Requirements at a glance
| Agency | Virginia Department of Professional and Occupational Regulation (DPOR), Board for Contractors; exams by PSI |
|---|---|
| Experience | 8 years of experience alone, or school hours plus 4 to 7 years, an associate degree plus 2 years or an engineering bachelor's degree plus 1 year |
| Exam | journeyman electrician exam: 70 items, 210 minutes, 49 correct |
| Books allowed | 2020 NEC and the American Electricians' Handbook, 16th Edition |
| Fees | $100 to PSI; $150 original DPOR license |
Electricians applying to the Virginia Board for Contractors for a journeyman electrician license after meeting the education and experience requirements.
Official links
How to get licensed, step by step
Check the education and experience rules
You must be 18 and document training and work experience. The requirements depend on the license level; see 18VAC50-30-39.
Virginia Administrative Code 18VAC50-30 (tradesman regulations) (opens in a new tab)Virginia DPOR: Tradesmen licensing (opens in a new tab)
Apply to the Board for Contractors
The Board reviews your application first and approves you to take the exam. Disclose any convictions.
Register and schedule the journeyman electrician exam with PSI
After approval, pay PSI and book a seat. Your eligibility is good for one year and you can retake within that year.
Schedule with PSI (Virginia DPOR exams) (opens in a new tab)
Get licensed
Send your passing result to the Board with the license fee ($150 for an original journeyman or master license; additional designations $105). Trade licenses run three years and need continuing education (3 hours per designation) on the current code edition.
Virginia DPOR: Tradesmen licensing (opens in a new tab)Virginia Administrative Code 18VAC50-30 (tradesman regulations) (opens in a new tab)
How to prepare
- Bring the editions on PSI's list: the 2020 NEC for electrical and the 2021 IPC, IMC and IFGC (Virginia Plumbing, Mechanical and Fuel Gas Codes) for plumbing, HVAC and gas. Virginia's 2024 code cycle (NEC 2023 and the 2024 I-codes) is tentatively set to take effect in October 2027; until PSI publishes a new bulletin, code questions use the 2021 USBC editions.
- Exam fees may change: a rule effective 3/11/2026 raised the Board's exam fee caps, though DPOR still lists $100 for journeyman and $125 for master exams. Confirm the fee with PSI when you register.
- Tab your books before exam day with permanent tabs. You can highlight, underline and index, but you can't write in them, use removable tabs or bring loose papers or study guides.
- Ten items on every journeyman and master exam (nine on the residential exams) come from the Board's rules, 18VAC50-30. They are easy points if you read the regulation once.
- Raceways and boxes (8), services and branch circuits (7), grounding and bonding (7) and conductors (7) are 29 of the 70 items. Tab Articles 210 to 250, 300 to 314 and Chapter 9.
- Motors and controls and utilization equipment are 5 items each: Articles 430, 422 and 440.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC and 18VAC50-30. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2020 EditionEssential
Allowed in the exam room. Code questions are based only on the 2020 edition. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
American Electricians' Handbook, 16th Edition (McGraw-Hill)
Allowed in the exam room. Fundamentals, formulas and installation practice.
Board for Contractors Individual License and Certification Regulations (18VAC50-30)Essential
Free online. Ten items on every journeyman and master exam come from this regulation.
Virginia Administrative Code 18VAC50-30 (tradesman regulations) (opens in a new tab)
Official reference list (as published by the testing agency)
- National Electrical Code (NFPA 70), 2020 edition; the Virginia Electrical Code adopts it (code questions use only the listed edition)
- American Electricians' Handbook, 16th Edition
- Board for Contractors Individual License and Certification Regulations (18VAC50-30)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Standards of Practice | 3 | |
| Standards of Conduct | 2 | |
| Renewal and Reinstatement | 2 | |
| Definitions | 1 | |
| Qualification for Licensure | 1 | |
| Revocation | 1 | |
| General Electrical Knowledge | 3 | |
| Requirements for Electrical Installations | 3 | |
| Electrical-Electronic Fundamentals | 2 | |
| Services Feeders and Branch Circuits | 7 | |
| Service and Feeder Requirements | 2 | |
| Grounding and Bonding | 7 | |
| Conductors and Cables | 7 | |
| Raceways and Boxes | 8 | |
| Special Occupancies | 3 | |
| Special Equipment | 2 | |
| Electrical Signs and Outline Lighting | 1 | |
| Motors and Controls | 5 | |
| Utilization Equipment | 5 | |
| Lighting | 2 | |
| General Low Voltage | 1 | |
| Communication Systems | 1 | |
| Fire Detection and Alarm | 1 |
Exam day details
- Administered by PSI Services for the Virginia Department of Professional and Occupational Regulation (DPOR), Board for Contractors.
