Requirements at a glance
| Agency | Colorado State Plumbing Board (DORA); exam by PSI |
|---|---|
| Experience | 4 years (6,800 hours) of practical experience |
| Exam | 100 scored questions (plus unscored ones) in 240 minutes, 70% to pass |
| Code book | 2024 IPC and 2024 IRC |
| Fees | $78 PSI exam ($73 retest), plus DORA's application fee |
Plumbers with four years (6,800 hours) of practical experience. Six-year apprentices take the same outline.
Official links
How to get licensed, step by step
Get your hours
Work under a licensed plumber and keep records your supervisors can verify. 4 years (6,800 hours) of practical experience.
Register with PSI
Register and schedule online or by phone. The exam fee is good for one year.
Schedule with PSI (Colorado plumbing) (opens in a new tab)PSI: Colorado plumbing candidate bulletin (opens in a new tab)
Pass the Journeyworker Plumber exam
100 scored questions (plus unscored ones) in 240 minutes, 70% to pass. The 2024 IPC and 2024 IRC is provided at the test center.
Apply to DORA
After you pass, apply to the State Plumbing Board with your experience verification. Passing doesn't guarantee a license until the board approves your hours.
DORA: Plumbing Board applications and requirements (opens in a new tab)
How to prepare
- PSI hands you an unmarked code book: no tabs, highlights or notes. Practice with a clean copy and learn the index and the article/chapter layout instead of relying on tabs.
- There's no per-section minimum, so don't get stuck. Skip hard lookups, finish the easy ones, then come back.
- Storm drainage (10) is commercial work: practice IPC Chapter 11 roof drain and leader sizing by rainfall rate.
- Isometric analysis means reading a riser drawing and sizing the drain, waste and vent from fixture units.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2024 IPC and the 2024 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2024 International Plumbing Code (IPC)Essential
Provided at the test center from November 1, 2026. Commercial and general plumbing questions.
ICC store (opens in a new tab)Read free (opens in a new tab)
2024 International Residential Code (IRC), plumbing chapters P25–P33Essential
Provided at the test center. Most residential plumbing and the residential fire sprinkler (P2904) questions.
ICC store (opens in a new tab)Read free (opens in a new tab)
Official reference list (as published by the testing agency)
- International Plumbing Code (IPC), 2024, and International Residential Code (IRC), 2024 (provided at the test center; 2021 books on request until February 1, 2027)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Water Supply | 15 | |
| Vents | 18 | |
| Fixtures and Equipment | 8 | |
| General Regulations | 5 | |
| Traps, Interceptors, and Separators | 5 | |
| Storm Drainage Systems | 10 | |
| Sanitary Drainage Systems | 20 | |
| Indirect and Special Waste Piping | 5 | |
| Isometric Analysis | 5 | |
| Residential Fire Sprinklers | 2 | |
| Water Heaters | 7 |
Exam day details
- Administered by PSI Services for the Colorado State Plumbing Board (DORA).
- Fee: $78 to PSI ($73 to retake). The fee is valid for one year. DORA's license application fee is separate.
- 100 scored questions in 240 minutes, plus up to 10 unscored questions with 30 extra minutes. You need 70 correct.
- From November 1, 2026 the exams use the 2024 IPC and IRC. They test the model codes, not Colorado's state amendments.
- PSI provides the code books. You can't bring your own or write in the ones provided. Formulas aren't provided, so know your pipe-sizing and slope math.
- Overall score only: there is no minimum per section.
Frequently asked questions
Is it journeyman or journeyworker plumber in Colorado?
Colorado's official title is Journeyworker Plumber. It's the same license people call journeyman plumber.
Which code is the Colorado journeyworker plumber exam based on?
The 2024 IPC and 2024 IRC from November 1, 2026, provided at the test center. Colorado's state amendments aren't tested.
What's on the Colorado journeyworker plumber exam?
100 scored questions: sanitary drainage (20), vents (18), water supply (15), storm drainage (10), and smaller sections on fixtures, water heaters, traps and interceptors, indirect waste, isometrics and residential sprinklers.
Free questions with answers
Show all 10 free questions and answers
A 2-inch trap serves a floor sink, and its fixture drain is run at 1/4 inch per foot. Using the trap-to-vent table, what is the maximum developed length from the trap weir to the vent fitting?
Answer: 8 feet
Table 909.1 lists a maximum distance of 8 feet for a 2-inch trap at 1/4 inch per foot. The 5-foot and 6-foot values are for 1-1/4-inch and 1-1/2-inch traps, and 12 feet applies to a 3-inch trap at 1/8 inch per foot. The distance is measured along the fixture drain from the trap weir to the vent fitting (Section 909.1).
Reference: 2024 International Plumbing Code, Section 909.1, Table 909.1
A 4-inch soil stack carries 140 drainage fixture units. Its vent stack will have a developed length of 180 feet. Using the stack vent and vent stack sizing table, what is the minimum vent stack diameter?
Answer: 3 inches
In Table 906.1, the row for a 4-inch stack with 140 dfu allows 27 feet for a 2-inch vent, 65 feet for 2-1/2 inches, 200 feet for 3 inches and 750 feet for 4 inches. A 180-foot vent is too long for 2-1/2 inches but within the 200-foot limit for 3 inches. Section 906.1 also requires at least one-half the drain diameter (2 inches), and 3 inches meets that.
