Requirements at a glance
| Agency | Mississippi State Board of Contractors (MSBOC); exams by PSI |
|---|---|
| License | Residential license (work over $10,000) |
| Exams | 80 questions, 4 hours, 70%, plus the Law and Business Management exam |
| Books allowed | 2021 IPC, 2018 Fuel Gas Code and 2021 IRC |
| Fees | $120 per PSI exam portion (nonrefundable), plus the MSBOC application fee ($50 residential; $100 for each added classification) |
Qualifying individuals for a Mississippi residential plumbing license, which is part of the residential mechanical license with residential HVAC.
Official links
How to get licensed, step by step
Apply to the MSBOC
Send the application and fee to the Board. The firm names a qualifying individual who takes the exams.
MSBOC: contractor licenses (opens in a new tab)Mississippi State Board of Contractors (MSBOC) (opens in a new tab)
Schedule the Law and Business exam and the residential plumbing exam with PSI
After the Board approves you it notifies PSI. Book both exams ($120 per portion). You have 6 months from eligibility to pass, with unlimited retests in that window.
Schedule with PSI (Mississippi contractors) (opens in a new tab)PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)
Pass both exams at 70%
Both exams are open book and need 70% to pass.
PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)
Get licensed
The Board reviews applications weekly and issues the license in about 5 working days after approval. Licenses renew annually.
Mississippi State Board of Contractors (MSBOC) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's list: the 2020 NEC for electrical, the 2021 IPC, IMC and IFGC for commercial plumbing and mechanical, and the 2018 Fuel Gas Code with the 2021 IRC on the residential lists. Code questions use only the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight, underline and index them, but you can't write in them or add loose papers; sticky notes are removed.
- Mississippi licenses contractor firms, not individual tradespeople. These are the exams the firm's qualifying individual takes; journeyman and master cards are local.
- Drain, waste and vent and sewers (17) and general plumbing knowledge and regulations (15) are 32 of the 80 questions.
- The fuel gas sections (fuel gas, LP gas, fuel oil and piping) use the 2018 IFGC, not the 2021 edition.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IPC and the 2018 IFGC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 International Plumbing Code (IPC)Essential
Allowed in the exam room. The core of both plumbing exams and the plumbing share of the mechanical exam.
2018 International Fuel Gas Code (IFGC)Essential
PSI lists the 2018 edition for the residential plumbing and residential HVAC exams.
2021 International Residential Code (IRC)
Allowed in the residential electrician and residential plumbing exam rooms.
Official reference list (as published by the testing agency)
- 2021 International Plumbing Code (IPC)
- 2018 International Fuel Gas Code (IFGC)
- 2021 International Residential Code (IRC)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Plumbing Knowledge and Regulations | 15 | |
| Piping Valves and Controls | 6 | |
| Fixtures and Equipment | 4 | |
| Water Supply | 4 | |
| Drain Waste and Vent and Sewers | 17 | |
| Isometric Analysis | 9 | |
| Safety | 4 | |
| Specialty Applications | 6 | |
| Fuel Gas | 5 | |
| LP Gas | 3 | |
| Fuel Oil | 2 | |
| Piping | 5 |
Exam day details
- Administered by PSI Services for the Mississippi State Board of Contractors (MSBOC).
- Fee: $120 per exam portion to PSI, nonrefundable. MSBOC application and license fees are separate.
- 80 scored questions in 4 hours; 56 correct (70%) to pass. PSI adds about 10% unscored experimental items.
- Open book: bring only the exact editions on PSI's list for this exam. You may highlight, underline and index them with permanent tabs, but not write in them; sticky notes are removed. A silent, non-programmable calculator is allowed.
- After the MSBOC approves your application it notifies PSI, and you have 6 months from eligibility to pass; retests within that window are unlimited.
- Every Mississippi contractor license needs the Law and Business Management exam plus the trade exam for the classification.
- State-specific code rules override the national code, and code questions use only the listed edition.
Frequently asked questions
What's on the Mississippi Residential Plumbing Exam?
80 scored questions: Drain Waste and Vent and Sewers 17, general plumbing knowledge and regulations 15, isometric analysis 9, piping valves and controls 6, specialty applications 6, fuel gas 5, piping 5, fixtures and equipment 4, water supply 4, safety 4, lp gas 3, fuel oil 2.
Which books can I bring to the Mississippi Residential Plumbing Exam?
The 2021 IPC, the 2018 International Fuel Gas Code and the 2021 IRC.
Does Mississippi license individual tradespeople at the state level?
No. The MSBOC licenses contractor firms, and each firm names a qualifying individual who takes these exams. Journeyman and master cards are issued locally by cities.
Free questions with answers
Show all 10 free questions and answers
A new gas range is being connected in a kitchen of a single-family house. Where must the appliance shutoff valve be located if it is installed in the same room as the range?
