Requirements at a glance
| Agency | Colorado State Plumbing Board (DORA); exam by PSI |
|---|---|
| Experience | 2 years (3,400 hours) of practical experience |
| Exam | 100 scored questions (plus unscored ones) in 240 minutes, 70% to pass |
| Code book | 2024 IPC and 2024 IRC |
| Fees | $78 PSI exam ($73 retest), plus DORA's application fee |
Plumbers who work on one- and two-family dwellings and have two years (3,400 hours) of practical experience.
Official links
How to get licensed, step by step
Get your hours
Work under a licensed plumber and keep records your supervisors can verify. 2 years (3,400 hours) of practical experience.
Register with PSI
Register and schedule online or by phone. The exam fee is good for one year.
Schedule with PSI (Colorado plumbing) (opens in a new tab)PSI: Colorado plumbing candidate bulletin (opens in a new tab)
Pass the Residential Plumber exam
100 scored questions (plus unscored ones) in 240 minutes, 70% to pass. The 2024 IPC and 2024 IRC is provided at the test center.
Apply to DORA
After you pass, apply to the State Plumbing Board with your experience verification. Passing doesn't guarantee a license until the board approves your hours.
DORA: Plumbing Board applications and requirements (opens in a new tab)
How to prepare
- PSI hands you an unmarked code book: no tabs, highlights or notes. Practice with a clean copy and learn the index and the article/chapter layout instead of relying on tabs.
- There's no per-section minimum, so don't get stuck. Skip hard lookups, finish the easy ones, then come back.
- Vents and sanitary drainage are 42 of the 100 questions. The IRC plumbing chapters (P25–P33) cover most residential work.
- Formulas aren't provided: know slope, fall over distance and fixture-unit sizing.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2024 IRC and the 2024 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2024 International Residential Code (IRC), plumbing chapters P25–P33Essential
Provided at the test center. Most residential plumbing and the residential fire sprinkler (P2904) questions.
ICC store (opens in a new tab)Read free (opens in a new tab)
2024 International Plumbing Code (IPC)Essential
Provided at the test center from November 1, 2026. Commercial and general plumbing questions.
ICC store (opens in a new tab)Read free (opens in a new tab)
Official reference list (as published by the testing agency)
- International Plumbing Code (IPC), 2024, and International Residential Code (IRC), 2024 (provided at the test center; 2021 books on request until February 1, 2027)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Water Supply | 18 | |
| Vents | 21 | |
| Fixtures and Equipment | 12 | |
| General Regulations | 11 | |
| Traps | 5 | |
| Sanitary Drainage Systems | 21 | |
| Residential Fire Sprinklers | 4 | |
| Water Heaters | 8 |
Exam day details
- Administered by PSI Services for the Colorado State Plumbing Board (DORA).
- Fee: $78 to PSI ($73 to retake). The fee is valid for one year. DORA's license application fee is separate.
- 100 scored questions in 240 minutes, plus up to 10 unscored questions with 30 extra minutes. You need 70 correct.
- From November 1, 2026 the exams use the 2024 IPC and IRC. They test the model codes, not Colorado's state amendments.
- PSI provides the code books. You can't bring your own or write in the ones provided. Formulas aren't provided, so know your pipe-sizing and slope math.
- Overall score only: there is no minimum per section.
Frequently asked questions
Which code is the Colorado residential plumber exam based on?
The 2024 International Plumbing Code and 2024 International Residential Code from November 1, 2026 (the 2021 books are available on request until February 1, 2027). Colorado's state amendments aren't tested.
What's on the Colorado Residential Plumber exam?
100 scored questions. Vents (21) and sanitary drainage (21) are the biggest areas, then water supply (18), fixtures (12) and general regulations (11).
How much experience do I need for a Colorado residential plumber license?
Two years (3,400 hours) of practical plumbing experience, verified to the State Plumbing Board.
Free questions with answers
Show all 10 free questions and answers
A section of new DWV rough-in in a house is being water tested. To what minimum height must the section be filled, and how long must the water be held?
Answer: 10 feet above the highest fitting, held 15 minutes
Section P2503.5.1 (rough plumbing) requires each section under a water test to be filled to at least 10 feet above the highest fitting connection in that section, or to the highest point of the completed system, and held for 15 minutes with no visible leaks. The 10-foot head is measured from the highest fitting, not the lowest. The 5-foot head and the 30- and 60-minute holds do not appear in the IRC water test.
Reference: 2024 International Residential Code, Section P2503.5.1
A water closet is being roughed in next to a bathroom side wall. What is the minimum distance from the centerline of the water closet to the side wall?
Answer: 15 inches
Section P2705.1, item 5, does not allow a water closet, lavatory or bidet closer than 15 inches from its center to any side wall, partition or vanity, or closer than 30 inches center-to-center between adjacent fixtures. 21 inches is the clear space required in front of the fixture, not the side distance.
Reference: 2024 International Residential Code, Section P2705.1, item 5
A storage water heater in an upstairs closet needs a pan because a leak would cause damage. What are the minimum pan depth and drain size?
