Requirements at a glance
| Agency | North Dakota State Plumbing Board; state-administered exam |
|---|---|
| Experience | 4 years as an apprentice under a licensed master plumber (7,600 hours at 1,900 a year) |
| Exam | Five parts in 5 hours (100 closed-book multiple-choice questions plus completion and sizing parts); 70% to pass |
| Books allowed | 2018 North Dakota Plumbing Code (you bring it); multiple-choice part closed book, completion parts open book |
| Fees | $50 application, $50 exam, plus the license fee ($100 journeyman, $200 master) |
Apprentices with 4 years of experience under a licensed master plumber (7,600 hours at 1,900 hours a year), and journeymen licensed in other states who want a North Dakota license.
Official links
How to get licensed, step by step
Apply to the Board
Submit the application with the $50 fee and proof of experience. The application expires if you do not test within 6 months of approval.
Schedule your exam
Exams are given every other month. You need a current North Dakota license or an application on file to be eligible. The exam fee is $50.
Plumbing Board: exam general information (opens in a new tab)
Pass every part
Bring the 2018 North Dakota Plumbing Code, a calculator and photo ID. You have 5 hours.
Plumbing Board: exam general information (opens in a new tab)
If you fail
Wait 6 months from your last exam before retesting (NDAC 62-02-01-04).
How to prepare
- North Dakota uses the 2018 Uniform Plumbing Code as the 2018 North Dakota Plumbing Code: chapters 1 to 4, 6 to 11 and 17 and appendices A, B, C, D, E, I and M. Water heaters (Chapter 5) and chapters 12 to 16 are not adopted, so skip them.
- The exam has a closed-book multiple-choice part plus open-book completion questions and pipe-sizing drawings. Our questions cover the multiple-choice style and sizing arithmetic; practice drawings from your code book.
- Learn fixture-unit values, trap and vent sizes and drain sizing from the 2018 tables. The Board publishes no topic weights, so our split is an estimate.
- The journeyman exam adds a closed-book drain, waste and vent pipe sizing part, so memorize the common fixture-unit values and drain sizes.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
2018 North Dakota Plumbing Code (Uniform Plumbing Code 2018, IAPMO)Essential
You bring your own code book. North Dakota adopted chapters 1 to 4, 6 to 11 and 17 and appendices A, B, C, D, E, I and M only.
Plumbing Board (code books) (opens in a new tab)Read free: 2018 UPC (IAPMO) (opens in a new tab)
Official reference list (as published by the testing agency)
- 2018 North Dakota Plumbing Code: the 2018 Uniform Plumbing Code (IAPMO) chapters 1 to 4, 6 to 11 and 17 and appendices A, B, C, D, E, I and M. Chapter 5 (water heaters) and chapters 12 to 16 are not adopted. The examinee brings the code book.
- NDAC 62-03.1: North Dakota plumbing code rules (private sewage disposal, NDAC 62-03.1-03)
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Chapters 1 and 2: Administration and Definitions | 5 | |
| Chapter 3: General Regulations | 9 | |
| Chapter 4: Plumbing Fixtures and Fixture Fittings | 10 | |
| Chapter 6: Water Supply and Distribution | 12 | |
| Chapter 7: Sanitary Drainage | 13 | |
| Chapter 8: Indirect Wastes | 3 | |
| Chapter 9: Vents | 11 | |
| Chapter 10: Traps and Interceptors | 6 | |
| Chapter 11: Storm Drainage | 6 | |
| Water Pipe Sizing (Chapter 6 and Appendices A and M) | 12 | |
| Drain, Waste and Vent Sizing with Fixture Units | 13 |
Exam day details
- Administered by the North Dakota State Plumbing Board (state-administered exam).
- Fee: $50 per exam (NDAC 62-02-01-02). The $50 application fee and the license fee ($100 journeyman, $200 master) are separate.
- Five parts in 5 hours. Parts 1 and 2 are closed book: 100 multiple-choice questions and a drain, waste and vent pipe sizing completion. Parts 3 to 5 are open book: 40 completion questions, a water pipe sizing completion and a drain, waste and vent with fixture units completion. 70% to pass (NDAC 62-02-01-03).
- The exam mixes multiple-choice questions with completion questions and pipe-sizing drawings. This site can only practice the multiple-choice style, so use the sizing questions as a warm-up for the drawings.
- The multiple-choice part is closed book, so learn the common fixture-unit values and trap and vent sizes. The completion and sizing parts are open book.
- The application expires if you do not test within 6 months of approval. After a failed exam you must wait 6 months to retest (NDAC 62-02-01-04).
- Exams are given every other month. Licensees must hold a current ND license or have an application in to be eligible to test.
- Only the adopted chapters are tested. We do not ask about water heaters (Chapter 5) or fuel gas piping (Chapter 12), which North Dakota did not adopt.
Note: The Plumbing Board prints the exam structure (a 100-question multiple-choice part plus completion and sizing parts) but no topic weights, so our topic split is an estimate. Table values come from the 2018 UPC; confirm sizing tables in your code book.
Frequently asked questions
What's on the North Dakota journeyman plumber exam?
Five parts: 100 closed-book multiple-choice questions, a closed-book drain, waste and vent pipe sizing, 40 open-book completion questions, an open-book water pipe sizing and an open-book drain, waste and vent with fixture units drawing. The Board publishes no topic weights, so our split is an estimate.
Which plumbing code does North Dakota use?
The 2018 North Dakota Plumbing Code, which is the 2018 Uniform Plumbing Code chapters 1 to 4, 6 to 11 and 17 and appendices A, B, C, D, E, I and M. Water heaters (Chapter 5) and chapters 12 to 16 are not adopted.
