Requirements at a glance
| Agency | South Carolina Department of Labor, Licensing and Regulation (LLR), Residential Builders Commission; exams by PSI |
|---|---|
| Experience | Residential builder: at least 1 year of experience under a licensed builder or equivalent approved by the Commission (S.C. Code 40-59-220). Licensed specialty contractors (HVAC, plumbing, electrical): 1 year of Commission-approved experience under the supervision of a licensee in the trade |
| Exams | Residential Plumbing: 65 questions, 3 hours, 68%, plus Business Management and Law for Residential Builders |
| Books allowed | IPC 2021 or 2024 (SC), the SC IRC and 29 CFR 1926 |
| Fees | PSI exam fees ($78 for one portion, $98 for both with the builder exam), plus the Commission's application and license fees and a bond |
Applicants for a Residential Builders Commission residential plumbing specialty contractor license.
Official links
How to get licensed, step by step
Apply to the Commission
Apply to the Residential Builders Commission first. Eligibility is valid for 1 year.
SC Residential Builders Commission (LLR) (opens in a new tab)S.C. Code Title 40 Chapter 59 (residential builders) (opens in a new tab)
Schedule Business and Law and the residential plumbing exam with PSI
You must pass both portions within 12 months and get 3 attempts in that period. After three failures you wait twelve months.
Schedule with PSI (residential builders) (opens in a new tab)
Get licensed
After you pass both portions, send the Commission your results, the license fee and your bond. The residential builder bond is $15,000 (S.C. Code 40-59-220).
SC Residential Builders Commission (LLR) (opens in a new tab)
How to prepare
- Code editions are changing. From November 1, 2026 PSI accepts the 2021 or the 2024 South Carolina codes (ICC codes with state modifications) and the 2023 or the 2020 NEC. After July 1, 2027 only the 2024 codes and the 2023 NEC. Bring one edition you know well and expect questions that read the same in both.
- Tab your books before exam day: highlighting, underlining and permanent tabs are allowed, but sticky notes and writing during the exam are not.
- Drain, waste and vent and sewers (17) and general plumbing knowledge and regulations (15) are half the exam: tab the IPC venting, trap, sizing and testing sections.
- Isometric analysis is 9 questions: practice reading fixture counts, pipe lengths and fittings from a drawing.
- Piping, valves and controls (6), specialty applications such as water heaters and backflow (6), fixtures (4), water supply (4) and safety (4) fill the rest.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the SC IPC and the SC IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Plumbing Code (IPC), 2021 or 2024 edition with South Carolina modificationsEssential
On PSI's list. Most of the plumber exam.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
International Residential Code (IRC), 2021 or 2024 edition with South Carolina modificationsEssential
On PSI's list. The code book for the residential builder exam, including its electrical, mechanical and plumbing chapters.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
29 CFR Part 1926 (OSHA construction regulations)
On PSI's list for the building, electrical, plumbing and HVAC exams. Safety questions.
Official reference list (as published by the testing agency)
- International Plumbing Code (IPC), 2021 or 2024 edition (or the South Carolina Plumbing Code)
- International Residential Code (IRC), 2021 or 2024 edition (South Carolina IRC)
- Code of Federal Regulations, 29 CFR Part 1926 (on PSI's list)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Plumbing Knowledge and Regulations | 15 | |
| Piping, Valves, and Controls | 6 | |
| Fixtures and Equipment | 4 | |
| Water Supply | 4 | |
| Drain, Waste and Vent and Sewers | 17 | |
| Isometric Analysis | 9 | |
| Safety | 4 | |
| Specialty Applications | 6 |
Exam day details
- Administered by PSI Services for the South Carolina Department of Labor, Licensing and Regulation (Residential Builders Commission).
- Fee: $78 to PSI for the trade portion alone, or $94 for both portions (business and law plus Residential Plumbing). Board application and license fees are separate.
- 65 scored questions plus 1 to 10 unscored experimental items (they count against your time) in 180 minutes; 44 of 65 correct (67.7%); PSI notes the passing score may change.
- Code editions: from November 1, 2026 PSI accepts the 2021 or 2024 South Carolina codes (NEC 2023 or 2020); after July 1, 2027 only the 2024 codes and the 2023 NEC. Our questions are written to be correct under both.
- Open book: bring the references on PSI's list. You may highlight, underline and add permanent tabs; sticky notes and removable tabs are not allowed.
- Apply to the Residential Builders Commission first. Eligibility is valid for 1 year and you get 3 attempts within 12 months; you must pass Business Management and Law and the trade portion within that 12 months.
- After three failures you wait twelve months from the last attempt before testing again.
Frequently asked questions
What's on the South Carolina residential plumbing exam?
65 scored questions, led by drain, waste and vent and sewers 17, general plumbing knowledge and regulations 15, isometric analysis 9, piping, valves and controls 6, specialty applications 6 and 3 smaller topics.
Does it cover only homes?
Yes. It covers plumbing work on residential structures of 16 units or less and no more than 3 stories.
What is the passing score?
44 of 65 (67.7%). PSI notes the passing score may change as exam performance is evaluated.
Free questions with answers
Show all 10 free questions and answers
A new building sewer is being tested before backfill. A test plug is set at the connection to the public sewer and the sewer is filled with water. What head of water must be applied, and for how long must the pressure hold without dropping?
Answer: At least a 10-foot head of water, held for at least 15 minutes
Section P2503.4 requires the building sewer to be filled with water and pressurized to not less than a 10-foot head, with no drop in test pressure for at least 15 minutes, and the sewer must be watertight at every point. The 10-foot head is about 4.3 psi. The other head and time combinations are not what the section states.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, P2503.4
A plumber finishes the copper water supply piping in a house and wants to test it with compressed air instead of water. What is the minimum air test pressure and hold time for a piping system other than plastic?
