South Carolina licensing exam

South Carolina Residential Electrical Exam: Practice Test & Licensing Guide

PSI's open-book trade exam for the South Carolina residential electrical specialty contractor: 60 questions on services, branch circuits, overcurrent protection, grounding, wiring methods, lighting and pool, garage and generator wiring. 44 correct to pass.

Questions
60
Time limit
3 hours
Passing score
73%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Electrical Knowledge

A 240-volt, 4,500-watt electric water heater element is being replaced. Using R = E squared / P, what is the resistance of the element when it is hot and operating at rated values?

Requirements at a glance

AgencySouth Carolina Department of Labor, Licensing and Regulation (LLR), Residential Builders Commission; exams by PSI
ExperienceResidential builder: at least 1 year of experience under a licensed builder or equivalent approved by the Commission (S.C. Code 40-59-220). Licensed specialty contractors (HVAC, plumbing, electrical): 1 year of Commission-approved experience under the supervision of a licensee in the trade
ExamsResidential Electrical: 60 questions, 3 hours, 73%, plus Business Management and Law for Residential Builders
Books allowedNEC 2023 or 2020 with SC modifications, the SC IRC, Ugly's Electrical References and the Key Word Index
FeesPSI exam fees ($78 for one portion, $98 for both with the builder exam), plus the Commission's application and license fees and a bond

Applicants for a Residential Builders Commission residential electrical specialty contractor license. (PSI also offers the NASCLA residential electrical exam as an alternative trade exam; this is the South Carolina exam.)

How to get licensed, step by step

  1. Apply to the Commission

    Apply to the Residential Builders Commission first. Eligibility is valid for 1 year.

    SC Residential Builders Commission (LLR) (opens in a new tab)S.C. Code Title 40 Chapter 59 (residential builders) (opens in a new tab)

  2. Schedule Business and Law and the residential electrical exam with PSI

    You must pass both portions within 12 months and get 3 attempts in that period. After three failures you wait twelve months.

    Schedule with PSI (residential builders) (opens in a new tab)

  3. Get licensed

    After you pass both portions, send the Commission your results, the license fee and your bond. The residential builder bond is $15,000 (S.C. Code 40-59-220).

    SC Residential Builders Commission (LLR) (opens in a new tab)

How to prepare

  • Code editions are changing. From November 1, 2026 PSI accepts the 2021 or the 2024 South Carolina codes (ICC codes with state modifications) and the 2023 or the 2020 NEC. After July 1, 2027 only the 2024 codes and the 2023 NEC. Bring one edition you know well and expect questions that read the same in both.
  • Tab your books before exam day: highlighting, underlining and permanent tabs are allowed, but sticky notes and writing during the exam are not.
  • Services, feeders and branch circuits (15) and general electrical knowledge (13) are almost half the exam: practice Ohm's law, voltage drop and load calculations.
  • South Carolina modifies NEC 210.8(A), 210.8(F) and 210.12(B); read the state changes before the exam.
  • Overcurrent protection (5), grounding and bonding (6), conductors and cables (5), raceways and boxes (4), lighting (4), pool, garage and generator wiring (4) and safety (4) round it out.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC and the SC IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • National Electrical Code (NEC), 2023 or 2020 edition with South Carolina modifications (or the NEC Handbook)
  • International Residential Code (IRC), 2021 or 2024 edition (South Carolina IRC)
  • Key Word Index (Tom Henry); Ugly's Electrical References, 2017
  • Code of Federal Regulations, 29 CFR Part 1926 (on PSI's list)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Electrical Knowledge13
Services, Feeders, and Branch Circuits15
Overcurrent Protection5
Grounding and Bonding6
Conductors and Cables5
Raceways and Boxes4
Lighting4
Specialty (pool/spa, garages, generators, wheelchair lifts)4
Safety4