How long do I wait to retest?
Six months from the date of your last examination (NDAC 62-02-01-04).
Free questions with answers
Show all 10 free questions and answers
A plumbing permit was issued, but the contractor never started the work. After how many days from the date of the permit does it expire by limitation?
Answer: 180 days
Section 104.4.3 voids a permit when the work is not commenced within 180 days of issue, or when work is suspended or abandoned for 180 days after starting. The shorter periods are not in the section, and one year is not the limit either.
Reference: 2018 Uniform Plumbing Code, Section 104.4.3
PEX water tubing passes through a stud and ends up less than 1 inch from the exposed face of the framing. What is the minimum thickness of the steel nail plate required?
Answer: No. 18 gauge (0.0478 inch)
Section 312.9 requires plastic or copper piping that comes within 1 inch of the exposed framing to be protected by a steel nail plate not thinner than No. 18 gauge (0.0478 inch), extending at least 1-1/2 inches beyond the pipe outside diameter. Higher gauge numbers are thinner steel and do not comply; No. 14 is thicker than required but is not what the section states.
Reference: 2018 Uniform Plumbing Code, Section 312.9
What is the maximum water consumption allowed for a water closet under Section 411.2 of the 2018 UPC?
Answer: 1.6 gallons per flush
Section 411.2 limits water closets to 1.6 gallons (6.0 L) per flush, and Section 411.2.2 applies the same 1.6 gallon limit to flushometer valve activated closets. Urinals are limited to 1 gallon per flush (412.1), so that value is the trap. The 3.5 gallon figure is an obsolete older standard.
Reference: 2018 Uniform Plumbing Code, Section 411.2
The water main cannot deliver enough pressure, and after friction and other losses the residual pressure at the fixtures would be 12 psi. Under Section 608.1, what is required?
Answer: A tank and pump or other means that will provide at least 15 psi residual
Section 608.1 requires a tank and pump or other means providing not less than 15 psi residual pressure where the main cannot supply that after allowing for friction and other losses. The 25 psi figure and a 12 psi allowance are not in the section, and a regulator only reduces pressure.
Reference: 2018 Uniform Plumbing Code, Section 608.1
Because of structural conditions, a 4 inch horizontal drain cannot be laid at 1/4 inch per foot. What does Section 708.1 allow?
Answer: 1/8 inch per foot, where first approved by the Authority Having Jurisdiction
Where 1/4 inch per foot is impractical, Section 708.1 lets piping 4 inches or larger be run at not less than 1/8 inch per foot (1 percent) if the Authority Having Jurisdiction approves first. Pipe smaller than 4 inches has no such allowance.
Reference: 2018 Uniform Plumbing Code, Section 708.1
A fixture vent must rise before it can turn horizontal. How far above the flood-level rim of the fixture served must it rise first, under Section 905.3?
Answer: At least 6 inches
Section 905.3 requires each vent, unless structural conditions prevent it, to rise vertically to at least 6 inches above the flood-level rim of the fixture served before offsetting horizontally, so a blocked drain cannot back up into the vent.
Reference: 2018 Uniform Plumbing Code, Section 905.3
A 4 inch trap arm changes direction horizontally by 120 degrees in total. What does Section 1002.3 say about a cleanout?
Answer: None is required, because for 3 inch and larger arms the limit is 135 degrees
Section 1002.3 permits a trap arm to change direction up to 90 degrees without a cleanout, but its exception raises the limit to 135 degrees for trap arms 3 inches and larger. A 120 degree change in a 4 inch arm is within the exception, so no cleanout is required.
Reference: 2018 Uniform Plumbing Code, Section 1002.3
What is the minimum diameter of a perforated subsoil drain around a building with a basement under Section 1101.6?
Answer: 3 inches
Section 1101.6 requires subsoil drains of perforated or open-jointed approved pipe or tile, not less than 3 inches in diameter, laid in gravel or other porous material around buildings with basements, cellars, crawl spaces or floors below grade.
Reference: 2018 Uniform Plumbing Code, Section 1101.6
A house totals 24.5 WSFU. Static pressure after head loss is 46 to 60 psi, the meter is 3/4 inch, and the longest developed length is 100 feet. Using Table 610.4, what is the smallest building supply size?
Answer: 1 inch
In the 46 to 60 psi block with a 3/4 inch meter, the 100 foot column allows 17 fixture units on a 3/4 inch supply, 33 on a 1 inch supply and 39 on a 1-1/4 inch supply. The Section 610.4 procedure says to follow down the column to a value equal to or exceeding the total, so 24.5 needs the 1 inch supply (33). A 3/4 inch supply carries only 17, and no building supply may be under 3/4 inch.
Reference: 2018 Uniform Plumbing Code, Section 610.4 and Table 610.4
A 2 inch vertical drainage stack is limited by length as well as load in Table 703.2. What is the maximum length of a 2 inch vertical drainage pipe?
Answer: 85 feet
Table 703.2 lists maximum vertical drainage lengths of 45 feet for 1-1/4 inch, 65 feet for 1-1/2 inch, 85 feet for 2 inch and 212 feet for 3 inch pipe. A 2 inch stack carries up to 16 units subject to footnote 3.
Reference: 2018 Uniform Plumbing Code, Table 703.2
Sources
- North Dakota State Plumbing Board: exam general information (opens in a new tab)
- North Dakota State Plumbing Board (laws and rules, NDAC 62-02-01) (opens in a new tab)
Questions last verified November 7, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.