Requirements at a glance
| Agency | Rhode Island Department of Labor and Training (Division of Professional Regulation); the DLT gives the exam itself |
|---|---|
| Exam | Question count, time and open-book rule not published by the DLT; written; 70 or greater to pass (DLT application; rule 260-RICR-30-15-7) |
| Experience | Certificate A electrical contractor: 6 years of experience plus a Rhode Island journeyperson license held for 2 years (DLT application) |
| Books | The rule disqualifies reference to notes or books unless the Board permits; ask the DLT what you may bring |
| Fees | $75 exam application to the DLT; $240 biennial contractor license |
Electricians applying to the Board of Examiners of Electricians to operate as an electrical contractor. The DLT application asks for 6 years of experience and a Rhode Island journeyperson license held for 2 years.
Official links
How to get licensed, step by step
Meet the experience requirement
Gain 6 years of experience and hold a Rhode Island journeyperson license for 2 years, per the DLT application.
Rhode Island DLT: Professional Regulation (opens in a new tab)RIGL chapter 5-6 (electricians) (opens in a new tab)
Apply to the DLT
File the exam application with the Division of Professional Regulation (Cranston) with the $75 non-refundable fee by check or money order (RIGL 5-6-17). Use the DLT's current form.
Rhode Island DLT: trade license applications and study materials (opens in a new tab)
Wait for your exam notice
The DLT approves applicants, then mails the date and place of the next sitting. Applications must reach the Division 15 working days before the exam date. Phone 401-462-8580 or 401-462-8526 to confirm the format, what you may bring and the next date.
Rhode Island DLT: Professional Regulation (opens in a new tab)
Get licensed
You need an average of at least 70% (rule 260-RICR-30-15-7). The license fee is $72 for a journeyperson or $240 for a contractor, biennial, and renewal needs 15 hours of continuing education (RIGL 5-6-20.1).
Rhode Island DLT: Professional Regulation (opens in a new tab)RIGL chapter 5-6 (electricians) (opens in a new tab)
How to prepare
- Expect more load calculation, motor and law and rules material than at the journeyman level; the DLT publishes no weights.
- Read RIGL chapter 5-6 for the contractor's obligations.
- Rhode Island adopted the 2023 NEC with amendments (210.25, 230.24(A) Exception 5 deleted, 230.82 supply-side equipment) effective 12/01/2025. The exam rule says questions follow the edition in force at the time, and the DLT study list names the current NEC (latest state-approved edition) plus general trade knowledge; we couldn't confirm which edition the exam uses today.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
2023 National Electrical Code (NEC), NFPA 70, with Rhode Island amendments (RISBC-5)Essential
The state-adopted edition from 12/01/2025. Confirm with the DLT which edition your exam uses.
Official reference list (as published by the testing agency)
- NFPA 70 National Electrical Code with the Rhode Island amendments (RISBC-5, 510-RICR-00-00-5)
- Rhode Island General Laws chapter 5-6 (electricians)
- 260-RICR-30-15-7: Board of Examiners of Electricians rules
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Wiring and Protection | 12 | |
| Grounding and Bonding | 7 | |
| Wiring Methods and Materials | 10 | |
| Services, Feeders and Load Calculations | 10 | |
| Motors, Controls and Equipment | 8 | |
| Special Occupancies and Conditions | 5 | |
| Rhode Island Law and Rules | 8 |
Exam day details
- Administered by Rhode Island Department of Labor and Training (Division of Professional Regulation).
- Fee: $75 application fee to the DLT (RIGL 5-6-17, 5-20-17), non-refundable, by check or money order. Two-year license fees are separate: $240 for a master or contractor, $72 for a journeyperson.
- Rule 260-RICR-30-15-7 says exams are written, based on the NEC edition the state has adopted at the time of the exam, and may include practical demonstrations.
- You need an average of at least 70% to be licensed, and at least 60% to review your exam with the Board.
- The rule disqualifies anyone found referring to notes or books during the exam unless the Board gives permission. Ask the Division what you may bring.
- The Department of Labor and Training writes and gives this exam on paper at scheduled sittings and mails each approved applicant the date and place. It doesn't publish the number of questions, the time limit or the topic weights.
- Applications must reach the Division 15 working days before the exam date.
- A new exam fee applies each time you retake.
Note: The DLT writes and gives this exam itself and publishes no time limit, topic weights or open-book rule, and for electricians no question count. Our timer and topic split (and the electrician length) are practice estimates built from the statutes and the adopted codes. Confirm the format with the DLT (401-462-8580) when you are approved. Rhode Island adopted the 2023 NEC (RISBC-5, effective 12/01/2025) with state amendments, and the electrician exam rule says questions follow the NEC edition adopted at the time of the exam. The DLT study-materials page lists the current NEC (latest state-approved edition) plus general trade knowledge. We could not confirm which edition the DLT exam uses today, so check with the DLT.
Frequently asked questions
Is Certificate A the master electrician license?
Yes. Rhode Island's Certificate A is the electrical contractor license, which is the master level; Certificate B is the journeyman. The contractor license fee is $240 and runs two years, against $72 for a journeyman.
What's on the exam?
The DLT publishes no topic list or question count. Expect the NEC (wiring, grounding, services and load calculations, motors) and Rhode Island electrical law; our topic split is an estimate.
Is continuing education required?
Yes: 15 hours per renewal under RIGL 5-6-20.1.
