Requirements at a glance
| Agency | Arizona Registrar of Contractors (ROC); trade exam by PSI |
|---|---|
| Exams | 110 questions, 240 minutes, 70%, plus the online Statutes and Rules Exam (SRE) |
| Books allowed | 2017 NEC, NFPA 72-2016 and 29 CFR 1926 |
| Fees | $66 PSI trade exam + $61 SRE, plus ROC license fees and bond |
Qualifying parties for an Arizona R-11 Electrical (Residential) contractor license.
Official links
How to get licensed, step by step
Pick your classification and qualifying party
Find your classification on the ROC's list. The qualifying party (an owner or regular employee of the business) must have the required trade experience and takes the exams for the business.
Pass the Statutes and Rules Exam (SRE)
Buy the ROC's online SRE course and exam through GMetrix ($61), work through the course, then take the final exam. 70% to pass, one attempt per purchase.
Buy the Statutes and Rules Exam (GMetrix) (opens in a new tab)
Schedule the R-11 trade exam with PSI
Book online with PSI ($66, or $116 for two exams). Bring the allowed references, bound and tabbed. If you fail, wait 30 days to retake.
Schedule with PSI (Arizona contractors) (opens in a new tab)PSI content outline: R-11 Electrical (Residential) (opens in a new tab)
Apply to the ROC
Submit your application with your passing score reports within two years of passing, plus the license bond, fees and business documents the ROC asks for.
How to prepare
- Bring the exact code editions on PSI's list. Arizona's trade exams use older editions (2017 NEC, 2018 I-codes); a newer book gives some wrong answers.
- Bind or spiral any printed references, and tab them with permanent tabs before exam day. Sticky notes are removed at check-in.
- Practice finding answers fast. On a 100-question, 4-hour exam you have 2.4 minutes per question, and some of that goes to unscored items.
- Services, feeders and branch circuits (18), grounding and bonding (16) and raceways and boxes (15) are almost half the exam. Practice dwelling load calcs (220 Parts III and IV) and box fill (314.16).
- Photovoltaics is 10 questions: rooftop solar is common in Arizona, so know Article 690 (2017).
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2017 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code, 2017 EditionEssential
The edition PSI's Arizona outline lists. Newer editions renumber key tables and rules.
NFPA 72: National Fire Alarm and Signaling Code, 2016 Edition
Allowed in the room; source of the fire alarm questions.
29 CFR 1926 (OSHA Construction Standards), sections on your reference list
Trenching, scaffolds, fall protection and ladders. Print just the listed sections.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code, 2017 (allowed in the exam room)
- NFPA 72: National Fire Alarm and Signaling Code, 2016 (allowed in the exam room)
- 29 CFR Part 1926, OSHA Construction (allowed in the exam room)
- Ugly's Electrical References; Photovoltaic Systems, Dunlop (not allowed in the room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 6 | |
| Services, Feeders and Branch Circuits | 18 | |
| Grounding and Bonding | 16 | |
| Conductors and Cables | 12 | |
| Raceways and Boxes | 15 | |
| Special Occupancies and Equipment | 3 | |
| Electrical Devices | 2 | |
| Motors | 3 | |
| Low Voltage | 2 | |
| Lighting | 6 | |
| Fire Detection and Alarm Systems | 5 | |
| Safety | 5 | |
| Overcurrent Protection | 7 | |
| Photovoltaics | 10 |
Exam day details
- Administered by PSI Services for the Arizona Registrar of Contractors (ROC).
- Fee: $66 to PSI ($116 for two exams taken together). The ROC license application fee is separate.
- 110 scored questions in 240 minutes, 70% to pass.
- The exam uses the 2017 NEC. Bring the 2017 code book.
- You can take the NASCLA Accredited Trade Examination for Residential Electrical Contractors instead.
- Open book: bring your own bound copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them during the exam.
- PSI adds 5 to 10 unscored trial questions, which count against your time.
- If you fail, wait 30 days to retake; after a third failure the wait is 90 days. Submit your ROC application within two years of passing.
- You also need Arizona's Statutes and Rules Exam (SRE), taken online through the ROC. The ROC can waive the trade exam if you were the qualifying party on a license in the same classification in the last five years.
