Requirements at a glance
| Agency | City of Philadelphia Department of Licenses and Inspections; exam by ICC, delivered by Pearson VUE |
|---|---|
| Exam | ICC 311 Engineer Grade B (refrigeration): 60 questions, 3 hours, open book |
| Experience | 2 years of experience and 2 references from licensed engineers (L&I pages, check current rules) |
| Books allowed | 2021 IMC; 2021 IFGC; 2020 NEC; Modern Refrigeration and Air Conditioning (2000) |
| Fees | $115 to Pearson VUE; Philadelphia Engineer license $63 a year (L&I pages, check current fees) |
Refrigeration engineers applying for a Philadelphia Engineer license, Grade B (refrigeration only), from Licenses and Inspections. Grade A also covers refrigeration but uses a different exam.
Official links
How to get licensed, step by step
Check you qualify
Grade B covers refrigeration only. You need 2 years of experience and 2 references from licensed engineers.
City of Philadelphia: Licenses and Inspections (opens in a new tab)
Schedule exam 311 with Pearson VUE
Book through Pearson VUE ($115). If you fail, wait 10 days to retake.
Schedule with Pearson VUE (ICC exams) (opens in a new tab)ICC: Philadelphia Contractor/Trades Examination Information Bulletin (opens in a new tab)
Pass and apply to L&I
Send your results with your application. Results are valid for 12 months for applying, unless the code edition has changed.
City of Philadelphia: Licenses and Inspections (opens in a new tab)
How to prepare
- Electrical and controls is 20% of the exam. Tab the 2020 NEC articles on motors, air-conditioning and refrigeration equipment (Article 440) and control circuits.
- Tab the 2021 IMC refrigeration chapter and the 2021 IFGC so you can find answers fast in an open-book exam.
- The bulletin also lists Modern Refrigeration and Air Conditioning (2000 edition), which we could not obtain, so check the edition you bring.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IMC and the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 International Mechanical Code (IMC)Essential
Allowed in the exam room. Part of the 311 exam comes from it.
2020 National Electrical Code (NEC), NFPA 70Essential
Allowed in the exam room. Most of the exam comes from it.
2021 International Fuel Gas Code (IFGC)
Allowed in the exam room.
Modern Refrigeration and Air Conditioning, 2000 edition
Listed in the bulletin as an allowed reference. Confirm the edition with ICC.
Official reference list (as published by the testing agency)
- 2021 International Mechanical Code (IMC) (open book)
- 2021 International Fuel Gas Code (IFGC) (open book)
- 2020 National Electrical Code, NFPA 70 (open book)
- Modern Refrigeration and Air Conditioning, 2000 edition (open book)
What's on the exam
Official content outline from International Code Council (ICC), delivered by Pearson VUE (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Theory, Terminology, and General Requirements | 15 | |
| Compressors and Types of Systems | 10 | |
| Evaporators, Condensers, and Cooling Towers | 10 | |
| Piping Inspections and Field Testing | 10 | |
| Air Duct and Insulation | 10 | |
| Electrical and Controls | 20 | |
| Refrigerants | 10 | |
| Operation Procedures | 5 | |
| Maintenance Repairs | 10 |
The outline totals 100; the other items on the 60-question exam are unscored or unassigned.
Exam day details
- Administered by International Code Council (ICC), delivered by Pearson VUE for the City of Philadelphia Department of Licenses and Inspections.
- Fee: $115 to Pearson VUE. City of Philadelphia license fees are separate.
- 60 questions in 3 hours, open book. The bulletin lists the 2021 IMC, 2021 IFGC, 2020 NEC and the 2000 edition of Modern Refrigeration and Air Conditioning.
- Electrical and controls is the largest area at 20%, followed by theory, terminology and general requirements at 15%.
- Philadelphia Engineer licenses need 2 years of experience and 2 references from licensed engineers (L&I pages, check current rules).
- ICC writes the exam and Pearson VUE delivers it. Every question is four-option multiple choice with one correct answer.
- If you fail, you must wait 10 days before you retake the exam.
