North Carolina licensing exam

North Carolina Plumbing Contractor Exam: Practice Test & Licensing Guide

The PSI exam for North Carolina Class I and Class II plumbing contractor licenses: a 4-hour open-book exam on the 2018 NC Plumbing, Administrative, Energy and Residential Codes.

Questions
Not published by North Carolina
Time limit
4 hours
Passing score
Not published by North Carolina

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Administration, Definitions and General Regulations

Under the Section 202 definition in the 2018 NC Plumbing Code, the water service pipe runs from the water main (or from the meter when the meter is at the public right of way) to what point?

Requirements at a glance

AgencyNC State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors; exams by PSI
ExamPlumbing contractor exam, 4 hours, open book (question count and pass score are not published)
Books allowed2018 NC Plumbing, Administrative, Energy and Residential Codes (per your class list)
Fees$150 by examination: $75 Board application plus $75 nonrefundable PSI exam fee (valid one year), per 21 NCAC 50 .1101(c); then the annual license fee ($150 for contractors, .1102)

Anyone qualifying a Plumbing Class I or Class II contractor license from the NC State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors.

How to get licensed, step by step

  1. Apply to the Board

    Contact the Board (1109 Dresser Court, Raleigh; 919-875-3612) and submit the exam application for your license type.

    NC State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors (opens in a new tab)

  2. Wait for PSI's email

    Once approved you get an email confirmation from PSI, then register and pay the $75 exam fee (the $75 application fee goes to the Board). After you pass, pay the license fee ($150 a year for contractors) within 45 days.

    Schedule with PSI (NC plumbing, heating and fire sprinkler) (opens in a new tab)

  3. Check your book list

    Only the books for your exam category are allowed in the room. The Board's list is effective July 1, 2025; confirm it before you buy.

    NC Board: exam information, book list and 2018 code notice (opens in a new tab)NC Office of State Fire Marshal: code book sales (opens in a new tab)

  4. Take the exam and Business and Law

    Business and Law is a separate Board exam unless you hold an active license and passed it after August 2003.

    Schedule with PSI (NC plumbing, heating and fire sprinkler) (opens in a new tab)

How to prepare

  • North Carolina's exams use the 2018 NC State Building Code (2015 ICC base text with NC amendments, effective 2019). The 2024 NC codes are delayed to no earlier than May 1, 2027, so use the 2018 books.
  • Tab your books with permanent tabs before exam day. Highlighting is allowed; writing, sticky flags and loose papers are not.
  • Tab the 2018 NC Plumbing Code chapters on drainage, vents and water supply sizing tables.
  • The Board supplies the NC Heating and Plumbing Figures at the test site; study the sizing tables beforehand.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 NC Plumbing Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • North Carolina State Building Code: Plumbing Code, 2018 (2015 IPC with NC amendments)
  • North Carolina State Building Code: Administrative Code and Policies, 2018
  • North Carolina State Building Code: Energy Conservation Code, 2018
  • North Carolina State Building Code: Residential Code, 2018
  • Which of these apply depends on your license class; check the Board's Book Reference List before you buy

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Administration, Definitions and General Regulations8
Fixtures, Faucets and Fittings10
Water Heaters6
Water Supply and Distribution16
Sanitary Drainage16
Vents12
Traps, Interceptors and Special Piping6
Storm Drainage6
Piping Materials, Joints and Testing8
Energy and Residential Code Requirements6
Board Rules and Business Practices6

Exam day details

  • Administered by PSI Services for the NC State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors.
  • Fee: $150 for a license by examination (21 NCAC 50 .1101(c)): $75 Board application fee plus $75 nonrefundable exam fee paid to PSI (valid one year). After you pass, pay the annual license fee ($150 for a contractor license, .1102).
  • 4 hours, open book. The Board does not publish the number of questions, the pass score or a topic outline.
  • Class I and Class II contractors are tested on class-specific book lists; the class columns of the Board's matrix did not extract cleanly, so confirm your list on the Board's site.
  • Plumbing, heating and fire sprinkler exams are based on the 2018 NC codes until the 2024 codes take effect (no earlier than May 1, 2027).
  • Open book: bring your own reference books in original published condition (hard-, spiral- or ring-bound), only the books listed for your exam. Highlighting and permanent commercial tabs (ICC Turbo Tabs are the only loose inserts) are allowed; writing, underlining, notes and homemade tabs are not. Printed PDFs are not allowed.
  • PSI provides pencils, scratch paper, calculators and the NC Heating and Plumbing Figures. Heating candidates bring their own duct calculator.
  • You must apply to the Board first; PSI emails you after approval. A license by examination costs $150 ($75 application fee plus a $75 nonrefundable exam fee paid to PSI, valid one year); after you pass, the annual license fee ($150 for contractors) is due within 45 days.
  • You cannot retest the same day. Unauthorized materials in the exam room mean a 90-day wait before you can reschedule.
  • Business and Law is a separate exam, not required if you hold an active license and passed the Board's Business and Law exam after August 2003.

Note: The Board publishes exam durations and reference books for each exam but not the number of questions, a pass score or a topic outline. The question count, pass score and topic weights on this page are our practice estimates. The Board's note dated June 1, 2026 says exams stay on the 2018 NC codes (including NFPA 13 and 13D 2013 and NFPA 25 2011) until the 2024 codes take effect, no earlier than May 1, 2027.

Frequently asked questions

How many questions are on the NC plumbing contractor exam?

