Requirements at a glance
| Who takes it | The qualifier for an H100 HVAC contractor license |
|---|---|
| Exams | Utah HVAC written (110 items, 120 min, 70%) + Utah Business & Law |
| Experience | Set by DOPL rule R156-55a for the H100 classification; check DOPL's contracting page |
| Code books | 2024 IMC and IFGC (+ Utah amendments), IRC, ACCA Manuals J, D, S |
| Also needed | Liability insurance, business registration, workers' comp or waiver, and EPA 608 for refrigerant work |
Qualifiers for the H100 HVAC Contractor license. You also need the Business & Law exam.
Official links
How to get licensed, step by step
Confirm your classification
H100 is DOPL's HVAC contractor classification (it replaced S350 in 2026; existing S350 holders have a transition period). It needs both the HVAC exam and the Business & Law exam.
DOPL: contracting exam information (opens in a new tab)DOPL: contracting laws and rules (opens in a new tab)
Register and schedule with Prov
Utah's licensing exams are given by Prov, Inc. Create an account, pick "HVAC", and choose a testing center (21 sites from Logan to St. George) or take the written exam from home through Examroom. Reschedule at least 3 business days ahead or you lose the fee.
Pass the HVAC and Business & Law exams
The HVAC exam has 110 items (100 scored, 10 unscored pilot questions) in 120 minutes, at 70%. Rules and Law is 25 of the 100 scored questions, so study the licensing law too.
Get EPA 608 certified
Anyone who handles refrigerant needs federal EPA 608 certification. That's a separate exam from an EPA-approved certifying program.
EPA list of approved 608 certifying programs (opens in a new tab)
Set up the business and apply
Insurance ($1M per incident / $2M total), business registration, EIN, and workers' comp or a waiver, then apply to DOPL.
DOPL: specialty contractor license (opens in a new tab)DOPL online application (opens in a new tab)
How to prepare
- Get the exact editions on the reference list. Answers are based on those editions, and Utah's statewide amendments change some sections.
- Tab your books before you study, not the night before: one permanent tab per chapter plus the tables you use most. Highlighting is allowed.
- Practice finding answers, not memorizing them. Open-book exams are a race against the clock: on a 4-hour, 100-question exam you have about 2.4 minutes per question.
- Rules and Law is a quarter of the exam. Read Utah Code 58-1 and R156-1 (licensing, renewal, unprofessional conduct).
- Know the air-side formulas (1.08 × CFM × ΔT, 4.5 × CFM × Δh, 400 CFM/ton) and the IMC sections on condensate, dryer exhaust and combustion air.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2024 IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2024 International Mechanical Code (IMC)Essential
Equipment access, condensate, exhaust (including dryer ducts), duct construction and refrigeration.
ICC store (opens in a new tab)Read free (opens in a new tab)
2024 International Fuel Gas Code (IFGC)
Combustion air, venting and gas pipe sizing.
ICC store (opens in a new tab)Read free (opens in a new tab)
International Residential Code (Prov lists 2024; Utah enforces 2021)
Mechanical chapters for houses. Check Prov's bulletin for which edition to bring.
ICC store (2021) (opens in a new tab)Read free (2021) (opens in a new tab)
ACCA Manual J (8th), Manual D (3rd), Manual S (2nd) and the ACCA duct slide rule
Load calculations, duct design and equipment selection.
Modern Refrigeration and Air Conditioning, 22nd Edition (Goodheart-Willcox)
Refrigeration cycle, troubleshooting, piping and controls.
Utah Code Title 15A, Chapter 3 (Utah's statewide code amendments)
Utah changes parts of the IPC, IFGC, IMC and NEC. Print the parts for your trade and tab them, or write the changes into your code book.
Utah Code 58-1 (Division of Professional Licensing Act)
License terms, renewal, discipline and unlawful conduct.
