Requirements at a glance
| Agency | Colorado State Electrical Board (DORA); exam by PSI |
|---|---|
| Experience | 8,000 hours over at least 4 years (2,000 commercial/industrial) plus 288 classroom hours |
| Exam | 90 scored questions (plus unscored ones) in 240 minutes, 70% (63) to pass |
| Code book | 2026 NEC and a formula page |
| Fees | $78 PSI exam ($73 retest), plus DORA's application fee |
Apprentices with 8,000 hours of experience over at least four years (2,000 commercial or industrial) and 288 classroom hours. Six-year apprentices take the same outline.
Official links
How to get licensed, step by step
Get your hours
Work under a licensed electrician and keep records your supervisors can verify. 8,000 hours over at least 4 years (2,000 commercial/industrial) plus 288 classroom hours.
Register with PSI
Register and schedule online or by phone. The exam fee is good for one year.
Schedule with PSI (Colorado electrical) (opens in a new tab)PSI: Colorado electrical candidate bulletin (opens in a new tab)
Pass the Journeyman exam
90 scored questions (plus unscored ones) in 240 minutes, 70% (63) to pass. The 2026 NEC and a formula page is provided at the test center.
Apply to DORA
After you pass, apply to the State Electrical Board with your experience verification. Passing doesn't guarantee a license until the board approves your hours.
DORA: Electrical Board applications and requirements (opens in a new tab)
How to prepare
- PSI hands you an unmarked code book: no tabs, highlights or notes. Practice with a clean copy and learn the index and the article/chapter layout instead of relying on tabs.
- There's no per-section minimum, so don't get stuck. Skip hard lookups, finish the easy ones, then come back.
- Grounding and bonding is the biggest section (14). Know Article 250 tables 250.66, 250.102(C)(1) and 250.122 cold.
- Motors (6) and transformers (4) together are as big as services: practice Article 430 FLC tables and transformer overcurrent sizing.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2026 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2026 EditionEssential
Provided at the test center (unmarked), with a formula page. Study with your own copy. Load calculations are in the new Article 120.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2026 Edition, and a formula page (both provided at the test center)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 11 | |
| Services, Feeders, and Branch Circuits | 9 | |
| Grounding and Bonding | 14 | |
| Overcurrent Protection | 6 | |
| Conductors and Cables | 8 | |
| Raceways and Boxes | 5 | |
| Special Occupancies | 5 | |
| Special Equipment | 6 | |
| Electrical Devices | 5 | |
| Motors | 6 | |
| Transformers | 4 | |
| Photovoltaics | 2 | |
| Electrical Calculations | 9 |
Exam day details
- Administered by PSI Services for the Colorado State Electrical Board (DORA).
- Fee: $78 to PSI ($73 to retake). The fee is valid for one year. DORA's license application fee is separate.
- 90 scored questions in 240 minutes, plus up to 10 unscored questions with 30 extra minutes. You need 63 correct (70%).
- Since August 1, 2026 the exam is based on the 2026 NEC. You can ask for the 2023 book until December 1, 2026. Load calculations moved to the new Article 120 in 2026.
- PSI provides the code book and formula page. You can't bring your own books or write, highlight or tab the ones provided, so practice finding things in an unmarked code.
- Overall score only: there is no minimum per section.
- No Colorado law questions; the exam is NEC, theory and calculations.
Frequently asked questions
What NEC edition is the Colorado journeyman exam based on?
The 2026 NEC since August 1, 2026. PSI provides the code book at the test center; you can ask for the 2023 book until December 1, 2026.
What's on the Colorado Journeyman Electrician exam?
90 scored questions. Grounding and bonding is the biggest area (14), then general electrical knowledge (11), services, feeders and branch circuits (9) and calculations (9). Motors, transformers and PV add 12 more.
How many hours do I need for a Colorado journeyman license?
8,000 hours of experience over no less than four years, at least 2,000 of them commercial or industrial, plus 288 hours of classroom education documented with a transcript.