Exam day details

  • Administered by PSI Services for the South Carolina Department of Labor, Licensing and Regulation (Residential Builders Commission).
  • Fee: $75 to PSI for the trade portion alone, or $94 for both portions (business and law plus Residential Electrical). Board application and license fees are separate.
  • 60 scored questions plus 1 to 10 unscored experimental items (they count against your time) in 180 minutes; 44 of 60 correct (73.3%); PSI notes the passing score may change.
  • Code editions: from November 1, 2026 PSI accepts the 2021 or 2024 South Carolina codes (NEC 2023 or 2020); after July 1, 2027 only the 2024 codes and the 2023 NEC. Our questions are written to be correct under both.
  • Open book: bring the references on PSI's list. You may highlight, underline and add permanent tabs; sticky notes and removable tabs are not allowed.
  • Apply to the Residential Builders Commission first. Eligibility is valid for 1 year and you get 3 attempts within 12 months; you must pass Business Management and Law and the trade portion within that 12 months.
  • After three failures you wait twelve months from the last attempt before testing again.

Frequently asked questions

What's on the South Carolina residential electrical exam?

60 scored questions, led by services, feeders and branch circuits 15, general electrical knowledge 13, grounding and bonding 6, overcurrent protection 5, conductors and cables 5 and 4 smaller topics.

Does it cover only homes?

Yes. It covers electrical work on residential structures of 16 units or less and no more than 3 stories.

What is the passing score?

44 of 60 (73.3%). PSI notes the passing score may change as exam performance is evaluated.

Free questions with answers

Show all 10 free questions and answers
  1. A 240-volt, 4,500-watt electric water heater element is being replaced. Using R = E squared / P, what is the resistance of the element when it is hot and operating at rated values?

    Answer: 12.8 ohms

    R = E x E / P = 240 x 240 / 4,500 = 57,600 / 4,500 = 12.8 ohms. The current is 4,500 / 240 = 18.75 A, a different quantity. Using 120 V instead of 240 V gives 14,400 / 4,500 = 3.2 ohms, because the voltage is squared.

    Reference: General electrical theory, Ohm's law and power formulas (R = E^2 / P)

  2. In a living room, a short wall segment 22 in. wide sits between two doorways. Is a receptacle required on that segment?

    Answer: No, because the segment is narrower than 2 ft and does not count as wall space

    210.52(A)(2) defines a wall space as 2 ft (24 in.) or more in width, unbroken along the floor line by doorways and similar openings. A 22-in. segment is under 2 ft, so it is not wall space and needs no receptacle. The 12-in. and 18-in. figures belong to other rules, such as countertop width and floor receptacle location.

    Reference: NEC 2020/2023 (rule identical in both), 210.52(A)(2)

  3. Receptacle outlets that serve a kitchen countertop must be located no higher than how far above the countertop?

    Answer: 20 inches

    210.52(C)(3) of NEC 2023 requires countertop receptacle outlets to be on or above, but not more than 20 in. above, the countertop or work surface, or in the countertop using a listed assembly. NEC 2020 has the same 20-in. limit in the receptacle-outlet-location subdivision of 210.52(C). Anything mounted higher does not satisfy the requirement.

    Reference: NEC 2023 (same 20-in. limit in NEC 2020; subdivision numbered differently), 210.52(C)(3)

  4. A circuit supplying only a fixed 240-volt heater (no receptacles) uses conductors with an allowable ampacity of 55 amperes. What is the largest standard-size overcurrent device permitted under the next-higher-rating rule?

    Answer: 60 amperes

    240.4(B) allows the next higher standard rating above the conductor ampacity if the circuit does not supply multiple receptacles for cord-and-plug portable loads, the ampacity does not match a standard rating, and the next size does not exceed 800 A. 55 A falls between the standard 50 A and 60 A ratings in Table 240.6(A), so 60 A is the largest permitted.