Official reference list (as published by the testing agency)
- International Mechanical Code, 2024 (+ Utah amendments)
- International Fuel Gas Code, 2024 (+ Utah amendments)
- International Residential Code (Prov lists 2024; Utah currently enforces the 2021 IRC)
- ACCA Manual J (8th ed.), Manual D (3rd ed.), Manual S (2nd ed.) and ACCA Duct Slide Rule
- Modern Refrigeration and Air Conditioning, 22nd Edition
- Utah Code 58-1 and Utah Admin. Code R156-1
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Rules and Law | 25 | |
| General Knowledge | 17 | |
| Systems and Sizing | 16 | |
| Plan Reading | 8 | |
| Maintenance | 7 | |
| Refrigeration Systems | 7 | |
| Piping | 7 | |
| Math and Calculations | 7 | |
| Electrical | 6 |
Exam day details
- Administered by Prov, Inc. for the Utah Division of Professional Licensing (DOPL).
- Fee: $85 written exam (Prov).
- The real exam has 110 items: 100 scored plus 10 unscored pilot questions you can't tell apart. Our simulation uses the 100 scored items.
- Rules and Law is a quarter of the exam, so don't skip the licensing law material.
Frequently asked questions
What code editions are on the Utah HVAC exam?
The 2024 IMC, IFGC and IRC with Utah amendments, plus ACCA Manuals J, D and S.
Do I also need the Business & Law exam for an H100 license?
Yes. DOPL requires both the Utah HVAC written exam and the Utah Business & Law exam.
Free questions with answers
Show all 10 free questions and answers
Under the Division of Professional Licensing Act, licenses issued under Title 58 are issued on what renewal cycle?
Answer: Two-year cycle
Utah Code 58-1-308(1)(a) says each license issued under Title 58 is issued on a two-year renewal cycle set by rule. Subsection (1)(b) lets the Division lengthen or shorten a single renewal period by up to one year, but only to keep or change the cycle. That adjustment is where the one-year and three-year choices come from. The standard cycle is still two years.
Reference: Utah Code Title 58, Chapter 1 (Division of Professional Licensing Act), 58-1-308(1)
Which term, as defined in the DOPL general rule, means disciplinary action that removes the right to use a license for a period of time or indefinitely, with the possibility of later reinstatement?
Answer: Suspension
R156-1-102(28) defines "suspend" as disciplinary action that removes the right to use a license for a period or indefinitely, with the possibility of later reinstatement. "Revoke" in R156-1-102(27) extinguishes the license entirely. "Cancel" in R156-1-102(3) is nondisciplinary, for example for a license issued in error. A public reprimand, R156-1-102(22), is a formal censure that doesn't remove the right to practice.
Reference: Utah Admin. Code R156-1 (General Rule of the Division of Professional Licensing), R156-1-102(28)
Under the IMC, what minimum level working space must be provided in front of the control side of an appliance for service?
Answer: 30 inches deep by 30 inches wide
IMC 2024 Section 306.1 requires a level working space at least 30 inches deep and 30 inches wide in front of the control side of an appliance. The same 30 x 30 service space shows up again in 306.3 (attics) and 306.4 (under floors). The 36-inch figure is the door and passageway width for rooms containing appliances, from 306.2. It is not the working space.
Reference: 2024 International Mechanical Code (as adopted in Utah), Section 306.1
A house has a 600 cfm kitchen range hood. All of its fuel-burning appliances inside the air barrier are direct-vent or use mechanical draft venting. Under Utah's statewide IMC amendments, is makeup air required for the hood?
Answer: No, because Utah's added Section 505.4.1 waives makeup air in this situation
IMC 2024 Section 505.4 normally requires makeup air, roughly equal to the exhaust rate, for hood systems that can exhaust more than 400 cfm. Utah Code 15A-3-401(2) adds Section 505.4.1. It says makeup air is not required in residential dwelling units when all fuel-burning appliances inside the unit's air barrier are direct-vent or use mechanical draft venting. The Utah amendment controls. Without those appliance conditions, the 400-cfm rule would still apply.
Reference: Utah Code Title 15A, Chapter 3 (statewide amendments), 15A-3-401(2) (adds IMC Section 505.4.1)
Using IMC Equation 4-9, what minimum continuous outdoor airflow is required for a 2,400-square-foot dwelling unit with 3 bedrooms?
Answer: 102 cfm
IMC 2024 Section 403.3.2.1, Equation 4-9, gives Q = 0.03 × A(floor) + 7.5 × (N(br) + 1). The floor term is 0.03 × 2,400 = 72 cfm. The bedroom term is 7.5 × (3 + 1) = 30 cfm, so Q = 72 + 30 = 102 cfm. Stopping after the floor term gives 72 cfm. Using 7.5 × 3 without the +1 gives 94.5 cfm. Using 0.01 cfm per square foot, the older ASHRAE 62.2-2010 area rate, gives 24 + 30 = 54 cfm.