- Fee: $100 to PSI per exam, not refundable or transferable and valid for one year. DPOR application and license fees are separate.
- 70 items in 210 minutes; 49 correct (70%) to pass.
- The PSI bulletin (1/14/2025) lists the 2020 NEC (the 2017 edition was also accepted until 5/1/2025). Code questions are based only on the listed edition. Check the current bulletin for the edition on your test date.
- Eligibility: 8 years of experience alone, or school hours plus fewer years (for example 240 hours of school plus 4 years), or an associate degree plus 2 years or an engineering bachelor's degree plus 1 year. The Board decides; see 18VAC50-30-39.
- Open book: bring your own bound copies of the listed references. You may highlight, underline and index them beforehand and add permanent tabs, but removable tabs, loose papers, writing and study guides are not allowed.
- PSI may add unscored experimental questions to the exam.
- Exam fees may change: a rule effective 3/11/2026 raised the Board's exam fee caps, though DPOR still lists $100 (journeyman) and $125 (master). Confirm the fee with PSI when you register.
- The Board for Contractors must approve your application first (education and experience); then you pay and register with PSI. Your exam eligibility is good for one year and you can retake within that year.
- Every Virginia tradesman exam includes 10 items on the Board's rules (18VAC50-30): standards of practice, standards of conduct, renewal and reinstatement, definitions, qualification for licensure and revocation.
Note: These facts come from the PSI bulletin dated 1/14/2025; no newer bulletin was found. The 2021 Virginia USBC (NEC 2020 and the 2021 I-codes) is in force now. Virginia's 2024 code cycle (NEC 2023 and the 2024 I-codes) is tentatively scheduled to take effect in October 2027, and PSI will likely update its bulletin then; that date is not confirmed. Check the current PSI bulletin before you test.
Frequently asked questions
How many questions are on the Virginia journeyman electrician exam?
70 items in 210 minutes, and you need 49 correct. Ten items cover the Board's rules (18VAC50-30); the rest cover the NEC and electrical knowledge.
Which books can I bring?
The 2020 NEC and the American Electricians' Handbook, 16th Edition. The exam is open book: highlight and add permanent tabs, but don't write in them.
Is there a waiting period to retake?
Your exam eligibility lasts one year and you can retake as often as needed within it. Check the current PSI bulletin for any waiting rule.
Free questions with answers
Show all 10 free questions and answers
A Virginia tradesman holds a license with only a journeyman electrician designation and asks the Board to delete that designation. What is the effect?
Answer: The license is terminated because it had only one designation
Under 18VAC50-30-150 C, a regulant seeking to delete a designation must provide a signed statement listing it. If the regulant has only one trade or level designation, deleting it terminates the license.
Reference: Virginia Board for Contractors Tradesman Rules, 18VAC50-30, 18VAC50-30-150(C)
A 120/240-volt service uses 300 kcmil copper service-entrance conductors, and the grounding electrode conductor runs to a metal underground water pipe. Using Table 250.66, what is the minimum copper grounding electrode conductor size?
Answer: 2 AWG, because 300 kcmil falls in the over 3/0 through 350 kcmil row
Table 250.66 is entered with the size of the largest ungrounded service-entrance conductor. For copper, over 3/0 AWG through 350 kcmil calls for 2 AWG; 2/0 or 3/0 calls for 4 AWG; over 350 through 600 kcmil calls for 1/0 AWG. The grounding conductor is never required to equal the service conductor size.
Reference: NFPA 70, National Electrical Code, 2020, Table 250.66
A branch circuit will serve a 40-ampere continuous load, and the breaker is not marked for operation at 100 percent of its rating. What is the minimum standard breaker size?
Answer: 50 amperes
A breaker not rated for continuous operation must be at least 125 percent of the continuous load plus 100 percent of any noncontinuous load (210.20(A)). 40 A x 1.25 = 50 A, which is a standard rating.
