, unless the insulation is already vapor-tight?
Answer: A vapor retarder of 0.05 perm maximum, or aluminum foil at least 2 mils thick, with sealed joints and seams
Section 604.11 requires a vapor retarder with a permeance of not more than 0.05 perm or aluminum foil at least 2 mils (0.051 mm) thick over externally insulated cooling ducts. Insulation that is itself 0.05 perm or less needs no cover, and all joints and seams must be sealed to maintain continuity of the retarder.
Reference: 2012 International Mechanical Code, Section 604.11
Two resistances of 12 ohms and 4 ohms are connected in parallel. What is the total resistance?
Answer: 3 ohms
For two resistors in parallel, R = (R1 x R2) / (R1 + R2) = (12 x 4) / 16 = 3 ohms. Adding them gives 16 (series), averaging gives 8, and dividing the larger by two gives 6; parallel resistance is always less than the smallest branch.
Reference: General practice (refrigeration), Parallel circuit resistance
A technician replaces a liquid-line filter-drier on an R-410A system. The repair is not major, and the system will not be evacuated to the atmosphere afterward. Under 40 CFR 82.156(a)(1), to what pressure must the appliance be evacuated before it is opened?
Answer: No higher than 0 psig
Section 82.156(a)(1) allows evacuation to no higher than 0 psig for a medium-, high- or very high-pressure appliance when the repair is not major and the system will not be evacuated to the atmosphere after service. Major repair means removing the compressor, condenser, evaporator or auxiliary coil, or uncovering an opening over 4 square inches for more than 15 minutes; replacing a drier is not major.
Reference: 40 CFR Part 82 Subpart F, 40 CFR 82.156(a)(1); 82.152 Definitions
Before a technician works on the wiring of an outdoor condensing unit, what is the correct safety procedure?
Answer: Open and lock out the disconnect, tag it, and verify with a meter that the circuit is de-energized
Standard lockout and tagout practice is to open the disconnect, lock and tag it, and then test for absence of voltage with a meter before working. Turning off a thermostat does not remove line voltage from the unit, and an unlocked disconnect can be closed by someone else.
Reference: General practice (refrigeration), Electrical safety: lockout and tagout
After a severe compressor motor burnout, which action is standard practice before installing the replacement compressor?
Answer: Clean up the system, test the oil for acid, and install suction-line and liquid-line filter-drier protection
A burnout produces acid, carbon and sludge that spread through the system. Standard practice is to recover the refrigerant, clean or replace contaminated components, test the oil for acid, and install a new liquid-line drier and a suction-line filter-drier to catch contaminants. Compressed air adds moisture, and a used drier is already saturated.
Reference: General practice (refrigeration), Compressor burnout cleanup
Sources
- PSI: Washington D.C. Contractor/Trades Examinations Candidate Information Bulletin (updated 8/25/2022) (opens in a new tab)
- D.C. Board of Industrial Trades (DLCP) (opens in a new tab)
- D.C. online license application (opens in a new tab)
- D.C. Department of Buildings: DC Construction Codes (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.