Frequently asked questions
What's on the Arizona R-11 exam?
110 questions, weighted toward dwellings: services, feeders and branch circuits 18, grounding and bonding 16, raceways and boxes 15, conductors and cables 12 and photovoltaics 10.
R-11 or CR-11: which do I need?
R-11 covers residential electrical work only. CR-11 (dual) and C-11 (commercial) cover commercial work and use a different exam with more on motors and special occupancies.
Which NEC edition does the R-11 exam use?
The 2017 NEC, according to PSI's current content outline.
Free questions with answers
Show all 10 free questions and answers
A new one-family dwelling is being wired under the 2017 NEC. What is the minimum rating of the service disconnecting means?
Answer: 100 amperes
Section 230.79(C) requires the service disconnecting means for a one-family dwelling to be rated at least 100 amperes, 3-wire. The 60-ampere minimum in 230.79(D) applies to other installations, not one-family dwellings. Larger services (150 or 200 A) are common design choices, not the code minimum.
Reference: NFPA 70, National Electrical Code, 2017, 230.79(C)
A 2,000 sq ft dwelling has the two required small-appliance circuits and one laundry circuit. Using the standard method, what is the general lighting, small-appliance and laundry load after applying the Table 220.42 demand factors?
Answer: 5,625 VA
Step 1: lighting 2,000 sq ft x 3 VA = 6,000 VA (Table 220.12). Step 2: add 1,500 VA for each small-appliance circuit and 1,500 VA for the laundry circuit (220.52(A) and (B)): 6,000 + 3,000 + 1,500 = 10,500 VA. Step 3: Table 220.42 for dwellings takes the first 3,000 VA at 100% and the next 7,500 VA at 35%: 3,000 + 2,625 = 5,625 VA. 10,500 VA forgets the demand factor; 3,675 VA applies 35% to the whole load; 6,675 VA adds the first 3,000 VA but then applies 35% to the full 10,500 VA instead of the remaining 7,500 VA.
Reference: NFPA 70, National Electrical Code, 2017, 220.42, Table 220.42, 220.52(A), 220.52(B)
A one-family dwelling has a 200-ampere service, and the service-entrance conductors carry the entire dwelling load. Using 310.15(B)(7) and the 75 C column of Table 310.15(B)(16), what is the smallest copper service-entrance conductor permitted?
Answer: 2/0 AWG
Section 310.15(B)(7)(1) permits dwelling service-entrance conductors for a 100-400 A service supplying the entire load to have an ampacity of not less than 83% of the service rating: 200 x 0.83 = 166 A. In the 75 C copper column of Table 310.15(B)(16), 1/0 AWG is 150 A (too small) and 2/0 AWG is 175 A, so 2/0 AWG copper is the minimum. 3/0 AWG (200 A) is what you get if you skip the 83% rule.
Reference: NFPA 70, National Electrical Code, 2017, 310.15(B)(7), Table 310.15(B)(16)
A single ground rod is the only electrode at a dwelling, and its resistance to earth has not been measured. What does 250.53(A) require?
Answer: A supplemental electrode, at least 6 ft from the first rod
Section 250.53(A)(2) requires a single rod, pipe or plate electrode to be supplemented by an additional electrode unless it is shown to have a resistance to earth of 25 ohms or less. Section 250.53(A)(3) requires the two electrodes to be at least 6 ft apart. Since no measurement was made, the supplemental electrode is required. 10 ft is not the spacing rule, and a second rod within 3 ft would be too close.
Reference: NFPA 70, National Electrical Code, 2017, 250.53(A)(2), 250.53(A)(3)
A dwelling service has 2/0 AWG copper service-entrance conductors. What is the minimum size of the copper bonding jumper for the interior metal water piping system?
Answer: 4 AWG
Section 250.104(A)(1) of the 2017 NEC requires the metal water piping bonding jumper to be sized from Table 250.102(C)(1), based on the size of the service-entrance conductors. For copper service conductors of 2/0 or 3/0 AWG, the table gives 4 AWG copper. 6 AWG is the row for 1 or 1/0 AWG copper; 8 AWG is for 2 AWG and smaller.
