Arizona licensing exam

Arizona R-37 Residential Plumbing Contractor Exam: Practice Test & Licensing Guide

The PSI trade exam for Arizona's R-37R residential plumbing license (R-37 adds solar): 100 questions on the 2018 IPC and IFGC, septic systems and home sprinklers, open book.

Questions
100
Time limit
4 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Drainage, Waste and Vents

A 2-inch horizontal waste line serves a laundry tray and lavatory in a house. What is the minimum slope the IPC allows for this pipe?

Requirements at a glance

AgencyArizona Registrar of Contractors (ROC); trade exam by PSI
Exams100 questions, 240 minutes, 70%, plus the online Statutes and Rules Exam (SRE)
Books allowed2018 IPC, IFGC and IMC, NFPA 13/13D/13R, ADEQ on-site wastewater rules, 29 CFR 1926
Fees$66 PSI trade exam + $61 SRE, plus ROC license fees and bond

Qualifying parties for an Arizona R-37R Plumbing (Residential) license, or R-37 Plumbing Including Solar, which adds a separate solar portion.

How to get licensed, step by step

  1. Pick your classification and qualifying party

    Find your classification on the ROC's list. The qualifying party (an owner or regular employee of the business) must have the required trade experience and takes the exams for the business.

    Arizona ROC: License classifications (opens in a new tab)

  2. Pass the Statutes and Rules Exam (SRE)

    Buy the ROC's online SRE course and exam through GMetrix ($61), work through the course, then take the final exam. 70% to pass, one attempt per purchase.

    Buy the Statutes and Rules Exam (GMetrix) (opens in a new tab)

  3. Schedule the R-37R trade exam with PSI

    Book online with PSI ($66, or $116 for two exams). Bring the allowed references, bound and tabbed. If you fail, wait 30 days to retake.

    Schedule with PSI (Arizona contractors) (opens in a new tab)PSI content outline: R-37R Plumbing (Residential) (opens in a new tab)

  4. Apply to the ROC

    Submit your application with your passing score reports within two years of passing, plus the license bond, fees and business documents the ROC asks for.

    Arizona ROC: Applying for a license (opens in a new tab)

How to prepare

  • Bring the exact code editions on PSI's list. Arizona's trade exams use older editions (2017 NEC, 2018 I-codes); a newer book gives some wrong answers.
  • Bind or spiral any printed references, and tab them with permanent tabs before exam day. Sticky notes are removed at check-in.
  • Practice finding answers fast. On a 100-question, 4-hour exam you have 2.4 minutes per question, and some of that goes to unscored items.
  • Septic and sewer is 10 questions, from ADEQ's on-site wastewater rules. Print and tab them.
  • Practice reading isometric drawings: count DFUs, size the drain and check each vent.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Plumbing Code (IPC), 2018; International Fuel Gas Code (IFGC), 2018; International Mechanical Code (IMC), 2018 (allowed in the exam room)
  • NFPA 13 (2016), NFPA 13D (2007) and NFPA 13R (2007) sprinkler standards (allowed in the exam room)
  • ADEQ on-site wastewater rules, Arizona Administrative Code Title 18, Chapter 9 (allowed in the exam room)
  • 29 CFR Part 1926, OSHA Construction (allowed in the exam room)
  • Mathematics for Plumbers and Pipefitters; IPT's Pipe Trades Handbook; Modern Hydronic Heating; Arizona 811 Blue Stake brochure (not allowed in the room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Drainage, Waste and Vents16
Indirect Waste4
Water Supply Systems13
Backflow Prevention5
Roof Drains and Storm Drainage5
Plumbing Fixtures and Water Heaters7
General Knowledge and Regulations10
Specialty Plumbing, Interceptors and Traps5
Isometric Analysis5
Fuel Gas10
Septic and Sewer10
Fire Sprinklers5
Excavation5

Exam day details

  • Administered by PSI Services for the Arizona Registrar of Contractors (ROC).
  • Fee: $66 to PSI ($116 for two exams taken together). The ROC license application fee is separate.
  • 100 scored questions in 240 minutes, 70% to pass.
  • The R-37 (including solar) license adds a separate solar exam portion (PSI charges $40 for the solar portion alone). Our practice test covers the main plumbing exam.
  • Open book: bring your own bound copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them during the exam.
  • PSI adds 5 to 10 unscored trial questions, which count against your time.
  • If you fail, wait 30 days to retake; after a third failure the wait is 90 days. Submit your ROC application within two years of passing.
  • You also need Arizona's Statutes and Rules Exam (SRE), taken online through the ROC. The ROC can waive the trade exam if you were the qualifying party on a license in the same classification in the last five years.

Frequently asked questions

What's on the Arizona R-37 residential plumbing exam?

100 questions: drainage, waste and vents 16, water supply 13, fuel gas 10, septic and sewer 10, general knowledge and regulations 10, fixtures and water heaters 7, and smaller sections on isometric analysis, backflow, storm drainage, interceptors, sprinklers, excavation and indirect waste.

What's the difference between R-37 and R-37R?

R-37 includes solar water heating and adds a solar portion to the exam. R-37R is plumbing only.

What is isometric analysis on the plumbing exam?

Questions based on a drawing of a piping layout: reading the fittings, sizing the pipes and checking the venting. Our versions describe the layout in words.

Free questions with answers

Show all 10 free questions and answers
  1. A 2-inch horizontal waste line serves a laundry tray and lavatory in a house. What is the minimum slope the IPC allows for this pipe?

    Answer: 1/4 inch per foot

    Table 704.1 requires 1/4 inch per foot (2 percent) for horizontal drainage pipe 2-1/2 inches or smaller. 1/8 inch per foot applies to 3- through 6-inch pipe, and 1/16 inch per foot to 8-inch and larger. Look up the slope in Table 704.1, then use the matching column of Table 710.1(1) when sizing a building drain.