Free questions with answers
Show all 10 free questions and answers
In an office building, a panelboard is fed by a 4-wire feeder from the service equipment in the same building. The inspector finds the neutral bar bonded to the panelboard enclosure with the green bonding screw. What does Section 250.24(B) say about this connection?
Answer: Not permitted; on the load side of the service disconnect the neutral may not be bonded to enclosures except where Article 250 allows it
Section 250.24(B) prohibits connecting the grounded conductor to normally non-current-carrying metal parts or equipment grounding conductors, or reconnecting it to ground, on the load side of the service disconnecting means, except where Article 250 specifically allows it (for example 250.30 for separately derived systems). A neutral-to-case bond in a downstream panel puts normal neutral current on the EGCs, raceways and enclosures in parallel with the neutral. The main bonding jumper belongs only at the service equipment (250.28). The panel's rating has nothing to do with it; remove the bonding screw.
Reference: 2026 National Electrical Code (NFPA 70), Section 250.24(B)
A building footing contains more than 20 ft of 1/2-in. rebar encased in 3 in. of concrete, but the footing was poured on a plastic vapor barrier that separates the concrete from the soil. Can this rebar serve as the concrete-encased electrode under Section 250.52(A)(3)?
Answer: No; concrete separated from the soil by a vapor barrier is not in direct contact with the earth
Section 250.52(A)(3) requires the rebar (at least 20 ft of 1/2-in. bar) or a bare copper conductor (not smaller than 4 AWG) to be encased in at least 2 in. of concrete located in a foundation or footing that is in direct contact with the earth. The informational note to 250.52(A)(3) says concrete installed with insulation, vapor barriers, films or similar items separating it from the earth is not in direct contact with the earth. The rebar size and cover are fine, but the vapor barrier disqualifies it. Ordinary steel tie wire is an acceptable way to join rebar, and rebar is one of the two permitted options.
Reference: 2026 National Electrical Code (NFPA 70), Section 250.52(A)(3) and its Informational Note
During an inspection, a molded-case circuit breaker used for branch-circuit protection shows no interrupting rating anywhere on the device. Under Section 240.83(C), what interrupting rating does that mean it has?
Answer: 5,000 A
Section 240.83(C) requires every circuit breaker with an interrupting rating other than 5,000 A to have that rating shown on the breaker. A breaker with no marked interrupting rating is therefore a 5,000-ampere device. Supplementary protectors are exempt from the marking rule, but a branch-circuit breaker is not. Many residential breakers are marked 10,000 A, which is why that is a common wrong answer.
Reference: 2026 National Electrical Code (NFPA 70), Section 240.83(C)
A 480Y/277-volt switchboard faces an energized 480-volt motor control center across the aisle, with exposed or enclosed live parts on both sides of the working space. Using Table 110.26(A)(1), what is the minimum depth of working space?
Answer: 4 ft
The switchboard operates at 277 volts to ground, so it uses the 151-600 volt row of Table 110.26(A)(1). Live parts on both sides of the working space is Condition 3, which requires 4 ft. 3 ft is Condition 1 (nothing grounded or live across the aisle) and 3 1/2 ft is Condition 2 (grounded parts such as a concrete wall across the aisle). Depth is measured from the enclosure front.
Reference: 2026 National Electrical Code (NFPA 70), Section 110.26(A)(1) and Table 110.26(A)(1)
Section 210.8(F) requires GFCI protection for outdoor outlets at dwellings supplied by single-phase branch circuits rated 150 volts or less to ground. Under the 2026 NEC, up to what branch-circuit rating does this apply?
Answer: 60 amperes
The 2026 NEC raised the limit in 210.8(F) from 50 amperes to 60 amperes, so outdoor outlets at dwelling units supplied by single-phase branch circuits rated 150 volts or less to ground and 60 amperes or less need GFCI protection. 50 A was the 2023 limit. 100 A is the three-phase limit used for Class A GFCI in 680.5(B), not 210.8(F).