Reference: NFPA 70, National Electrical Code, 2017, 250.104(A)(1), Table 250.102(C)(1)
Five 12/2 NM-B cables (each with two current-carrying conductors) pass without spacing through the same bored holes in wood framing that will be sealed with fire-stopping caulk. Under 334.80, what is the adjusted ampacity of each 12 AWG conductor?
Answer: 15 A
Section 334.80 requires Table 310.15(B)(3)(a) adjustment where more than two NM cables with two or more current-carrying conductors pass through the same opening that is sealed. Five cables x 2 = 10 current-carrying conductors, so the factor is 50%. NM conductors are 90 C rated and the derating may start from the 90 C column: 12 AWG copper = 30 A; 30 x 0.50 = 15 A. The final ampacity may not exceed the 60 C value (20 A), and 15 A is below that. 21 A uses the 70% factor for 7-9 conductors.
Reference: NFPA 70, National Electrical Code, 2017, 334.80, Table 310.15(B)(3)(a), Table 310.15(B)(16)
A device box will contain two 12/2 NM cables with ground (all conductors 12 AWG), one duplex receptacle, and internal cable clamps. Using 314.16(B), what is the minimum box volume?
Answer: 18.00 cu in
Count per 314.16(B): four insulated 12 AWG conductors = 4; all equipment grounding conductors together = 1 (314.16(B)(5)); internal clamps = 1 (314.16(B)(2)); the receptacle yoke = 2 (314.16(B)(4)). Total 8 volumes x 2.25 cu in (Table 314.16(B) for 12 AWG) = 18.00 cu in. 20.25 cu in counts each ground separately; 15.75 cu in counts the device as one.
Reference: NFPA 70, National Electrical Code, 2017, 314.16(B), Table 314.16(B)
A new dishwasher is installed in a dwelling kitchen. Under the 2017 NEC, what protection is required for the outlet that supplies it?
Answer: GFCI protection, under 210.8(D)
The 2017 NEC added 210.8(D), which requires GFCI protection for outlets that supply dishwashers in dwelling unit locations, whether hard-wired or cord-and-plug connected and regardless of distance from the sink. The 6-ft sink rule in 210.8(A)(7) applies to receptacles, but the dishwasher rule does not depend on distance. Kitchen outlets also need AFCI protection under 210.12(A), but that does not replace the GFCI requirement.
Reference: NFPA 70, National Electrical Code, 2017, 210.8(D)
A residential PV source circuit has 13 crystalline silicon modules in series, each with a rated open-circuit voltage (Voc) of 38.4 V. The lowest expected ambient temperature is -6 C. Using Table 690.7(A), what is the maximum PV system voltage?
Answer: 569.1 V
Section 690.7(A) requires the sum of the series-connected modules' rated Voc to be corrected for the lowest expected ambient temperature; for crystalline modules Table 690.7(A) may be used. String Voc = 13 x 38.4 = 499.2 V. Table 690.7(A) gives 1.14 for -6 to -10 C: 499.2 x 1.14 = 569.1 V. 559.1 V uses the -1 to -5 C factor (1.12); 499.2 V is uncorrected.
Reference: NFPA 70, National Electrical Code, 2017, 690.7(A), Table 690.7(A)
A 120/240-volt residential panelboard in a garage faces a concrete block wall (a grounded surface), with exposed live parts only on the panel side. Using Table 110.26(A)(1), what is the minimum depth of working space in front of the panel?
Answer: 3 ft
Table 110.26(A)(1) is based on nominal voltage to ground. A 120/240-volt single-phase system is 120 V to ground, which falls in the 0-150 V row, where Conditions 1, 2 and 3 all require 3 ft. The 3 1/2 ft value for Condition 2 (live parts on one side, grounded parts such as concrete on the other) applies only at 151-600 V to ground, so it is the tempting wrong answer here.
Reference: NFPA 70, National Electrical Code, 2017, 110.26(A)(1), Table 110.26(A)(1)
Sources
- PSI: R-11 Electrical (Residential) content outline (PDF) (opens in a new tab)
- PSI: Arizona ROC Candidate Information Bulletin (Feb 2026) (opens in a new tab)
- Arizona ROC: Applying for a license (opens in a new tab)
Questions last verified October 19, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.