Answer: Within 6 feet of the range, with access, upstream of the connector
Section 409.5.1 requires the shutoff valve in the same room as the appliance, within 6 feet of it, accessible, and installed upstream of the union, connector or quick-disconnect it serves. A valve behind a movable range counts as accessible. The 50-foot distance applies only to manifold valves under 409.5.3.
Reference: 2018 International Fuel Gas Code, Section 409.5.1
A horizontal run of 1-inch steel gas pipe is being supported in a basement. By the Fuel Gas Code support table, what is the maximum interval between supports?
Answer: 8 feet
Table 415.1 gives 6 feet for 1/2-inch steel pipe, 8 feet for 3/4-inch or 1-inch, and 10 feet for 1 1/4-inch and larger horizontal pipe. Vertical pipe 1 1/4 inch and larger is supported at every floor level.
Reference: 2018 International Fuel Gas Code, Table 415.1
Two houses are built on the same lot, and a public sewer runs in the street in front of them. Under the Plumbing Code, how may the houses connect to the sewer?
Answer: Both may connect to one common building sewer that joins the public sewer
Section 701.3 requires a separate sewer connection for a building abutting a street with a public sewer, but states that multiple buildings on the same lot are not prohibited from connecting to a common building sewer that connects to the public sewer.
Reference: 2021 International Plumbing Code, Section 701.3
What does Section 305.5 require at the point where a vent pipe passes through a roof?
Answer: A watertight joint made with an approved flashing material
Section 305.5 requires joints at the roof and around vent pipes to be watertight using lead, copper, galvanized steel, aluminum, plastic or other approved flashing material. Exterior wall openings must also be made watertight.
Reference: 2021 International Plumbing Code, Section 305.5
A homeowner wants the water heater's thermostat alone to serve as the temperature limiting means for delivery temperature at fixtures. Under Section 607.1.1, when is this permitted?
Answer: Where the water heater complies with ASSE 1082 or ASSE 1085
Section 607.1.1 allows a water heater thermostat to serve as the temperature limiting means for maximum hot or tempered water delivery temperature only where the water heater complies with ASSE 1082 or ASSE 1085. Otherwise a separate tempering device is needed.
Reference: 2021 International Plumbing Code, Section 607.1.1
A storage water heater relief valve is being chosen. Which temperature and pressure settings meet Section 504.5?
Answer: Not over 210 degrees F, and a pressure not over the tank rating or 150 psi, whichever is less
Section 504.5 requires relief valves labeled by an approved agency with a temperature setting of not more than 210 degrees F and a pressure setting not exceeding the tank or water heater manufacturer's rated working pressure or 150 psi, whichever is less.
Reference: 2021 International Plumbing Code, Section 504.5
A water service line is being routed through a lot with a septic system. Which location is prohibited for a potable water service pipe under Section 603.2.1?
Answer: In, under or above a septic tank or its drainage field
Section 603.2.1 prohibits potable water service pipes in, under or above cesspools, septic tanks, septic tank drainage fields or seepage pits. Where soil or groundwater contamination is suspected, analysis is required under Section 605.1.
Reference: 2021 International Plumbing Code, Section 603.2.1
Who must inspect excavations, adjacent areas and protective systems under 29 CFR 1926.651(k)(1), and how often?
Answer: A competent person, daily, before work starts and as needed
Section 1926.651(k)(1) requires daily inspections by a competent person before the start of work and as needed during the shift, and also after every rainstorm or other hazard-increasing occurrence, where employee exposure can be reasonably anticipated.
Reference: 29 CFR Part 1926, Subpart P, 29 CFR 1926.651(k)(1)
A master bath has a private water closet (1.6 gpf), two lavatories, a bathtub, and a separate shower with a total showerhead flow of 8.0 gpm. Counting each fixture individually with Table 709.1 (not using the bathroom group value), what is the total drainage fixture unit load of the fixtures listed?
Answer: 10 dfu
Table 709.1 gives a private 1.6 gpf water closet 3 dfu, each lavatory 1, a bathtub 2, and a shower of more than 5.7 up to 12.3 gpm 3 dfu. Total = 3 + 1 + 1 + 2 + 3 = 10 dfu. 9 dfu uses the 2-dfu value for a shower of 5.7 gpm or less (or a 5-dfu bathroom group plus the extra lavatory and shower), and 11 dfu uses 4 dfu for the water closet.
Reference: 2021 International Plumbing Code, Table 709.1
A sump pump in a residential basement pit is being set up. How high may the effluent be allowed to rise, per Section 712.3.4?
Answer: Not within 2 inches of the invert of the gravity drain inlet
Section 712.3.4 requires the effluent level control to be adjusted and maintained so the effluent never rises to within 2 inches of the invert of the gravity drain inlet into the sump.
Reference: 2021 International Plumbing Code, Section 712.3.4