Requirements at a glance
| Agency | Your Nebraska city licenses you (Omaha, Lincoln, Grand Island, Kearney, Columbus and others); IAPMO gives the exam |
|---|---|
| Experience | Set by your city (Nebraska has no state plumbing license) |
| Exam | 100 multiple-choice questions, 3 hours; pass mark not published |
| Books allowed | Original, bound Uniform Plumbing Code matching the exam's code year (no loose papers or notes) |
| Fees | IAPMO exam fee (not published), plus your city's license fees |
Plumbers applying to a Nebraska city that uses the IAPMO exam, such as Grand Island or Kearney, for a journeyman license. Nebraska has no state plumbing license, so your city sets the experience rules.
How to get licensed, step by step
Get your city's approval
Ask your city which exam it uses and what experience it requires. IAPMO will not let you test without approval.
IAPMO: Nebraska plumbing license testing (opens in a new tab)
Register with IAPMO
Register for the exam on IAPMO's online proctored FLEX platform. For Lincoln, email the city (pgenrich@lincoln.ne.gov) instead.
IAPMO: Nebraska plumbing license testing (opens in a new tab)
Take the exam
The exam is open book with your bound UPC. A code book from the wrong year is turned away.
IAPMO: Nebraska plumbing license testing (opens in a new tab)
Get licensed
Send your city your results and license fee.
IAPMO: Nebraska plumbing license testing (opens in a new tab)
How to prepare
- Nebraska has no state plumbing license: your city licenses you. Grand Island and Kearney test the 2021 UPC, Columbus tests the 2018 UPC with gas, and Lincoln runs its own 2018 UPC exam with amendments. Get your city's approval and confirm the code year before you buy a book.
- IAPMO only admits an original, bound UPC whose edition matches the exam's code year, with no loose papers or notes in it. Our questions follow the 2021 UPC.
- Drainage (Chapter 7) and vents (Chapter 9) are the largest areas, then water supply and distribution (Chapter 6). Tab the sizing tables.
- Vents (Chapter 9) and sanitary drainage (Chapter 7) are 20 questions each. Know the fixture-unit and pipe-sizing tables.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the UPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Uniform Plumbing Code (UPC), 2021 Edition, IAPMOEssential
Open book: an original bound copy. IAPMO requires the edition to match the exam's code year: 2021 for Grand Island and Kearney, 2018 for Columbus and Lincoln.
IAPMO store (opens in a new tab)Read free: 2021 UPC (IAPMO) (opens in a new tab)
Official reference list (as published by the testing agency)
- Uniform Plumbing Code (UPC), 2021 edition for the Grand Island and Kearney exams: an original, bound copy whose edition matches the exam's code year
What's on the exam
Official content outline from IAPMO (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Chapter 3: General Regulations | 5 | |
| Chapter 4: Plumbing Fixtures and Fixture Fittings | 8 | |
| Chapter 5: Water Heaters | 8 | |
| Chapter 6: Water Supply and Distribution | 10 | |
| Chapter 7: Sanitary Drainage | 20 | |
| Chapter 8: Indirect Wastes | 5 | |
| Chapter 9: Vents | 20 | |
| Chapter 10: Traps and Interceptors | 5 | |
| Chapter 11: Storm Drainage | 10 | |
| Chapter 12: Fuel Gas Piping | 9 |
Exam day details
- Administered by IAPMO for Nebraska cities (Grand Island, Kearney and others).
- Fee: Paid to IAPMO when you register (amount not published). Your city's license fees are separate.
- 100 multiple-choice questions in 3 hours (180 minutes).
- Open book: only an original, bound UPC (no photocopies) whose edition matches the exam's code year. Loose papers or notes in the book end the exam and are reported.
- Online proctored on IAPMO's FLEX platform. You need your city's approval before you register; IAPMO does not print the exam fee or pass mark.
- Nebraska has no state plumbing license. Cities such as Omaha, Lincoln, Grand Island, Kearney and Columbus license plumbers. Grand Island and Kearney use the 2021 UPC; Columbus tests the 2018 UPC with gas, and Lincoln runs its own 2018 UPC exam with amendments. Our questions follow the 2021 UPC.
Note: IAPMO does not publish the pass mark or fee, and Nebraska cities may amend the UPC.
Frequently asked questions
What's on the Nebraska journeyman plumber exam?
100 questions from the 2021 UPC: drainage (Chapter 7) and vents (Chapter 9) 20 each, water supply and distribution 10, general regulations 5, fixtures 8, water heaters 8, indirect wastes 5, traps and interceptors 5, storm drainage 10 and Chapter 12 9.
Which UPC edition does it use?
Grand Island and Kearney test the 2021 UPC. Columbus tests the 2018 UPC with gas, and Lincoln runs its own 2018 exam with amendments. Your code book must match the exam's year.
Free questions with answers
Show all 10 free questions and answers
A water piping system will be hydrostatically tested at 150 psi. Using the UPC rules for test gauges, what is the maximum pressure range the dial gauge may have?