The Board and PSI publish only the 4-hour time limit. This practice exam uses 80 questions as a working length.

Which codes does it use?

The 2018 NC Plumbing Code, 2018 Administrative Code and Policies, and the 2018 Energy and Residential Codes as listed for your class.

Is there a journeyman plumber exam?

No. North Carolina tests plumbing contractors (Class I and II, plus restricted limited and plumbing technician categories on the Board's book list).

Free questions with answers

Show all 10 free questions and answers
  1. Under the Section 202 definition in the 2018 NC Plumbing Code, the water service pipe runs from the water main (or from the meter when the meter is at the public right of way) to what point?

    Answer: To the water distribution system of the building served

    The integrated 2018 NC Plumbing Code defines the water service pipe as the pipe from the water main or other potable source, or from the meter when the meter is at the public right of way, to the water distribution system of the building served. The water distribution pipe then carries water within the structure or premises to the points of use.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Section 202 General Definitions, Water service pipe

  2. In North Carolina, what is the minimum compartment size for a wall-hung water closet under Section 405.3.1?

    Answer: 30 inches wide by 56 inches deep

    The NC text of 405.3.1 sets compartments at not less than 30 inches wide and 60 inches deep for floor-mounted closets, and 30 inches wide and 56 inches deep for wall-hung closets. Using 60 inches for a wall-hung bowl is the common mix-up.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Section 405.3.1 (NC amendment)

  3. The temperature relief valve on a storage water heater must be located so that it senses water in what part of the tank, according to Section 504.4.1?

    Answer: The top 6 inches of the tank

    Section 504.4.1 requires the valves in the shell of the tank with the temperature relief valve actuated by the water in the top 6 inches, where the hottest water collects. There must be no check or shutoff valve between the relief valve and the tank.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Section 504.4.1 Installation

  4. Under the North Carolina text of Section 604.5, how far from the point of connection to the fixture must the fixture supply pipe terminate?

    Answer: Not more than 36 inches

    NC amended Section 604.5 so the fixture supply pipe terminates not more than 36 inches from the point of connection to the fixture, with an exception for residential dishwashers and ice makers. The 30-inch limit is the base 2015 IPC value that NC replaced.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Section 604.5 Size of fixture supply (NC text)

  5. What is the minimum slope for a horizontal drain pipe 3 inches to 6 inches in diameter under Table 704.1?

    Answer: 1/8 inch per foot

    Table 704.1 requires 1/4 inch per foot for pipes 2 1/2 inches or smaller, 1/8 inch per foot for 3 to 6 inches, and 1/16 inch per foot for 8 inches or larger.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Table 704.1 Slope of horizontal drainage pipe

  6. An open vent terminal is 6 feet horizontally from an openable window. What does the North Carolina text of Section 903.5 require?

    Answer: The terminal must be at least 2 feet above the top of the window opening

    NC Section 903.5 bars a vent terminal directly beneath a door, openable window, air intake or property line, and a terminal within 10 feet horizontally of such an opening must be 2 feet or more above the top of the opening. At 6 feet the terminal is inside the 10-foot zone. The 3-foot figure is the base 2015 IPC value that NC reduced to 2 feet.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Section 903.5 Location of vent terminal (NC text)

  7. A garage drains 500 square feet of floor area to an oil separator, and Section 1003.4.2.2 applies. What minimum separator capacity is required?

    Answer: 10 cubic feet

    Section 1003.4.2.2 requires 6 cubic feet for the first 100 square feet plus 1 cubic foot for each additional 100 square feet. Additional area = 500 - 100 = 400 sq ft, so 4 cubic feet; 6 + 4 = 10 cubic feet. Using 1 cubic foot per 100 sq ft on the full area gives 11.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Section 1003.4.2.2 Garages and service stations

  8. A horizontal building storm drain laid at 1/4 inch per foot (2-percent slope) serves 5,000 square feet of roof where the design rainfall rate is 4 inches per hour. Using NC Table 1106.3, what is the smallest pipe size?

    Answer: 6 inches

    North Carolina replaced the 2015 IPC gpm sizing table with roof-area tables. In NC Table 1106.3, the 1/4-inch-per-foot rows in the 4 in/h column allow 5 inches = 4,720 sq ft and 6 inches = 7,550 sq ft. 4,720 is less than 5,000, so 6 inches is the smallest size. Reading the 1/2-inch-per-foot rows (5 inches = 6,680 sq ft) wrongly gives 5 inches.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Section 1106.3 and Table 1106.3 Size of horizontal storm drainage piping (NC text)

  9. What is the maximum horizontal hanger spacing for PVC pipe under Table 308.5?

    Answer: 4 feet

    Table 308.5 lists PVC pipe at 4 feet horizontal and 10 feet vertical. Copper tubing 1 1/4 inches and smaller is 6 feet horizontal, and steel pipe is 12 feet.

    Reference: 2018 North Carolina Plumbing Code (2015 IPC with NC amendments), Table 308.5 Hanger spacing

  10. Under the 2015 IRC base text used in the NC Residential Code, which fixtures must every dwelling unit have according to Section R306.1?

    Answer: A water closet, a lavatory, and a bathtub or shower

    Section R306.1 requires a water closet, lavatory, and a bathtub or shower in every dwelling unit. Section R306.2 separately requires a kitchen sink.

    Reference: 2018 North Carolina Residential Code (2015 IRC base text), Section R306.1 Toilet facilities

Sources

Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.