Requirements at a glance
| Agency | Vermont Division of Fire Safety (Electricians' Licensing Board); exam by Prov |
|---|---|
| Exam | 105 questions, 5 hours, open book, 70% to pass |
| Experience | Journeyman license for 2 years or comparable experience accepted by the Board |
| Books allowed | 2023 NEC; Ugly's Electrical References (2020); 2025 Vermont Electrical Safety Rules; 26 V.S.A. ch. 15 |
| Fees | $80 to Prov; Division application and license fees are separate |
Electricians applying to the Vermont Division of Fire Safety (Electricians' Licensing Board) for a master license, who hold a journeyman license for 2 years or have comparable experience the Board accepts. State law (26 V.S.A. 905(b)) also has the master exam cover lightning rods, fire alarms and fire detection.
Official links
How to get licensed, step by step
Meet the experience requirement
Hold a journeyman license for 2 years or have comparable experience the Board accepts. Check the Division's page for the current requirement.
Vermont Division of Fire Safety: electrical licensing (opens in a new tab)26 V.S.A. chapter 15 (electricians) (opens in a new tab)
Apply to the Division of Fire Safety
Send the application and fee to Trade Licensing in Waterbury (802-479-7564). The Division confirms your eligibility and, once the Board approves you, sends your details to Prov. Check its page for current forms and fees.
Vermont Division of Fire Safety: electrical licensing (opens in a new tab)
Schedule with Prov
Once the Board approves you, it sends your details to Prov. Schedule at provexam.com/scheduler (sign in with your email and last name) or by phone at 801-733-4455. Prov lists one Vermont test center, in Lyndonville; you can also test at any Prov center in the U.S. or remotely from home through Examroom.ai. You get your score as soon as you finish.
Schedule with Prov (opens in a new tab)Prov: Vermont Fire Safety Candidate Information Bulletin (PDF) (opens in a new tab)
Get licensed
Prov reports your result to the Division, which issues the license. Licenses run 3 years. The license fee is $115 for a journeyman and $150 for a master (26 V.S.A. 905), and renewal needs 15 hours of Board-approved NEC instruction in the preceding 36 months (26 V.S.A. 908).
Vermont Division of Fire Safety: electrical licensing (opens in a new tab)26 V.S.A. chapter 15 (electricians) (opens in a new tab)
Complete the Vermont energy goals module
Vermont requires a Vermont Energy Goals education module (no more than 2 hours by law; the Division says it takes about 20 minutes) before an initial license and each renewal. Send the completion certificate with your application.
Vermont Division of Fire Safety: trade licensing (opens in a new tab)
How to prepare
- Wiring and protection (34) and wiring methods and materials (21) are 55 of 105 questions; motors and controls (11) is much larger than on the journeyman exam.
- 26 V.S.A. 905(b) also has the master exam cover lightning rods, fire alarms and fire detection.
- The 2025 Vermont Electrical Safety Rules (effective Nov. 5, 2025) adopt the 2023 NEC with Vermont amendments, including changes to 210.8, 210.12, 230.70, 334 and 518. The local amendments section (5 questions) tests them, so tab the rules next to your NEC.
- You can take the exam up to 3 times on one approval (good for 3 years), with no waiting period and the same $80 fee each time; after that you reapply.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2023 National Electrical Code (NEC), NFPA 70Essential
Allowed in the exam room. Most of the electrician exams come from it.
Ugly's Electrical References, 2020
Allowed in the exam room. Quick tables and formulas.
Official reference list (as published by the testing agency)
- NFPA 70 National Electrical Code, 2023 (open book)
- Ugly's Electrical References, 2020 (open book)
- 2025 Vermont Electrical Safety Rules (open book)
- 26 V.S.A. chapter 15, Electricians (open book)
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Equipment for General Use | 10 | |
| General Electrical Knowledge | 12 | |
| Motors & Controls | 11 | |
| Special Conditions | 4 | |
| Special Equipment | 4 | |
| Special Occupancies | 4 | |
| Wiring & Protection | 34 | |
| Wiring Methods & Materials | 21 | |
| Local Amendments | 5 |
Exam day details
- Administered by Prov, Inc. for the Vermont Department of Public Safety, Division of Fire Safety.