Answer: 300 psi, which is twice the test pressure
Section 318.5 limits a test gauge to a pressure range not exceeding twice the test pressure: 2 x 150 = 300 psi. Because 150 psi is over 100 psi, Section 318.4 also requires graduations of 2 percent or less of the test pressure (2% x 150 = 3 psi). Ranges of 450 or 600 psi exceed the 2x limit; 225 psi is within it but is not the maximum.
Reference: 2021 Uniform Plumbing Code, Sections 318.4 and 318.5
A floor-mounted water closet is being roughed in beside a framed side wall, with another water closet to be installed next to it. What are the minimum UPC setting distances?
Answer: 15 inches from its center to the side wall and 30 inches center to center to the next water closet
Section 402.5 requires a water closet or bidet to be set no closer than 15 inches center to the side wall or obstruction and 30 inches center to center from a similar fixture, with at least 24 inches clear in front. The 12 inch and 24 inch figures are the urinal spacings.
Reference: 2021 Uniform Plumbing Code, Section 402.5
A 40,000 Btu/h water heater and a 60,000 Btu/h boiler share one small room. Using the standard method for indoor combustion air, what minimum room volume is required?
Answer: 5000 cubic feet
Section 506.2.1 requires 50 cubic feet per 1000 Btu/h, and the volumes for all appliances in the space are added. Total input = 40,000 + 60,000 = 100,000 Btu/h; 100 x 50 = 5000 cubic feet. Using only the heater gives 2000, and only the boiler gives 3000.
Reference: 2021 Uniform Plumbing Code, Sections 506.2 and 506.2.1
After allowing for friction and other pressure losses, what minimum residual water pressure must the UPC supply system deliver, unless a fixture needs more?
Answer: 15 psi
Section 608.1 says that where the main cannot provide a residual pressure of at least 15 psi after friction and other losses, a tank and pump or other means must be installed to provide it. Fixtures that need more than 15 psi must be given their required residual pressure.
Reference: 2021 Uniform Plumbing Code, Section 608.1
Which fitting is permitted where a horizontal drain connects into another horizontal drain?
Answer: A 45 degree wye branch
Section 706.3 permits 45 degree wye branches, combination wye and one-eighth bend branches, or equivalent-sweep fittings for horizontal-to-horizontal connections. Sanitary tees are listed in Section 706.2 only for horizontal drains entering a vertical stack.
Reference: 2021 Uniform Plumbing Code, Section 706.3
An indirect waste pipe serves a food preparation sink in a restaurant. What size and length limits apply under Section 801.3.1?
Answer: Not smaller than the unit's drain, at least 1 inch, and no longer than 15 feet developed length
Section 801.3.1 requires indirect waste pipes in food and beverage establishments (except refrigeration coils and ice-making machines) to be no smaller than the unit's drain, in no case smaller than 1 inch, and not longer than 15 feet developed length. Ice machine wastes may be 3/4 inch if the drain on the unit is that size.
Reference: 2021 Uniform Plumbing Code, Section 801.3.1
Copper tube is marked with color codes under the UPC. Which color identifies Type DWV tube?
Answer: Yellow
Section 903.2.3 requires copper tubing to be marked with these colors: Type K green, Type L blue, Type M red and Type DWV yellow, in addition to the incised marking.
Reference: 2021 Uniform Plumbing Code, Section 903.2.3
What liquid seal depth must each fixture trap have, unless the Authority Having Jurisdiction requires deeper?
Answer: At least 2 inches and not more than 4 inches
Section 1005.1 requires each fixture trap to have a liquid seal of not less than 2 inches and not more than 4 inches, except where the Authority Having Jurisdiction finds a deeper seal necessary. Sand interceptors have a separate 6 inch seal requirement.
Reference: 2021 Uniform Plumbing Code, Section 1005.1
A vertical leader drains a 5000 square foot roof in an area with a rainfall rate of 4 inches per hour. Using Table 1103.1, what is the smallest leader size?
Answer: 5 inches
At 4 in/h, Table 1103.1 allows 2200 sq ft for a 3 inch leader, 4600 sq ft for 4 inch, 8650 sq ft for 5 inch and 13,500 sq ft for 6 inch. A 4 inch leader (4600) is too small for 5000 sq ft, so 5 inches is the smallest that works.
Reference: 2021 Uniform Plumbing Code, Table 1103.1
A new gas piping system carrying 7 inches water column pressure and not welded is tested with air. What test pressure and hold time does Section 1213.3 require?
Answer: 10 psi gauge, held at least 15 minutes with no perceptible drop
Section 1213.3 requires gas piping to stand not less than 10 psi gauge, held for a time satisfactory to the Authority Having Jurisdiction but never less than 15 minutes with no perceptible pressure drop. The 60 psi and 30 minute figures apply to welded piping or piping above 14 inches water column.
Reference: 2021 Uniform Plumbing Code, Section 1213.3