Rhode Island licensing exam

Rhode Island Journeyman Electrician Exam: Practice Test & Licensing Guide

The Department of Labor and Training's written exam for a Rhode Island journeyman electrician (Certificate B). The DLT publishes no question count, time or topic weights, so this practice bank follows the NEC and Rhode Island electrical law. An average of 70% is needed to be licensed.

Questions
Not published by Rhode Island
Time limit
Not published by Rhode Island
Passing score
70%
Books
Not published by Rhode Island
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Wiring and Protection

A branch circuit supplies a continuous load of 28 amperes and no other load. The overcurrent device is not listed for operation at 100 percent of its rating. What is the minimum standard rating of the overcurrent device?

Requirements at a glance

AgencyRhode Island Department of Labor and Training (Division of Professional Regulation); the DLT gives the exam itself
ExamQuestion count, time and open-book rule not published by the DLT; written; 70 or greater to pass (DLT application; rule 260-RICR-30-15-7)
Experience4 years of experience plus 576 hours of related instruction (DLT application); the rule describes an apprenticeship of 8,000 hours over at least 4 years (Certificate B)
BooksThe rule disqualifies reference to notes or books unless the Board permits; ask the DLT what you may bring
Fees$75 exam application to the DLT; $72 biennial journeyperson license

Electricians applying to the Board of Examiners of Electricians for a journeyman license with 4 years of experience and 576 hours of related instruction, per the DLT application.

How to get licensed, step by step

  1. Meet the experience requirement

    Gain 4 years of experience and 576 hours of related instruction, per the DLT application.

    Rhode Island DLT: Professional Regulation (opens in a new tab)RIGL chapter 5-6 (electricians) (opens in a new tab)

  2. Apply to the DLT

    File the exam application with the Division of Professional Regulation (Cranston) with the $75 non-refundable fee by check or money order (RIGL 5-6-17). Use the DLT's current form.

    Rhode Island DLT: trade license applications and study materials (opens in a new tab)

  3. Wait for your exam notice

    The DLT approves applicants, then mails the date and place of the next sitting. Applications must reach the Division 15 working days before the exam date. Phone 401-462-8580 or 401-462-8526 to confirm the format, what you may bring and the next date.

    Rhode Island DLT: Professional Regulation (opens in a new tab)

  4. Get licensed

    You need an average of at least 70% (rule 260-RICR-30-15-7). The license fee is $72 for a journeyperson or $240 for a contractor, biennial, and renewal needs 15 hours of continuing education (RIGL 5-6-20.1).

    Rhode Island DLT: Professional Regulation (opens in a new tab)RIGL chapter 5-6 (electricians) (opens in a new tab)

How to prepare

  • The DLT publishes no topic weights or question count, so study the NEC broadly: grounding and bonding, wiring methods, services and load calculations, motors.
  • Rhode Island adopted the 2023 NEC with amendments (210.25, 230.24(A) Exception 5 deleted, 230.82 supply-side equipment) effective 12/01/2025. The exam rule says questions follow the edition in force at the time, and the DLT study list names the current NEC (latest state-approved edition) plus general trade knowledge; we couldn't confirm which edition the exam uses today.
  • Exam retakes need a new exam fee.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • 2023 National Electrical Code (NEC), NFPA 70, with Rhode Island amendments (RISBC-5)Essential

    The state-adopted edition from 12/01/2025. Confirm with the DLT which edition your exam uses.