Reference: 2024 International Plumbing Code, Section 906.1, Table 906.1
How far horizontally may a fixture trap be from the fixture outlet, measured from the centerline of the fixture outlet to the centerline of the trap inlet?
Answer: 30 inches
Section 1002.1 limits the horizontal distance from the fixture outlet centerline to the trap inlet centerline to 30 inches. The vertical distance from the fixture outlet to the trap weir is limited to 24 inches, which is the distractor. Fixtures with integral traps are exempt, and a fixture must never be double trapped.
Reference: 2024 International Plumbing Code, Section 1002.1
A building drain will carry 200 drainage fixture units and must be installed at 1/8 inch per foot. Using the building drain and sewer table, what is the minimum pipe size?
Answer: 5 inches
In Table 710.1(1), a 4-inch building drain at 1/8 inch per foot is limited to 180 dfu (216 at 1/4 inch per foot). With 200 dfu, 4 inches is too small at this slope. A 5-inch drain at 1/8 inch per foot takes 390 dfu, so 5 inches is the minimum. Picking 4 inches means reading the 1/4-inch-per-foot column.
Reference: 2024 International Plumbing Code, Section 710.1, Table 710.1(1)
A roof area of 8,000 square feet has a design rainfall rate of 2.5 inches per hour. All of it drains to one horizontal building storm drain sloped at 1/8 inch per foot. What is the minimum size of that storm drain?
Answer: 6 inches
Equation 11-1 gives the flow: 2.5 x 8,000 x 0.0104 = 208 gpm. In the 1/8-inch-per-foot column of Table 1106.2, a 5-inch pipe carries 165 gpm and a 6-inch pipe carries 344 gpm. Since 208 gpm is more than 165, the drain must be 6 inches. Picking 5 inches means using the 1/4-inch-per-foot column (234 gpm).
Reference: 2024 International Plumbing Code, Sections 1106.2 and 1106.2.1, Table 1106.2
Above what static water pressure inside a building must an approved pressure-reducing valve be installed?
Answer: 80 psi
Section 604.8 requires a pressure-reducing valve with strainer (ASSE 1003 or CSA B356) where static pressure in the building exceeds 80 psi. The valve must bring distribution pressure down to 80 psi static or less. Service lines to sill cocks and outside hydrants are excepted.
Reference: 2024 International Plumbing Code, Section 604.8
A T&P relief valve has a 3/4-inch outlet, and its discharge pipe ends over the floor in the water heater room. Where may the end of the discharge pipe be?
Answer: Between 1-1/2 inches and 6 inches above the floor
Section 504.6 requires the discharge pipe to terminate no more than 6 inches above, and at least two times the discharge pipe diameter above, the floor or the waste receptor's flood level rim. Two times 3/4 inch is 1-1/2 inches, so the outlet must be between 1-1/2 and 6 inches above the floor. The 6-to-24-inch range is for water heater pan drains that end outdoors (Section 504.7.2).
Reference: 2024 International Plumbing Code, Section 504.6
A cast-iron drainage and vent system will be air tested. What test pressure and duration are required?
Answer: 5 psi held for 15 minutes
Section 312.3 requires a uniform gauge pressure of 5 psi (or enough to balance a 10-inch column of mercury), held for at least 15 minutes. Any adjustments for ambient temperature changes or gasket seating are made before the test period begins. The 50-psi air test is for water supply piping other than plastic (Section 312.6).
Reference: 2024 International Plumbing Code, Section 312.3
What is the minimum clear space required in front of a water closet to any wall, fixture or door?
Answer: 21 inches
Section 405.3.1 requires at least 21 inches of clearance in front of a water closet, urinal, lavatory or bidet to any wall, fixture or door. The same section requires 15 inches from the fixture centerline to a side wall or obstruction, and 30 inches center to center between adjacent unpartitioned fixtures.
Reference: 2024 International Plumbing Code, Section 405.3.1
An isometric shows the drainage for a single-family home. Second floor: two full bathrooms, each a bathroom group with a 1.6-gpf water closet. First floor: a powder room with a 1.6-gpf private water closet and a lavatory, a domestic kitchen sink (no disposer or dishwasher), and a residential clothes washer standpipe. What is the total drainage fixture unit load on the building drain?
Answer: 18 dfu
Using Table 709.1: two bathroom groups at 5 dfu = 10; powder room water closet 3 + lavatory 1 = 4; kitchen sink 2; residential clothes washer 2. Total = 10 + 4 + 2 + 2 = 18 dfu. Counting the bathroom groups at 6 dfu (the value for water closets over 1.6 gpf) gives 20 dfu. Counting the bathroom groups at 6 and the powder room water closet at its public value of 4 gives 21 dfu.
Reference: 2024 International Plumbing Code, Section 709.1, Table 709.1
Sources
- PSI: Colorado State Plumbing Board Candidate Information Bulletin (opens in a new tab)
- Colorado DORA: Plumbing Board applications and requirements (opens in a new tab)
Questions last verified October 20, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.