Reference: 2026 National Electrical Code (NFPA 70), Section 210.8(F)
Type NM cable is run along the side of a basement floor joist to an outlet box. Under Section 334.30, what is the maximum distance from the box to the first fastener, and the maximum spacing between fasteners?
Answer: 12 in.; 4 1/2 ft
Section 334.30 requires Type NM cable to be secured by staples, cable ties, straps, hangers or similar fittings at intervals not exceeding 4 1/2 ft and within 12 in. of every cable entry into an enclosure such as an outlet box. The 6-ft spacing is the rule for Type MC cable in 330.30, not NM. The fittings must be designed and installed so they do not damage the cable.
Reference: 2026 National Electrical Code (NFPA 70), Section 334.30
At a motor fuel dispensing facility, where must the required emergency shutoff devices or electrical disconnects for the fuel dispensing system be located under Section 514.11(A)?
Answer: In approved locations at least 20 ft but not more than 100 ft from the dispensers
Section 514.11(A), revised in 2026 to align with NFPA 30A, requires one or more clearly identified emergency shutoff devices or electrical disconnects in approved locations not less than 20 ft or more than 100 ft from the dispensing devices they serve. Additional devices may be located closer than 20 ft or farther than 100 ft. They must disconnect power to dispensers (other than intrinsically safe circuits), remote pumps, associated power, control and signal circuits, and other equipment in the hazardous locations.
Reference: 2026 National Electrical Code (NFPA 70), Section 514.11(A)
A city is installing 125-volt, 20-ampere nonlocking receptacles at a public park pavilion. Under Section 406.26 in the 2026 NEC, must they be listed tamper-resistant?
Answer: Yes; 406.26 now lists park and recreation areas
Section 406.26 (406.12 in the 2023 NEC) lists locations where 15- and 20-ampere, 125- and 250-volt nonlocking receptacles must be listed tamper-resistant, including dwelling units, schools, child care facilities, and other places where children may be present. The 2026 NEC added park and recreation areas to the list. Outdoor receptacles are not exempt, and the list is not limited to dwellings.
Reference: 2026 National Electrical Code (NFPA 70), Section 406.26
A continuous-duty motor has a nameplate full-load current of 20 A, a service factor of 1.0, and a marked temperature rise of 50°C. Under the basic rule of Section 430.32(A)(1), what is the maximum rating of a separate overload device?
Answer: 23.0 A
Section 430.32(A)(1) sizes separate overload devices from the motor nameplate current: 125 percent for motors with a service factor of 1.15 or more, 125 percent for motors with a marked temperature rise of 40°C or less, and 115 percent for all other motors. This motor has a 1.0 service factor and a 50°C rise, so 20 A x 1.15 = 23.0 A. 25.0 A wrongly uses 125 percent, and 28.0 A is the 140 percent maximum that 430.32(C) allows only when the first selection will not let the motor start or carry the load.
Reference: 2026 National Electrical Code (NFPA 70), Section 430.32(A)(1)
A one-family house of 2,850 ft² is wired with the minimum two 20-ampere small-appliance circuits and a single laundry circuit. Applying the Table 120.45 demand factors under the standard method, what net load results for general lighting plus the small-appliance and laundry circuits?
Answer: 5,520 VA
Section 120.41 sets the dwelling general lighting load at 2 VA/ft² for feeders and services: 2,850 x 2 = 5,700 VA. Section 120.52 adds 1,500 VA for each small-appliance circuit (3,000 VA) and 1,500 VA for the laundry circuit, for a total of 10,200 VA. Table 120.45: first 3,000 VA at 100 percent = 3,000 VA, and the remaining 7,200 VA at 35 percent = 2,520 VA, so the net load is 5,520 VA. 6,518 VA uses the old 3 VA/ft², which in 2026 applies only to counting branch circuits (120.13); 4,995 VA leaves out the laundry circuit; 10,200 VA skips the demand factors.
Reference: 2026 National Electrical Code (NFPA 70), Section 120.41, Section 120.52, and Table 120.45