    NFPA (opens in a new tab)

Official reference list (as published by the testing agency)
  • NFPA 70 National Electrical Code with the Rhode Island amendments (RISBC-5, 510-RICR-00-00-5)
  • Rhode Island General Laws chapter 5-6 (electricians)
  • 260-RICR-30-15-7: Board of Examiners of Electricians rules

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Wiring and Protection12
Grounding and Bonding7
Wiring Methods and Materials10
Services, Feeders and Load Calculations8
Motors, Controls and Equipment6
Special Occupancies and Conditions3
Rhode Island Law and Rules4

Exam day details

  • Administered by Rhode Island Department of Labor and Training (Division of Professional Regulation).
  • Fee: $75 application fee to the DLT (RIGL 5-6-17, 5-20-17), non-refundable, by check or money order. Two-year license fees are separate: $240 for a master or contractor, $72 for a journeyperson.
  • Rule 260-RICR-30-15-7 says exams are written, based on the NEC edition the state has adopted at the time of the exam, and may include practical demonstrations.
  • You need an average of at least 70% to be licensed, and at least 60% to review your exam with the Board.
  • The rule disqualifies anyone found referring to notes or books during the exam unless the Board gives permission. Ask the Division what you may bring.
  • The Department of Labor and Training writes and gives this exam on paper at scheduled sittings and mails each approved applicant the date and place. It doesn't publish the number of questions, the time limit or the topic weights.
  • Applications must reach the Division 15 working days before the exam date.
  • A new exam fee applies each time you retake.

Note: The DLT writes and gives this exam itself and publishes no time limit, topic weights or open-book rule, and for electricians no question count. Our timer and topic split (and the electrician length) are practice estimates built from the statutes and the adopted codes. Confirm the format with the DLT (401-462-8580) when you are approved. Rhode Island adopted the 2023 NEC (RISBC-5, effective 12/01/2025) with state amendments, and the electrician exam rule says questions follow the NEC edition adopted at the time of the exam. The DLT study-materials page lists the current NEC (latest state-approved edition) plus general trade knowledge. We could not confirm which edition the DLT exam uses today, so check with the DLT.

Frequently asked questions

How many questions are on the Rhode Island journeyman electrician exam?

The Department of Labor and Training doesn't publish a question count, time limit or topic weights. The rule sets only the scoring: an average of at least 70% to be licensed. Our practice bank uses 50 questions as a working length.

Which NEC does Rhode Island use?

The state adopted the 2023 NEC with Rhode Island amendments effective December 1, 2025. The exam rule says questions follow the edition adopted at the time of the exam; we couldn't confirm the edition on today's DLT exam.

Who gives the exam?

The Department of Labor and Training itself, on paper at scheduled sittings. It isn't a PSI exam.

Free questions with answers

Show all 10 free questions and answers
  1. A branch circuit supplies a continuous load of 28 amperes and no other load. The overcurrent device is not listed for operation at 100 percent of its rating. What is the minimum standard rating of the overcurrent device?

    Answer: 35 amperes

    Continuous loads are taken at 125 percent for the overcurrent device: 28 A x 1.25 = 35 A, which is a standard rating in 240.6(A). Using 30 A ignores the 125 percent rule; 40 A is larger than necessary, and 28 A is not a standard size and ignores the continuous-load multiplier.

    Reference: 2023 National Electrical Code (NFPA 70), 210.20(A); 240.6(A)

  2. A dwelling unit room has receptacle outlets supplied by a 120-volt, 15-ampere branch circuit. Under NEC 2023 210.12(B), in which of these areas must that circuit have AFCI protection?

    Answer: Kitchens, living rooms, bedrooms, closets, hallways and laundry areas, among others listed

    210.12(B) lists the dwelling-unit areas that need AFCI protection, including kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas and similar areas. Bathrooms, garages and outdoors are GFCI locations under 210.8, not AFCI areas, and the wiring method does not control the requirement.

    Reference: 2023 National Electrical Code (NFPA 70), 210.12(B)

  3. A service is supplied by two parallel sets of 3/0 AWG copper conductors per phase (3/0 AWG = 167,800 circular mils). Using Table 250.66 and its note on multiple sets, what is the minimum copper grounding electrode conductor, assuming no connection to a ground rod only or a concrete-encased electrode only?

    Answer: 2 AWG copper

    The note to Table 250.66 says to use the equivalent size from the sum of the areas of parallel conductors: 2 x 167,800 = 335,600 cmil. That is over 3/0 and not over 350 kcmil, so 2 AWG copper applies. Using a single 3/0 conductor would give 4 AWG, which is too small.