Reference: NFPA 70, National Electrical Code, 2020, 210.20(A)
Ten current-carrying 12 AWG THHN copper conductors share one conduit at a 30 C ambient. Table 310.16 gives 30 amperes for 12 AWG at 90 C. What is the adjusted ampacity of each conductor?
Answer: 15 amperes
Ten through twenty current-carrying conductors in a raceway take a 50 percent adjustment factor (Table 310.15(C)(1)): 30 x 0.50 = 15 A. The 80 percent factor is for four to six conductors and 70 percent is for seven to nine.
Reference: NFPA 70, National Electrical Code, 2020, Table 310.15(C)(1)
A straight pull through a pull box uses a 2-inch conduit as the largest raceway. What is the minimum length of the box in the direction of the conductor pull?
Answer: 16 inches
For a straight pull in a box with conductors of 6 AWG or larger, the length must be at least 8 times the trade size of the largest raceway: 8 x 2 = 16 in. The 6 times multiplier applies to angle pulls.
Reference: NFPA 70, National Electrical Code, 2020, 314.28(A)(1)
The available fault current at the line terminals of a new 120/240-volt panelboard is 18,000 amperes. Which breaker rating is acceptable for an installed branch breaker?
Answer: A breaker with a 22,000-ampere interrupting rating at 240 volts
110.9 requires equipment intended to interrupt current at fault levels to have an interrupting rating, at nominal circuit voltage, at least equal to the available fault current at its line terminals. 22,000 A at 240 V exceeds 18,000 A; the others are below it, or rated only for 120 V.
Reference: NFPA 70, National Electrical Code, 2020, 110.9
A 480Y/277-volt panelboard has exposed live parts behind its open door. A grounded concrete wall is directly opposite across the working space, and there are no live parts on that wall. Using Table 110.26(A)(1), what is the minimum depth of working space?
Answer: 3 feet 6 inches (Condition 2)
The table is entered with the voltage to ground, 277 V, so the 151-600 V row applies. Live parts on one side and a grounded part on the other is Condition 2: 3 ft 6 in. Condition 1 (3 ft) has no grounded parts opposite, and Condition 3 (4 ft) has live parts on both sides.
Reference: NFPA 70, National Electrical Code, 2020, 110.26(A)(1); Table 110.26(A)(1)
A location where ignitable concentrations of flammable gases or vapors can exist under normal operating conditions is classified as what?
Answer: Class I, Division 1
500.5(B)(1) defines Class I, Division 1 as a location where ignitable concentrations of flammable gases or vapors exist under normal operating conditions. Division 2 locations have them only under abnormal conditions, and Classes II and III cover dust and fibers.
Reference: NFPA 70, National Electrical Code, 2020, 500.5(B)(1)
A single continuous-duty, 460-volt, three-phase motor has a Table 430.250 full-load current of 34 amperes. What is the minimum ampacity of the branch-circuit conductors?
Answer: 42.5 amperes
430.22 requires conductors to a single continuous-duty motor to have an ampacity of at least 125 percent of the full-load current from the table: 34 x 1.25 = 42.5 A. The table value, not the nameplate, is used for sizing the conductors.
Reference: NFPA 70, National Electrical Code, 2020, 430.22; Table 430.250
A built-in dishwasher is to be cord-and-plug connected. What cord length does the NEC require, measured from the face of the attachment plug to the plane of the rear of the appliance?
Answer: 3 feet to 6-1/2 feet
422.16(B)(2) requires the cord of a built-in dishwasher or trash compactor to be at least 0.9 m (3 ft) and not more than 2.0 m (6-1/2 ft) long, measured from the face of the attachment plug to the plane of the rear of the appliance, with the receptacle in the space occupied by the appliance or adjacent to it. The 18 in. to 36 in. range is for in-sink waste disposers (422.16(B)(1)); the older 3 ft to 4 ft limit was dropped before the 2020 edition.
Reference: NFPA 70, National Electrical Code, 2020, 422.16(B)(2)
Sources
- PSI: Virginia Individual License and Certification Candidate Information Bulletin (1/14/2025) (opens in a new tab)
- Virginia DPOR: Tradesmen licensing (opens in a new tab)
- Virginia Administrative Code 18VAC50-30 (tradesman regulations) (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.