- Fee: $80 to Prov per exam. Division application and license fees are separate.
- 105 questions in 5 hours; 70% to pass.
- Open book: only the references marked open book below are permitted in the exam room. Pen highlighting and underlining and permanent tabs are allowed; Post-it notes, loose formula sheets and marking your books during the exam are not.
- Once the Board approves you, it sends your details to Prov; schedule at provexam.com/scheduler or by phone at 801-733-4455. Prov lists one Vermont test center (Lyndonville), any Prov center in the U.S., or remote testing from home through Examroom.ai.
- You can take the exam up to 3 times on one approval, with no waiting period between attempts; after that you reapply to the Division. The approval is good for 3 years. Each attempt costs the $80 exam fee.
Frequently asked questions
What's on the Vermont master electrician exam?
105 questions: wiring and protection 34, wiring methods and materials 21, general electrical knowledge 12, motors and controls 11, equipment for general use 10, local amendments 5, and special conditions, special equipment and special occupancies 4 each.
How is it different from the journeyman exam?
It is longer (105 questions in 5 hours against 90 in 4) and weights motors and controls (11 against 3) and general electrical knowledge more heavily. The master exam allows 26 V.S.A. chapter 15 in the exam room; the journeyman exam lists it for study only.
Which NEC edition is on the exam?
The 2023 NEC with Vermont's amendments under the 2025 Vermont Electrical Safety Rules.
Free questions with answers
Show all 10 free questions and answers
A 120-volt branch circuit supplies a noncontinuous load of 16 amperes and a continuous load of 20 amperes. Before any ampacity adjustment or correction, what is the minimum conductor ampacity required by 210.19(A)(1)?
Answer: 41 amperes
Section 210.19(A)(1) requires the branch-circuit conductors to carry the noncontinuous load plus 125 percent of the continuous load: 16 + (1.25 x 20) = 16 + 25 = 41 A. Adding the loads without the 125 percent factor gives 36 A, and applying 125 percent to everything overstates the requirement at 45 A.
Reference: NFPA 70, National Electrical Code, 2023, 210.19(A)(1)
A branch circuit has a noncontinuous load of 14 amperes and a continuous load of 18 amperes. Using 210.20(A) and then the next standard overcurrent device rating allowed by 240.4(B) and 240.6(A), what rating of overcurrent device may be used?
Answer: 40 amperes
The minimum overcurrent device rating is 14 + (1.25 x 18) = 14 + 22.5 = 36.5 A (210.20(A)). Because 36.5 A is not a standard rating, 240.4(B) lets you go to the next higher standard size listed in 240.6(A), which is 40 A. A 35 A device is below the required value and a 45 A device is larger than necessary.
Reference: NFPA 70, National Electrical Code, 2023, 210.20(A); 240.4(B); 240.6(A)
Rigid metal conduit carrying 480-volt conductors is buried under the driveway of a one-family dwelling (used only for dwelling-related purposes). What is the minimum cover from Table 300.5(A)?
Answer: 18 inches
Table 300.5(A) gives 18 in. for rigid metal conduit under one- and two-family dwelling driveways and outdoor parking areas used only for dwelling-related purposes. Six inches is the cover for rigid metal conduit in most other locations, and 24 in. applies under streets, highways, alleys and non-residential driveways.
Reference: NFPA 70, National Electrical Code, 2023, Table 300.5(A)
A 15-horsepower, 230-volt, three-phase squirrel-cage motor has a Table 430.250 full-load current of 42 amperes. Using Table 430.52(C)(1) and the next-higher-standard-size provision of Exception No. 1, but not the exception for insufficient starting current, what is the largest standard inverse-time circuit breaker permitted for motor branch-circuit short-circuit and ground-fault protection?
Answer: 110 amperes
Table 430.52(C)(1) allows an inverse-time breaker up to 250 percent of the full-load current: 42 x 2.5 = 105 A. Because 105 A is not a standard rating, Exception No. 1 to 430.52(C)(1) permits the next higher standard rating in 240.6(A), which is 110 A. A 125 A breaker would require the starting-current exception, and 100 A is below the calculated value.