- The ICC Philadelphia bulletin does not print a passing score. TODO(verify): confirm the passing score with ICC before you sit.
- Philadelphia's published exam results are valid for 12 months for applying, unless the code edition has changed.
Frequently asked questions
What's on the Philadelphia refrigeration engineer exam?
ICC exam 311: electrical and controls 20%, theory, terminology and general requirements 15%, and compressors, evaporators and condensers, piping inspections, air duct and insulation, refrigerants and maintenance repairs 10% each, with operation procedures 5%.
Is the exam open book?
Yes. The ICC Philadelphia bulletin lists it as open book with the 2021 IMC, 2021 IFGC, 2020 NEC and Modern Refrigeration and Air Conditioning (2000).
What is the difference between Grade A and Grade B?
Per L&I, Grade B is refrigeration only. Grade A covers steam, stationary and refrigeration engineering and uses a separate exam.
Free questions with answers
Show all 10 free questions and answers
Under the 2021 IMC definitions, a refrigeration capacity rating of 1 ton is equal to how many Btu per hour?
Answer: 12,000 Btu/h
The Chapter 2 definition of Refrigeration Capacity Rating says 1 horsepower, 1 ton and 12,000 Btu/h all mean the same quantity. A ton is the heat needed to melt one ton (2,000 lb) of ice in 24 hours: 2,000 lb x 144 Btu/lb = 288,000 Btu, divided by 24 h = 12,000 Btu/h. 24,000 Btu/h is a 2-ton machine, and 144,000 is a mis-scaled figure (144 Btu/lb x 1,000).
Reference: 2021 International Mechanical Code, Chapter 2, Definitions: Refrigeration Capacity Rating
A walk-in cooler room has an enclosed volume of 8,000 cubic feet and is the smallest occupied space the system serves. Table 1103.1 lists R-744 at 3.4 pounds per 1,000 cubic feet. What is the table amount for that space?
Answer: 27.2 pounds
Table 1103.1 gives the amount per 1,000 cubic feet. 8,000 ft3 / 1,000 = 8, and 8 x 3.4 lb = 27.2 lb. Dividing instead of multiplying gives about 2.4, and misplacing the decimal gives 272 or 34. Section 1104.4.1 says to use the volume of the smallest enclosed occupied space.
Reference: 2021 International Mechanical Code, Table 1103.1; Section 1104.4.1
Under Section 1108.3.3 of the 2021 IMC, soldered joints in refrigerant piping are limited to systems that meet which conditions?
Answer: Group A1 refrigerant and a pressure of 200 psi or less
Section 1108.3.3 limits solder joints to refrigerant systems using Group A1 refrigerant at a pressure of 200 psi (1378 kPa) or less. The flux must conform to ASTM B813 and the solder to ASTM B32. Higher pressures or flammable or toxic groups require brazed or other approved joints.
Reference: 2021 International Mechanical Code, Section 1108.3.3
Under Section 604.3 of the 2021 IMC, what maximum flame spread index and smoke-developed index must duct coverings and linings have when tested to ASTM E84 or UL 723?
Answer: Flame spread 25 and smoke-developed 50
Section 604.3 limits duct coverings and linings, including adhesives, to a flame spread index of not more than 25 and a smoke-developed index of not more than 50. The 450 smoke index belongs to the spray polyurethane foam exception for ducts in attics and crawl spaces. Coverings and linings must also be listed and labeled.
Reference: 2021 International Mechanical Code, Section 604.3
A single hermetic motor-compressor has a nameplate rated-load current of 24 A and no branch-circuit selection current is marked. What is the minimum ampacity of the branch-circuit conductors under Section 440.32?
Answer: 30 A
Section 440.32 requires conductors supplying a single motor-compressor to have an ampacity of at least 125 percent of the rated-load current (or the branch-circuit selection current, if greater): 24 A x 1.25 = 30 A. 24 A is the current with no factor, 27.6 A uses 115 percent (the disconnect factor), and 33.6 A uses 140 percent (the overload relay factor).