Answer: 50 psi held for at least 15 minutes
Section P2503.7 requires the water supply system to be proved tight at not less than the working pressure of the system, or for piping other than plastic, by an air test of not less than 50 psi. Either way the pressure is held for at least 15 minutes.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, P2503.7
Faucets and valves in a new kitchen will supply water for drinking and cooking. What lead content limit applies to those pipes, fittings, valves and fixture fittings?
Answer: A weighted average of 0.25 percent lead or less, and they must comply with NSF 372
Section P2906.2 limits lead in water supply pipe and fittings to 8 percent, but P2906.2.1 is stricter for components that supply drinking or cooking water: they must comply with NSF 372 and have a weighted average lead content of 0.25 percent or less.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, P2906.2 and P2906.2.1
A tub/shower combination valve is installed in a new house. What must the valve be equipped with to limit scalding?
Answer: A high-limit stop adjusted so the water does not exceed 120°F
Section P2708.4 requires individual shower and tub/shower valves to be balanced-pressure, thermostatic, or combination balanced-pressure/thermostatic valves with a means to limit the maximum setting to 120°F, field-adjusted per the manufacturer's instructions. In-line thermostatic valves may not be used to meet this requirement.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, P2708.4
A pressure-reducing valve is installed at the service, and the water heater is a closed system, so that thermal expansion raises the downstream pressure above the valve setting. What does the code require?
Answer: A device for controlling the thermal expansion pressure, such as an expansion tank
Sections P2903.4 and P2903.4.1 require a device for controlling pressure where thermal expansion pushes the pressure downstream of a pressure-reducing valve above its setting (for service sizes up to 2 inches). P2903.4.2 requires the same where a backflow preventer or check valve with storage water heating causes pressure to rise. A shutoff on a relief discharge line is prohibited by P2804.6.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, P2903.4, P2903.4.1 and P2903.4.2
A 20-foot horizontal run of 3-inch drain pipe will be installed at the minimum slope allowed by the code. How much total fall must the run have?
Answer: 2 1/2 inches
Section P3005.3 requires 1/4 inch per foot for pipe 2 1/2 inches and smaller, and 1/8 inch per foot for pipe 3 inches or larger. For 3-inch pipe, 20 ft x 1/8 in = 2.5 inches of fall. Using 1/4 inch per foot gives 5 inches, 1/16 inch per foot gives 1 1/4 inches, and 3/16 inch per foot gives 3 3/4 inches.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, P3005.3
A house has two full baths (counted as a 2-bath group), a kitchen group and a laundry group. What total d.f.u. load is used to size the building drain?
Answer: 13 d.f.u.
Table P3004.1 assigns 8 d.f.u. to a 2-bath group, 2 d.f.u. to a kitchen group (dishwasher and sink) and 3 d.f.u. to a laundry group (washer standpipe and laundry tub). 8 + 2 + 3 = 13 d.f.u. Adding two 5-unit bath groups (10) instead of the 8-unit multiple-bath value gives 15, omitting the laundry group gives 10, and adding the individual fixtures gives a higher total.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, Table P3004.1
An isometric shows a kitchen sink with a 1 1/2-inch trap. From the trap weir to the vent fitting the fixture drain runs 14 inches of vertical pipe, 3 feet 8 inches of horizontal pipe at 1/4 inch per foot, then a 45-degree bend and 1 foot 4 inches more pipe, all measured along the centerline. Does the arrangement comply with Table P3105.1?
Answer: No, the 74-inch developed length exceeds the 6-foot (72-inch) maximum for a 1 1/2-inch trap
Developed length is measured along the centerline of the pipe and fittings from the trap weir to the vent fitting: 14 + 44 + 16 = 74 inches, or 6 feet 2 inches. Table P3105.1 allows 6 feet for a 1 1/2-inch trap at 1/4 inch per foot (5 feet for 1 1/4 inches, 8 feet for 2 inches, 12 feet for 3 inches at 1/8 inch per foot, 16 feet for 4 inches). The layout fails by 2 inches, so the vent must move closer or the trap arm must be shortened.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, P3105.1 and Table P3105.1
A plumbing crew is digging a sewer trench. At what depth must an adequate protective system (sloping, shoring or a shield) generally be used, unless the excavation is in stable rock?
Answer: 5 feet or deeper
29 CFR 1926.652(a)(1) requires each employee in an excavation to be protected from cave-ins by an adequate protective system, except in stable rock or where the excavation is less than 5 feet deep and a competent person finds no indication of a potential cave-in. The 4-foot depth is the trigger for access/egress and atmospheric testing, not for protective systems.
Reference: 29 CFR Part 1926, 1926.652(a)(1)
A lawn irrigation system will be fed from a house water supply using an atmospheric vacuum breaker. Which installation rule applies?
Answer: No valves may be installed downstream of the atmospheric vacuum breaker
Section P2902.5.3 allows lawn irrigation systems to be protected by an atmospheric vacuum breaker, a pressure vacuum breaker assembly or a reduced pressure principle assembly, and says valves shall not be installed downstream of an atmospheric vacuum breaker (continuous pressure would defeat it). Where chemicals are introduced, a reduced pressure principle assembly is required.
Reference: South Carolina Residential Code (2021 IRC); same text in 2024 IRC unless noted, P2902.5.3
Sources
- PSI: South Carolina Residential Builders Commission Candidate Information Bulletin (updated 11/1/2026) (opens in a new tab)
- South Carolina Residential Builders Commission (LLR) (opens in a new tab)
- South Carolina Code of Laws Title 40 Chapter 59 (residential builders) (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.