Reference: NFPA 70, National Electrical Code, 2023, 430.52(C)(1); Table 430.52(C)(1); 240.6(A)
A 15-kW, 240-volt, single-phase fixed electric space-heating load has no motors. Under 424.4, what is the minimum ampacity of the branch-circuit conductors?
Answer: 78.1 amperes
Full-load current is 15,000 W / 240 V = 62.5 A. Section 424.4(B) requires the branch-circuit conductors and overcurrent protection to be at least 125 percent of the total load: 62.5 x 1.25 = 78.1 A. Using the plain current ignores the 125 percent factor, and the 45.1 A choice results from using the three-phase formula by mistake.
Reference: NFPA 70, National Electrical Code, 2023, 424.4(B)
A 5,000-watt resistive heater is rated 240 volts. What is its resistance, using R = E squared / P?
Answer: 11.52 ohms
Resistance is voltage squared divided by power: 240 x 240 = 57,600; 57,600 / 5,000 = 11.52 ohms. Dividing 240 by the current without squaring, or dividing power by voltage (20.83 A), gives the wrong quantity. The current at 240 V is 5,000 / 240 = 20.83 A.
Reference: General electrical theory, Power formula, R = E x E / P
A single photovoltaic string has a module short-circuit current (Isc) of 11 amperes. Using 690.8(A) and 690.8(B), what is the minimum ampacity of the circuit conductors before adjustment and correction factors?
Answer: 17.2 amperes
Section 690.8(A) sets the maximum circuit current at 125 percent of Isc: 11 x 1.25 = 13.75 A. Section 690.8(B) then requires conductors to carry 125 percent of that value: 13.75 x 1.25 = 17.2 A. Using only the first factor gives 13.75 A, and 15.4 A is 140 percent of Isc, which is not a rule factor.
Reference: NFPA 70, National Electrical Code, 2023, 690.8(A) and 690.8(B)
In a Class I, Division 1 location, how close to an explosionproof enclosure that contains arcing or sparking devices must the conduit seal be located, in general, under 501.15(A)(1)?
Answer: Within 18 inches of the enclosure
Section 501.15(A)(1) requires a conduit seal within 450 mm (18 in.) of each conduit entry into an explosionproof enclosure that contains apparatus that may produce arcs, sparks or high temperatures. No union, coupling, box or fitting other than an explosionproof reducer or the seal itself may be placed between the seal and the enclosure.
Reference: NFPA 70, National Electrical Code, 2023, 501.15(A)(1)
Under the Vermont amendment to 230.70(A)(1), how far from the point of entrance of the service conductors may a service disconnecting means be located inside a building, and what label lets it also act as the emergency disconnect?
Answer: Not more than 10 feet of conductor length; labeled 'Emergency Service Disconnect'
The Vermont rules replace 230.70(A)(1) so the disconnect must be at a readily accessible location outside, or inside nearest the point of entrance, not to exceed 10 feet of conductor length from the point of entrance. A service disconnect can serve as the emergency disconnect if it is labeled 'Emergency Service Disconnect', and emergency disconnects without overcurrent protection are held to the 10-foot rule.
Reference: 2025 Vermont Electrical Safety Rules (Division of Fire Safety), 2025 Vermont Electrical Safety Rules, Section 5(a), amended NEC 230.70(A)(1)
Wiring from an emergency source to emergency loads under 700.10(B) must be kept in what relationship to other wiring?
Answer: Kept entirely independent of other wiring, unless the Code specifically allows otherwise
Section 700.10(B) requires emergency wiring to be kept entirely independent of all other wiring and equipment, with limited exceptions such as wiring from the normal source in transfer equipment enclosures and wiring supplied from two sources in exit or emergency luminaires. Independence prevents a fault in normal wiring from taking out emergency circuits.
Reference: NFPA 70, National Electrical Code, 2023, 700.10(B)
Sources
- Prov: Vermont Fire Safety Candidate Information Bulletin (2026.11.09, PDF) (opens in a new tab)
- Vermont Division of Fire Safety: electrical licensing (opens in a new tab)
- 26 V.S.A. chapter 15 (electricians) (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.