Requirements at a glance
| Agency | Nevada State Contractors Board (NSCB); exams by PSI |
|---|---|
| Experience | 4 years as a journeyman, foreman, supervisor or contractor in the classification within the last 15 years (up to 3 years can be education) |
| Exams | 80 questions, 4 hours, 70%, plus the Construction Management Survey (business and law) |
| Books allowed | 2017 NEC and NFPA 72 (2010 or 2013) |
| Fees | $95 per PSI exam ($140 for a trade exam plus the CMS), plus NSCB application and license fees and a bond |
Qualifying individuals for a Nevada C-2 Electrical contractor license, which covers any electrical wiring, fixtures, apparatus and raceways.
Official links
How to get licensed, step by step
Pick your classification
Find the NSCB classification that covers your work, and name the qualifying individual (an owner or a qualified employee) with 4 years of experience in it.
Apply to the NSCB
Submit the application with your experience verification, financial statement and fingerprints. The Board sends you an exam eligibility notice once it accepts your qualifications.
Schedule the CMS and C-2 trade exam with PSI
Book both exams with PSI. Bring the allowed references, tabbed. If you fail, wait 2 weeks; you get three attempts and must pass within 6 months of filing.
Schedule with PSI (Nevada contractors) (opens in a new tab)PSI: Nevada "C" classification bulletin and outlines (opens in a new tab)
Post your bond and get licensed
After you pass, the Board sets your monetary limit and bond amount ($1,000 to $500,000). File the bond and pay the license fee to receive your license.
How to prepare
- Bring the exact editions on PSI's outline. Nevada's trade exams use the 2017 NEC, the 2018 IBC/IRC and the 2018 UPC/UMC; a newer book gives some wrong answers.
- Tab your books with permanent tabs before exam day. Sticky notes are removed at check-in, and you can't write in the books.
- OSHA 1926 isn't allowed in the room, but every trade exam has a safety section from it. Learn the common numbers (fall protection at 6 ft, ladders 3 ft above the landing, trenches 5 ft).
- The ampacity table is 310.15(B)(16) in the 2017 NEC and load calculations are in Article 220. Tab them.
- Safety (8) and transmission lines (5) come mostly from OSHA 1926 Subparts K and V: approach distances, lockout and grounding for line work.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2017 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code, 2017 EditionEssential
The edition PSI's Nevada outline lists (the 2017 NEC Handbook is also allowed). Newer editions renumber key tables and rules.
NFPA 72: National Fire Alarm Code, 2010 or 2013 Edition
Allowed in the room; source of the 2 fire alarm questions.
29 CFR 1926 (OSHA Construction Standards), sections on your reference list
Not allowed in the room, but every Nevada trade exam has safety questions written from it: fall protection, scaffolds, ladders, excavations.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (or NEC Handbook), 2017 (allowed in the exam room)
- NFPA 72: National Fire Alarm Code (or Handbook), 2010 or 2013 (allowed in the exam room)
- 29 CFR Part 1926, OSHA Construction (not allowed in the room)
- Ugly's Electrical References; National Electrical Safety Code 2012; Lineman's and Cableman's Handbook, 14th ed. (not allowed in the room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 6 | |
| Service, Feeders, and Branch Circuits | 7 | |
| Grounding and Bonding | 7 | |
| Conductors and Cables | 8 | |
| Raceways and Boxes | 7 | |
| Special Occupancies and Equipment | 5 | |
| Electrical Power | 6 | |
| Motors | 6 | |
| Low Voltage | 2 | |
| Lighting | 5 | |
| Illuminated Signs | 2 | |
| Fire Detection and Alarm Systems | 2 | |
| Safety Information | 8 | |
| Transmission Lines | 5 | |
| Overcurrent Protection | 4 |
Exam day details
- Administered by PSI Services for the Nevada State Contractors Board (NSCB).
- Fee: $95 to PSI for one exam, $140 for a trade exam plus the CMS. NSCB application and license fees are separate.
- 80 questions in 4 hours; 56 correct (70%) to pass.
- The exam uses the 2017 NEC, not the newest edition. Bring the 2017 code book.
- Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed.
- PSI may add up to 10 unscored trial questions, which count against your time.
- If you fail, wait 2 weeks to retake. You get three attempts, and you must pass within 6 months of filing your application; a third failure voids the application.
- Every Nevada contractor license needs both the Construction Management Survey (business and law) and the trade exam for the classification, plus 4 years of experience in the last 15.
Frequently asked questions
Which NEC edition is the Nevada C-2 exam based on?
The 2017 NEC. PSI's outline says code questions use only the listed edition, so a newer code book can give you wrong answers.
What's on the Nevada C-2 electrical exam?
80 questions. The biggest areas are conductors and cables (8) and safety (8), then services, feeders and branch circuits, grounding and bonding, and raceways and boxes (7 each). It also has 5 questions on transmission lines.
Does Nevada have a state journeyman electrician license?
No. The Nevada State Contractors Board licenses electrical contracting businesses; the qualifying individual takes this exam and the business and law exam. Some counties, such as Clark County, issue their own journeyman cards.
Free questions with answers
Show all 10 free questions and answers
Using Table 220.12 of the 2017 NEC, what is the general lighting load for a 12,000 sq ft office building?
Answer: 42,000 VA
Table 220.12 in the 2017 NEC assigns office buildings 3-1/2 VA per square foot: 12,000 × 3.5 = 42,000 VA. The 2020 NEC reduced office lighting to 1.3 VA/sq ft (15,600 VA here), but the Nevada exam uses the 2017 edition. 36,000 VA uses 3 VA (stores and schools).