Answer: 1-1/2 inches deep with a 3/4-inch drain
Section P2801.5.1 requires the pan to be at least 1-1/2 inches deep and big enough to catch drips or condensate from the tank. It must drain through an indirect waste pipe at least 3/4 inch in diameter. Per P2801.5, a metal pan must be at least 0.0236-inch galvanized steel or aluminum, and a plastic pan at least 0.036 inch thick.
Reference: 2024 International Residential Code, Sections P2801.5 and P2801.5.1
A gas water heater that is not listed as flammable vapor ignition-resistant is installed in a garage. How high above the garage floor must its ignition source be?
Answer: 18 inches
Section P2801.6 requires water heaters with an ignition source in a garage to be elevated so the ignition source is at least 18 inches above the floor. Gasoline vapors are heavier than air and collect near the floor. The exception exempts appliances listed as flammable vapor ignition-resistant.
Reference: 2024 International Residential Code, Section P2801.6
A pedestal lavatory's trap is being placed. What are the maximum distances from the fixture outlet to the trap?
Answer: 24 inches vertically to the weir; 30 inches horizontally
Section P3201.6 limits the vertical distance from the fixture outlet to the trap weir to 24 inches. The horizontal distance, measured from the centerline of the fixture outlet to the centerline of the trap inlet, is limited to 30 inches. 42 inches is the maximum standpipe height in P2706.1.2.
Reference: 2024 International Residential Code, Section P3201.6
A house has two full-bath groups with tubs, one half-bath group, a kitchen group and a laundry group. Using the combined column of Table P2903.7, what is the total load in water supply fixture units?
Answer: 14.8 w.s.f.u.
Table P2903.7 (combined column): full-bath group 3.6, half-bath group 2.6, kitchen group 2.5, laundry group 2.5. Total = 3.6 + 3.6 + 2.6 + 2.5 + 2.5 = 14.8 w.s.f.u. 10.7 comes from adding only the cold column (2.7 + 2.7 + 2.5 + 1.0 + 1.8). 19.0 uses drainage fixture units from Table P3004.1 (5 + 5 + 4 + 2 + 3). 11.2 counts only one full bath.
Reference: 2024 International Residential Code, Section P2903.7 and Table P2903.7
A vent terminal will be 6 feet horizontally from an openable second-floor window. How must it be placed relative to the window?
Answer: At least 3 feet above the top of the window
Section P3103.5 says a vent terminal may not be less than 4 feet directly beneath a door, openable window or other air intake. It also may not be within 10 feet horizontally of such an opening unless it is at least 3 feet above the top of the opening. At 6 feet horizontally, the terminal is within 10 feet, so it must be at least 3 feet above the top of the window. The 4-foot figure is only about vents directly below an opening.
Reference: 2024 International Residential Code, Section P3103.5
Using Table P3105.1, what is the maximum developed length from the trap weir to the vent for a 1-1/2-inch trap on a fixture drain sloped 1/4 inch per foot?
Answer: 6 feet
Table P3105.1 allows 5 feet for a 1-1/4-inch trap, 6 feet for 1-1/2 inches, and 8 feet for 2 inches, all at 1/4 inch per foot. 3- and 4-inch traps at 1/8 inch per foot get 12 and 16 feet. Self-siphoning fixtures such as water closets have no limit (P3105.1, Exception).
Reference: 2024 International Residential Code, Section P3105.1 and Table P3105.1
A house has two full baths with tubs and 1.6-gpf water closets, a kitchen group, and a laundry group. Using Table P3004.1, including its multiple-bath-group values, what is the total drainage load?
Answer: 13 dfu
Table P3004.1 assigns 8 dfu for 2 baths in the multiple-bath-group row, which accounts for the chance that both are used at once. The kitchen group is 2 dfu and the laundry group is 3 dfu. Total: 8 + 2 + 3 = 13 dfu. 15 dfu adds two separate full-bath groups at 5 each, ignoring the multiple-bath reduction that P3005.4 tells you to use. 17 dfu uses the more-than-1.6-gpf value of 6 per bath, and 10 dfu leaves out the laundry group.
Reference: 2024 International Residential Code, Table P3004.1 and Section P3005.4
A building drain will carry 45 dfu at a slope of 1/4 inch per foot. Using Table P3005.4.2, what is the minimum drain size?
Answer: 4 inches
Table P3005.4.2 allows a 3-inch building drain 36 dfu at 1/8 inch per foot, 42 dfu at 1/4 inch and 50 dfu at 1/2 inch. At 1/4 inch per foot, 45 dfu is over the 3-inch limit of 42, so a 4-inch drain is required (216 dfu at 1/4 inch). A 3-inch drain would work only if it were sloped 1/2 inch per foot.
Reference: 2024 International Residential Code, Section P3005.4.2 and Table P3005.4.2
Sources
- PSI: Colorado State Plumbing Board Candidate Information Bulletin (opens in a new tab)
- Colorado DORA: Plumbing Board applications and requirements (opens in a new tab)
Questions last verified October 20, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.