Reference: 2020 National Electrical Code (NFPA 70), Section 440.32
Where must the disconnecting means for air-conditioning or refrigerating equipment be located, under Section 440.14?
Answer: Within sight of, and readily accessible from, the equipment
Section 440.14 requires the disconnecting means to be within sight from, and readily accessible from, the air-conditioning or refrigerating equipment, and it may be installed on or within the equipment. It may not be located on panels designed to allow access to the equipment or obscure the nameplate. The exceptions cover lockable disconnects for industrial process equipment and plug-and-receptacle disconnects.
Reference: 2020 National Electrical Code (NFPA 70), Section 440.14
A supermarket refrigeration system has a full charge of 200 pounds of R-22 (a class II refrigerant). Under the 40 CFR 82.152 annualizing method, 40 pounds were added to return it to full charge, and 146 days had passed since refrigerant was last added. What is the leak rate?
Answer: 50 percent
Annualizing method: Step 1, 40 / 200 = 0.20. Step 2, 146 / 365 = 0.40. Step 3, 0.20 / 0.40 = 0.50. Step 4, 0.50 x 100 = 50 percent. 20 percent leaves out the time adjustment, 8 percent multiplies 0.20 by 0.40 instead of dividing, and 200 percent divides the steps the wrong way round (0.40 / 0.20). Since April 10, 2020, Section 82.157 applies only to appliances with 50 pounds or more of a class I or class II refrigerant, such as R-22; a rate over 20 percent for commercial refrigeration triggers repair under 82.157(c).
Reference: 40 CFR Part 82, Subpart F (Section 608 refrigerant management), 40 CFR 82.152 (Leak rate, Annualizing Method); 82.157(c)
At what refrigerant concentration must the compressors and pumps in a machinery room be shut off automatically under Section 1106.5.1 of the 2021 IMC?
Answer: Above the detector's upper detection limit or 25 percent of the LEL, whichever is lower
Section 1106.5.1 says the equipment must be automatically shut off whenever the vapor concentration in the machinery room exceeds the detector's upper detection limit or 25 percent of the LEL, whichever is lower, in addition to the manual break-glass switch. Detectors in machinery rooms are required by Section 1105.3 (IFC 608.9 and 608.18).
Reference: 2021 International Mechanical Code, Section 1106.5.1; Section 1105.3
An absorption refrigeration system differs from a mechanical vapor-compression system in the 2021 IMC definitions because it:
Answer: Uses heat in a generator and an absorber in place of a mechanical compressor
The Chapter 2 definition of an absorption system says refrigerant is pressurized by pumping a chemical solution of refrigerant in absorbent, separated by adding heat in a generator, condensed, expanded, evaporated and reabsorbed in an absorber. The Refrigeration System, Mechanical definition requires a compressor for the refrigerant vapor, which absorption systems lack.
Reference: 2021 International Mechanical Code, Chapter 2, Definitions: Absorption System; Refrigeration System, Mechanical
A refrigerant evaporator coil is located in an air duct serving three enclosed occupied spaces. Airflow to the smallest space, 2,500 cubic feet, can be reduced below one-quarter of its maximum by dampers. Under Section 1104.4.2 of the 2021 IMC, which volume sets the allowable refrigerant quantity?
Answer: The volume of the smallest enclosed occupied space served, 2,500 cubic feet
Section 1104.4.2 uses the volume of the smallest enclosed occupied space served by the duct system. Its exception, which allows the entire space served by the duct system to be used, applies only where airflow to the enclosed spaces cannot be reduced below one-quarter of its maximum; here dampers can cut airflow to the smallest space below that, so its 2,500 cubic feet governs. Where the space above a suspended ceiling is part of the supply or return plenum, that space is counted too (Section 1104.4.3).
Reference: 2021 International Mechanical Code, Sections 1104.4.2 and 1104.4.3
Sources
- ICC: Philadelphia Contractor/Trades Examination Information Bulletin (3/15/2026) (opens in a new tab)
- Pearson VUE: ICC exams (opens in a new tab)