    Reference: 2018 International Plumbing Code, Section 704.1 and Table 704.1

  2. A lavatory has a 1-1/2-inch trap and a fixture drain sloped at 1/4 inch per foot. What is the maximum developed length from the trap weir to the vent fitting?

    Answer: 6 feet

    Table 909.1 allows 6 feet for a 1-1/2-inch trap at 1/4 inch per foot. The other values in the table are 5 feet for a 1-1/4-inch trap, 8 feet for a 2-inch trap, 12 feet for a 3-inch trap and 16 feet for a 4-inch trap. Self-siphoning fixtures such as water closets are exempt from the limit.

    Reference: 2018 International Plumbing Code, Section 909.1 and Table 909.1

  3. How high above its trap weir must a clothes washer standpipe extend?

    Answer: At least 18 inches and no more than 42 inches

    Section 802.4.3 requires standpipes to be individually trapped and to extend at least 18 inches but no more than 42 inches above the trap weir, with access for rodding. Too short a standpipe can overflow when the washer pumps out. Too tall a standpipe lets the discharge build enough momentum to siphon the trap. The 30-inch figure is for a standpipe that also receives a laundry tray (Section 802.4.3.1).

    Reference: 2018 International Plumbing Code, Section 802.4.3

  4. A PEX water service will run parallel to a building sewer made of a material NOT listed in Table 702.2, so the two may not share a trench. What minimum horizontal separation is required between them?

    Answer: 5 feet of undisturbed or compacted earth

    Section 603.2 lets a water service share a trench with the building sewer only when the sewer is made of a material listed in Table 702.2. Otherwise the two must be at least 5 feet apart horizontally, with undisturbed or compacted earth between them. The 12-inch figure is the vertical clearance in the separate exception for a water service running above the sewer.

    Reference: 2018 International Plumbing Code, Section 603.2

  5. A new house has a multipurpose fire sprinkler system that is part of the domestic water distribution piping and has no fire department connection. What backflow isolation does the IPC require between the potable supply and the sprinkler piping?

    Answer: None; isolation of the water supply is not required for this type of system

    Section 608.17.4 normally requires a double check, double check fire protection or reduced pressure principle fire protection assembly on the potable supply to sprinkler systems. An exception says isolation is not required where the sprinkler system is installed as part of the water distribution system under the code and has no fire department connection. Section 608.17.4.1 still requires protection where antifreeze or chemical additives are used.

    Reference: 2018 International Plumbing Code, Section 608.17.4, Exception 1

  6. A section of a house roof has a projected area of 1,800 sq ft and drains to one round downspout (vertical leader). The design 100-year, 1-hour rainfall rate is 3 inches per hour. Using 0.0104 gpm per square foot per inch of rainfall and Table 1106.3, what is the minimum round leader size?

    Answer: 3 inches

    Flow = 1,800 sq ft x 3 in/hr x 0.0104 = 56.2 gpm. In Table 1106.3, a 2-1/2-inch round leader carries 54 gpm, which is too small. A 3-inch leader carries 92 gpm, so 3 inches is the minimum. The 2-1/2-inch choice is the common mistake of picking the size whose capacity is closest to the flow instead of the first size that meets or exceeds it. Section 1106.1 bases sizing on the 100-year hourly rainfall rate.

    Reference: 2018 International Plumbing Code, Sections 1106.1 and 1106.3, Table 1106.3

  7. What is the minimum distance from the centerline of a water closet to an adjacent vanity cabinet, and the minimum clear space in front of the water closet?

    Answer: 15 inches to the side; 21 inches in front

    Section 405.3.1 says a water closet, urinal, lavatory or bidet may not be set closer than 15 inches from its center to any side wall, partition, vanity or other obstruction. It also requires at least 21 inches of clearance in front of the fixture to any wall, fixture or door. The 12-inch side clearance applies only to an accessible children's water closet.

    Reference: 2018 International Plumbing Code, Section 405.3.1

  8. A DWV system in a two-story house is water tested in sections. What is the minimum head of water on each section, and how long must it hold?

    Answer: 10-foot head for 15 minutes

    Section 312.2 says sections may not be tested with less than a 10-foot head of water. When testing successive sections, at least the upper 10 feet of the preceding section must be tested again, so every joint except the top 10 feet of the system sees at least a 10-foot head. The pressure must hold for at least 15 minutes. 30 minutes is not in this section.

    Reference: 2018 International Plumbing Code, Section 312.2

  9. A new natural gas piping system in a house will run at 7 inches water column (about 0.25 psi). What is the minimum test pressure?

    Answer: 3 psig

    Section 406.4.1 requires a test pressure of at least 1-1/2 times the proposed maximum working pressure, but never less than 3 psig regardless of design pressure. 1.5 x 0.25 psi = 0.375 psig, which is below 3 psig, so 3 psig governs. 0.375 psig is the result of forgetting the 3-psig floor.

    Reference: 2018 International Fuel Gas Code, Section 406.4.1

  10. Under the ADEQ on-site wastewater rules, what is the minimum setback from a septic system (including reserve area) to a house, where the house includes its covered porch and steps?

    Answer: 10 feet

    The setback table in R18-9-A312(C) sets 10 feet from a building. The special provision says the building includes porches, decks (including pool decks), steps, breezeways, roofed patios, carports, covered walks and similar structures, so you measure from the porch, not the wall. 5 feet is the setback to driveways, swimming pool excavations and most property lines.

    Reference: Arizona Administrative Code, Title 18, Chapter 9 (ADEQ on-site wastewater rules), R18-9-A312(C), setback table item 1

Sources

Questions last verified October 20, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.