Reference: NFPA 70, National Electrical Code, 2017, 220.12, Table 220.12
Under 240.21(B)(1), a 10-ft feeder tap leaves the enclosure where the tap is made (field installed) from a 600-A feeder. What is the minimum ampacity of the tap conductors?
Answer: 60 A
240.21(B)(1) (the 10-ft tap rule) requires tap conductor ampacity at least equal to the calculated load and the rating of the device the tap supplies, and, for field installations where the tap leaves the enclosure, at least one-tenth of the rating of the overcurrent device protecting the feeder: 600 ÷ 10 = 60 A. The 25-ft tap rule (240.21(B)(2)) requires one-third (200 A).
Reference: NFPA 70, National Electrical Code, 2017, 240.21(B)(1)
A balanced 45-kW resistive heating load is supplied at 480 V, 3-phase. What is the line current?
Answer: 54.1 A
For a balanced 3-phase load, I = P ÷ (E × 1.732) = 45,000 ÷ (480 × 1.732) = 45,000 ÷ 831.4 = 54.1 A. 93.8 A divides by 480 only (single-phase formula), and 31.3 A divides by 3 × 480.
Reference: General electrical theory, Three-phase power: I = P ÷ (E × √3)
A feeder is protected by a 600-A breaker. Using Table 250.122, what is the minimum copper equipment grounding conductor?
Answer: 1 AWG
Table 250.122 requires 1 AWG copper for overcurrent devices rated 600 A. 400 A requires 3 AWG, 500 A requires 2 AWG, and 800 A requires 1/0 AWG. The EGC is sized on the overcurrent device rating, not the conductor size.
Reference: NFPA 70, National Electrical Code, 2017, Table 250.122
Nine current-carrying 10 AWG THHN copper conductors are in one conduit in a normal ambient. What is each conductor's adjusted ampacity using the 90°C column (before any termination limit)?
Answer: 28.0 A
10 AWG THHN at 90°C = 40 A (Table 310.15(B)(16)). For 7–9 current-carrying conductors, Table 310.15(B)(3)(a) applies 70%: 40 × 0.70 = 28.0 A. 32 A uses 80% (4–6 conductors). The result must still respect the 30-A overcurrent limit of 240.4(D) for 10 AWG and the terminal rating.
Reference: NFPA 70, National Electrical Code, 2017, Table 310.15(B)(16), Table 310.15(B)(3)(a)
A single 30-hp, 460-V, 3-phase induction motor (continuous duty) has a Table 430.250 full-load current of 40 A. Under 430.22, what minimum branch-circuit conductor ampacity is required?
Answer: 50 A
430.6(A)(1) requires using the table full-load current (40 A from Table 430.250), and 430.22 requires branch-circuit conductors for a single continuous-duty motor to have an ampacity of at least 125% of that FLC: 40 × 1.25 = 50 A. Using the nameplate current or 100% of FLC undersizes the conductors.
Reference: NFPA 70, National Electrical Code, 2017, 430.6(A)(1), 430.22, Table 430.250
Conductors 4 AWG and larger make a straight pull through a pull box, entering and leaving through 2-1/2-in conduits. Under 314.28(A)(1), what is the minimum length of the box?
Answer: 20 in
314.28(A)(1) requires the length of a box for a straight pull to be at least 8 times the trade size of the largest raceway: 8 × 2.5 = 20 in. Angle and U pulls use 6 times the largest raceway plus the sum of the others on the same wall and row (314.28(A)(2)).
Reference: NFPA 70, National Electrical Code, 2017, 314.28(A)(1)
A recessed luminaire NOT identified as Type IC is installed in a ceiling. Under 410.116(A)(1) and (B), what clearances are required?
Answer: 1/2 in from combustible material (except at the support points) and 3 in from thermal insulation
410.116(A)(1) requires a recessed luminaire not identified for contact with insulation to be spaced at least 1/2 in from combustible materials, except at points of support and the finish trim. 410.116(B) requires thermal insulation to be kept at least 3 in from the enclosure, wiring compartment or ballast, and not above it in a way that traps heat. Type IC luminaires may contact insulation.
Reference: NFPA 70, National Electrical Code, 2017, 410.116(A)(1), 410.116(B)
A crane will work near an overhead power line rated 115 kV. Using Table A of 29 CFR 1926.1408, what is the minimum clearance that must be maintained?
Answer: 15 ft
Table A to 1926.1408 sets minimum clearance distances by voltage: up to 50 kV 10 ft; over 50 to 200 kV 15 ft; over 200 to 350 kV 20 ft; over 350 to 500 kV 25 ft; over 500 to 750 kV 35 ft; over 750 to 1,000 kV 45 ft. 115 kV falls in the over-50-to-200 kV row, so 15 ft.
Reference: 29 CFR Part 1926, 1926.1408, Table A
Under 29 CFR 1926.416(a)(1), an electrician may not work close enough to an electric power circuit to contact it in the course of work unless what?
Answer: The circuit is deenergized and grounded or guarded by effective insulation or other means
1926.416(a)(1) prohibits employers from permitting employees to work so close to any part of an electric power circuit that they could contact it, unless they are protected against shock by deenergizing the circuit and grounding it or by guarding it with effective insulation or other means. The employer must also ascertain the location of hidden circuits (1926.416(a)(3)).
Reference: 29 CFR Part 1926, 1926.416(a)(1)
Sources
- PSI: Nevada Contractors "C" Classification Candidate Information Bulletin (3/25/2026) (opens in a new tab)
- Nevada State Contractors Board: License examinations (opens in a new tab)
Questions last verified October 22, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.