Free questions with answers
Show all 10 free questions and answers
An applicant scores an average of 64 percent on the written electrician examination. Under the board's rule, what is the result?
Answer: The applicant fails but may review the examination with the board members
Rule 7.5(C) requires 70% to be licensed and at least 60% to review the examination with the board. 64% is below passing but above the review threshold.
Reference: 260-RICR-30-15-7, 260-RICR-30-15-7, s.7.5(C)
Under the Rhode Island amendment to NEC 210.25(A), what may a branch circuit in a dwelling unit supply?
Answer: Only loads within that dwelling unit or loads associated only with that dwelling unit
The Rhode Island text that replaces 210.25 requires dwelling-unit branch circuits to supply only loads within, or associated only with, that dwelling unit. Common-area loads are handled by 210.25(B) and may not come from a tenant's panel.
Reference: NFPA 70, National Electrical Code, 2023, with RISBC-5 amendments (510-RICR-00-00-5), 210.25(A) as amended by RISBC-5
Which Rhode Island exception to 210.25(B) lets an existing three-family dwelling supply its common-area smoke and carbon monoxide alarms from a dwelling unit panel, and what must accompany it?
Answer: The alarm circuits in the common areas may come from a unit's equipment if written documentation shows no interruption of service to those devices
The Rhode Island exception under 210.25(B)(1) covers smoke/CO alarms required for three-family dwellings and permits the supply from equipment serving an individual unit, if written documentation is supplied that there will be no interruption in service to the common-area devices. It is written for existing three-family dwellings.
Reference: NFPA 70, National Electrical Code, 2023, with RISBC-5 amendments (510-RICR-00-00-5), 210.25(B)(1) as amended by RISBC-5
A 120/240-volt service uses 4/0 AWG copper service-entrance conductors. Using Table 250.66, what is the minimum size copper grounding electrode conductor to the electrode system?
Answer: 2 AWG
In Table 250.66, 4/0 AWG copper is over 3/0 and not over 350 kcmil, so the copper grounding electrode conductor is 2 AWG. The 4 AWG entry belongs to 2/0 and 3/0 conductors, and 6 AWG is only for 1 AWG and 1/0 conductors.
Reference: NFPA 70, National Electrical Code, 2023, Table 250.66
What is the minimum rating of the service disconnecting means for a one-family dwelling under 230.79(C)?
Answer: 100 amperes, 3-wire
Section 230.79(C) says that for a one-family dwelling the service disconnecting means shall be rated not less than 100 amperes, 3-wire. The 60 ampere minimum in 230.79(D) is for all other installations.
Reference: NFPA 70, National Electrical Code, 2023, 230.79(C)
What is the maximum number of service disconnecting means permitted for one service under 230.71(B)?
Answer: Six
Section 230.71(B) permits two to six service disconnecting means for each service, made up of separate enclosures each with a main disconnect, panelboards each with a main disconnect, or switchboard sections or switchgear arranged as that section describes. Six is the maximum.
Reference: NFPA 70, National Electrical Code, 2023, 230.71(B)
What are the maximum intervals for securing Type NM cable and the maximum distance from a device box to the first support under 334.30?
Answer: Every 4 1/2 feet, and within 12 inches of each box
Section 334.30 requires NM cable to be supported at intervals not exceeding 4 1/2 ft and within 12 in. of every cable entry into an outlet box, junction box, cabinet or fitting. The 3 ft distance is the EMT and rigid conduit rule, and the 6 ft interval is for Type MC.
Reference: NFPA 70, National Electrical Code, 2023, 334.30
Type MC cable with three 12 AWG conductors is run along joists to a junction box. What are the securing requirements under 330.30(B)?
Answer: Secured at intervals not exceeding 6 feet and within 12 inches of the box
Section 330.30(B) says MC cable is secured at intervals not exceeding 1.8 m (6 ft), and cables with four or fewer conductors no larger than 10 AWG are secured within 300 mm (12 in.) of every box, cabinet, fitting or other termination.
Reference: NFPA 70, National Electrical Code, 2023, 330.30(B)
A feeder supplies three three-phase 230-volt motors of 10 hp (28 A), 5 hp (15.2 A) and 3 hp (9.6 A), using Table 430.250 values, and no other load. What is the minimum feeder conductor ampacity under 430.24?
Answer: 59.8 amperes
Section 430.24 requires 125 percent of the largest motor plus 100 percent of the others: (1.25 x 28) + 15.2 + 9.6 = 35.0 + 24.8 = 59.8 A. The 125 percent factor applies to the highest-rated motor only.
Reference: NFPA 70, National Electrical Code, 2023, 430.24
Where a permanently installed pool is built, what is the required location of the receptacle on a general-purpose branch circuit under 680.22(A)(1)?
Answer: At least 6 feet and not more than 20 feet from the inside wall of the pool
Section 680.22(A)(1) requires at least one 125-volt, 15- or 20-ampere receptacle on a general-purpose branch circuit not less than 1.83 m (6 ft) and not more than 6.0 m (20 ft) from the inside wall of the pool, and not more than 6 ft 6 in. above the floor or grade serving the pool.
Reference: NFPA 70, National Electrical Code, 2023, 680.22(A)(1)
Sources
- Rhode Island Department of Labor and Training: Professional Regulation (opens in a new tab)
- Rhode Island DLT: trade license applications and study materials (opens in a new tab)
- Rhode Island General Laws chapter 5-6 (electricians) (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.