    Reference: NEC 2020/2023 (rule identical in both), 240.4(B); Table 240.6(A)

  5. In a one-family house, a 100-ampere subpanel is installed in the basement and fed from the main service panel in the same building. How must the neutral and equipment grounding conductors be connected in the subpanel?

    Answer: The neutral bar is isolated from the enclosure and the equipment grounding bar is bonded to the enclosure

    The grounded conductor is bonded to the enclosure only at the service (the main bonding jumper). On the load side, 250.24(B) (250.24(A)(5) in 2020) prohibits connecting the grounded conductor to equipment grounding conductors or enclosures or reconnecting it to ground. A subpanel in the same building therefore keeps its neutral isolated and bonds the equipment grounding bar to the enclosure, so normal neutral current never travels on metal parts.

    Reference: NEC 2023 (2020: 250.24(A)(5), same rule), 250.24(B)

  6. Seven current-carrying 10 AWG copper THHN conductors are installed in one conduit. The temperature is 30 degrees C. Starting from the 90 degree C ampacity of 40 amperes, what is the adjusted ampacity of each conductor?

    Answer: 28 amperes

    Table 310.15(C)(1) gives 70 percent for 7 to 9 current-carrying conductors: 40 x 0.70 = 28 A. The 80 percent factor is for 4 to 6 conductors and 50 percent for 10 to 20. The adjustment factors apply to the ampacity at the conductor temperature rating (here 90 degrees C), and the result must still not exceed the termination limit in 110.14(C).

    Reference: NEC 2020/2023 (same table number and factors in both), Table 310.15(C)(1)

  7. At each outlet box, what minimum length of free conductor must be left, measured from where the conductor emerges from the cable sheath or raceway?

    Answer: 6 inches

    300.14 requires at least 6 in. of free conductor, measured from the point in the box where it emerges from its raceway or cable sheath, at each outlet, junction and switch point for splices or the connection of devices. Where the box opening is less than 8 in. in any dimension, each conductor must also extend at least 3 in. outside the opening.

    Reference: NEC 2020/2023 (rule identical in both), 300.14

  8. A switch loop is being installed for a ceiling light in a bedroom, using the luminaire outlet box as the supply point. What must be provided at the switch location?

    Answer: A grounded (neutral) conductor in the switch box, unless an exception applies

    404.2(C) requires the grounded circuit conductor of the controlled lighting circuit to be installed at the switch location where the switch controls lighting loads on a grounded general-purpose branch circuit serving bathrooms, hallways, stairways and habitable rooms, so electronic switches can be powered later. Exceptions include raceway wiring that is large enough to add a conductor and certain other conditions, so the rule applies to NM wiring in a bedroom.

    Reference: NEC 2023 (2020: 404.2(C), same requirement), 404.2(C)

  9. A service drop made of insulated conductors cabled on a solidly grounded bare messenger (not over 750 volts to ground) passes near a residential in-ground pool. What is the minimum clearance in any direction to the maximum water level?

    Answer: 22 ft 6 in.

    Table 680.9(A), row A, lists 6.9 m (22 1/2 ft) for insulated cables 0 to 750 volts to ground supported on and cabled together with a solidly grounded bare messenger or neutral. The 25 ft figure is for all other conductors rated 0 to 15 kV, and 14 1/2 ft is the clearance for observation stands, towers or diving platforms.

    Reference: NEC 2023 numbering (2020 requires the same distance), Table 680.9(A), row A

  10. A 12-ft non-self-supporting ladder (working length 12 ft) will lean against a wall. About how far from the wall should its feet be placed?

    Answer: 3 feet

    1926.1053(b)(5)(i) says non-self-supporting ladders must be used at an angle such that the horizontal distance from the top support to the foot is approximately one-quarter of the working length. 12 ft / 4 = 3 ft. A 4-ft base would be one third of the length and a 6-ft base half of it.

    Reference: 29 CFR Part 1926 (eCFR), 1926.1053(b)(5)(i)

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.