    Reference: 2023 National Electrical Code (NFPA 70), Table 250.66, Note 1

  4. At what maximum interval must Type NM cable be secured, and how close to a cabinet or box must the first support be, under 334.30?

    Answer: Every 4-1/2 feet, and within 12 inches of each box

    334.30 requires NM cable to be supported at intervals not exceeding 1.4 m (4-1/2 ft) and within 300 mm (12 in.) of every cable entry into a box, cabinet or fitting. The 10 ft and 3 ft figures belong to EMT in 358.30.

    Reference: 2023 National Electrical Code (NFPA 70), 334.30

  5. A direct-buried Type UF cable is run to a detached garage in a yard, with no concrete or raceway, and no special GFCI protection provision applies. What is the minimum cover required by Table 300.5(A)?

    Answer: 24 inches

    Table 300.5(A), Column 1 gives 600 mm (24 in.) for direct-buried cables or conductors in locations not otherwise specified. Eighteen inches applies to nonmetallic raceways listed for direct burial (Column 3), 6 in. applies to rigid or intermediate metal conduit (Column 2), and 12 in. applies only to residential 120-volt branch circuits of 20 A or less with GFCI protection (Column 4).

    Reference: 2023 National Electrical Code (NFPA 70), Table 300.5(A)

  6. A one-family dwelling has 2,400 square feet of living area. What is the minimum general lighting load under 220.41?

    Answer: 7,200 VA

    220.41 sets the minimum unit load for dwelling units at 3 VA per square foot: 2,400 ft2 x 3 VA = 7,200 VA. The result is then used for branch-circuit counting and, with demand factors from Table 220.45, for service and feeder calculations.

    Reference: 2023 National Electrical Code (NFPA 70), 220.41

  7. In a standard (Part III) dwelling service calculation, the general lighting load is 7,200 VA, the small-appliance circuits are 3,000 VA (two circuits at 1,500 VA) and the laundry circuit is 1,500 VA. What is the demand load for these combined loads using Table 220.45?

    Answer: 6,045 VA

    Add the loads: 7,200 + 3,000 + 1,500 = 11,700 VA (220.52 lets small-appliance and laundry loads be included with the general lighting). Table 220.45: first 3,000 VA at 100 percent = 3,000; remaining 8,700 VA x 0.35 = 3,045. Total = 6,045 VA. The 4,095 VA result applies 35 percent to everything and the 11,700 applies no demand factor.

    Reference: 2023 National Electrical Code (NFPA 70), 220.52; Table 220.45

  8. A 5 hp, 230-volt, three-phase squirrel-cage induction motor runs continuous duty. Using Table 430.250 and 430.22, what is the minimum ampacity of the branch-circuit conductors?

    Answer: 19.0 amperes

    Table 430.250 gives 15.2 A for a 5 hp, 230 V three-phase motor. 430.22 requires conductors at 125 percent of that value: 15.2 x 1.25 = 19.0 A. The 15.2 A figure ignores the 125 percent factor and 17.5 A is the 200 V table value.

    Reference: 2023 National Electrical Code (NFPA 70), Table 430.250; 430.22

  9. What is the maximum time allowed for an emergency system to supply power after failure of the normal source, under 700.12?

    Answer: 10 seconds

    700.12 requires emergency power or lighting to be available within the time required for the application, but not exceeding 10 seconds. Legally required standby systems (Article 701) have a longer allowance and optional standby systems (Article 702) have none specified.

    Reference: 2023 National Electrical Code (NFPA 70), 700.12

  10. Under the Board of Examiners of Electricians rule, what average score must an applicant earn on the written examination to obtain a license?

    Answer: At least 70 percent

    Rule 7.5(C) requires an average of at least 70 percent to obtain a license. An average of at least 60 percent only earns the right to review the examination with the board members.

    Reference: 260-RICR-30-15-7 (Board of Examiners of Electricians), 7.5(C)

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.