Reference: 2024 International Mechanical Code (as adopted in Utah), Section 403.3.2.1, Equation 4-9
A 10-ton chilled water coil is designed for a 10°F water temperature rise. Using the water-side equation Btu/h = 500 × gpm × ΔT, what flow rate is required?
Answer: 24 gpm
First convert the load: 10 tons × 12,000 Btu/h per ton = 120,000 Btu/h. Then gpm = Btu/h ÷ (500 × ΔT) = 120,000 ÷ (500 × 10) = 24 gpm. The factor 500 is 8.33 lb/gal × 60 min/h × 1 Btu/lb·°F. Using a 20°F rise gives 12 gpm and a 5°F rise gives 48 gpm. Plugging in tons without converting to Btu/h, and misplacing a decimal, gives 2.4 gpm.
Reference: Modern Refrigeration and Air Conditioning, 22nd ed., Hydronic and chilled-water systems: Btu/h = 500 × gpm × ΔT
Refrigerants in IMC Table 1103.1 are classified by ASHRAE 34 safety group. What does the safety group "A2L" (for example, R-454B or R-32) indicate?
Answer: Lower toxicity and lower flammability, with a low burning velocity
IMC 2024 Section 1103.1 classifies refrigerants by the ASHRAE 34 safety groups in Table 1103.1. The letter gives toxicity: A is lower toxicity and B is higher toxicity. The number gives flammability: 1 means no flame propagation, 2 and 3 are increasingly flammable, and the "L" subclass (2L) means lower flammability with a low burning velocity. A1, like R-410A, means lower toxicity with no flame propagation. A2L refrigerants like R-454B and R-32 are mildly flammable, which is why the code adds labeling and installation rules for them.
Reference: 2024 International Mechanical Code (as adopted in Utah), Section 1103.1 and Table 1103.1
A field-erected refrigerant piping system is ready for its pressure test. Which test medium does the IMC allow?
Answer: Oxygen-free nitrogen
IMC 2024 Section 1110.3 lists the allowed field pressure test media: oxygen-free nitrogen, helium, argon, or premixed nonflammable oxygen-free nitrogen with a hydrogen or helium tracer. Section 1110.3.1 prohibits oxygen, air, refrigerants other than those listed, and combustible gases. Oxygen under pressure with oil residue can explode, and air brings in moisture.
Reference: 2024 International Mechanical Code (as adopted in Utah), Sections 1110.3 and 1110.3.1
A mechanical floor plan is drawn at 1/4" = 1'-0". A supply trunk measures 6-1/2 inches on the drawing. What is its actual length?
Answer: 26 feet
At 1/4" = 1'-0", each drawing inch equals 4 feet. So 6.5 in × 4 ft/in = 26 feet. A common mistake is to use the 1/8" scale factor (8 ft per inch) or to drop the half inch: 6 × 4 = 24 feet. Always check the scale in the title block, or on the individual detail, before measuring.
Reference: Modern Refrigeration and Air Conditioning, 22nd ed., Blueprint reading: drawing scales
Using the standard-air sensible heat equation Q = 1.08 × cfm × ΔT, what is the sensible heat delivered by 1,200 cfm with a 20°F temperature difference across the coil?
Answer: 25,920 Btu/h
Q = 1.08 × 1,200 × 20 = 25,920 Btu/h. Leaving out the 1.08 factor gives 24,000. Using the latent factor 0.68 by mistake gives 16,320. The 21,600 figure comes from using 0.90, a factor sometimes used for high altitude. At Utah elevations, the air density factor really is lower than the standard 1.08, so check which value the problem or your design procedure calls for.
Reference: Modern Refrigeration and Air Conditioning, 22nd ed., Psychrometrics: sensible heat (Q = 1.08 × cfm × ΔT)
Sources
- Prov: State of Utah HVAC Candidate Information Bulletin (2025-10-29) (opens in a new tab)
- Utah DOPL: Contracting exam information (opens in a new tab)
Questions last verified September 30, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.