Question 1 of 10Hangers and Supports

A plumber is hanging horizontal PVC drain pipe in a ceiling space. Using Table 308.5, what is the maximum horizontal hanger spacing?

Requirements at a glance

AgencyMississippi State Board of Contractors (MSBOC); exams by PSI
LicenseCommercial Certificate of Responsibility (projects of $50,000 or more)
Exams70 questions, 3 hours, 70%, plus the Law and Business Management exam
Books allowed2021 IPC, 29 CFR 1926 and Mathematics for Plumbers and Pipefitters, 8th Edition
Fees$120 per PSI exam portion (nonrefundable), plus the MSBOC application fee ($400 commercial; $100 for each added classification)

Qualifying individuals for a Mississippi commercial plumbing contractor classification. The exam does not cover fuel gas or boilers.

How to get licensed, step by step

  1. Apply to the MSBOC

    Send the application, fee and a CPA-reviewed financial statement to the Board. The firm names a qualifying individual who takes the exams.

    MSBOC: contractor licenses (opens in a new tab)Mississippi State Board of Contractors (MSBOC) (opens in a new tab)

  2. Schedule the Law and Business exam and the plumbing exam with PSI

    After the Board approves you it notifies PSI. Book both exams ($120 per portion). You have 6 months from eligibility to pass, with unlimited retests in that window.

    Schedule with PSI (Mississippi contractors) (opens in a new tab)PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)

  3. Pass both exams at 70%

    Both exams are open book and need 70% to pass.

    PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)

  4. Get licensed

    The Board reviews applications weekly and issues the license in about 5 working days after approval. Licenses renew annually.

    Mississippi State Board of Contractors (MSBOC) (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's list: the 2020 NEC for electrical, the 2021 IPC, IMC and IFGC for commercial plumbing and mechanical, and the 2018 Fuel Gas Code with the 2021 IRC on the residential lists. Code questions use only the listed edition.
  • Tab your books before exam day with permanent tabs only. You can highlight, underline and index them, but you can't write in them or add loose papers; sticky notes are removed.
  • Mississippi licenses contractor firms, not individual tradespeople. These are the exams the firm's qualifying individual takes; journeyman and master cards are local.
  • Drain, waste and vent (15) and isometric analysis (12) are 27 of the 70 questions. Tab the IPC Chapter 7 and 9 sizing tables and practice fixture-unit totals from a riser diagram.
  • The plumbing exam does not cover fuel gas or boilers; those are on the mechanical exam.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2021 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2021 International Plumbing Code (IPC)Essential

    Allowed in the exam room. The core of both plumbing exams and the plumbing share of the mechanical exam.

    ICC store (opens in a new tab)

  • Mathematics for Plumbers and Pipefitters, 8th Edition (Cengage)

    Allowed in the plumbing exam room. Offsets, grade, volume and pipe-sizing math.

    Cengage (opens in a new tab)

Official reference list (as published by the testing agency)
  • 2021 International Plumbing Code (IPC)
  • 29 CFR 1926 (OSHA construction standards)
  • Mathematics for Plumbers and Pipefitters, 8th Edition (2013)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Plumbing Regulations4
Safety4
Cleanouts4
Fixtures and Equipment5
Water Heaters2
Piping valves controls3
Water Supply6
Hangers and Supports3
Drain Waste and Vent15
Backflow3
Traps and Interceptors4
Developed length2
Isometric Analysis12
Joints and Connections3

Exam day details

  • Administered by PSI Services for the Mississippi State Board of Contractors (MSBOC).
  • Fee: $120 per exam portion to PSI, nonrefundable. MSBOC application and license fees are separate.
  • 70 scored questions in 3 hours; 49 correct (70%) to pass. PSI adds about 10% unscored experimental items.
  • Open book: bring only the exact editions on PSI's list for this exam. You may highlight, underline and index them with permanent tabs, but not write in them; sticky notes are removed. A silent, non-programmable calculator is allowed.
  • After the MSBOC approves your application it notifies PSI, and you have 6 months from eligibility to pass; retests within that window are unlimited.
  • Every Mississippi contractor license needs the Law and Business Management exam plus the trade exam for the classification.
  • State-specific code rules override the national code, and code questions use only the listed edition.

Frequently asked questions

What's on the Mississippi Plumbing Exam?

70 scored questions: Drain Waste and Vent 15, isometric analysis 12, water supply 6, fixtures and equipment 5, general plumbing regulations 4, safety 4, cleanouts 4, traps and interceptors 4, piping valves controls 3, hangers and supports 3, backflow 3, joints and connections 3, water heaters 2, developed length 2.

Which books can I bring to the Mississippi Plumbing Exam?

The 2021 IPC, 29 CFR 1926 and Mathematics for Plumbers and Pipefitters, 8th Edition (2013).

Does Mississippi license individual tradespeople at the state level?

No. The MSBOC licenses contractor firms, and each firm names a qualifying individual who takes these exams. Journeyman and master cards are issued locally by cities.

Free questions with answers

Show all 10 free questions and answers
  1. A plumber is hanging horizontal PVC drain pipe in a ceiling space. Using Table 308.5, what is the maximum horizontal hanger spacing?

    Answer: 4 feet

    Table 308.5 lists PVC pipe at 4 feet maximum horizontal spacing and 10 feet vertical (with a mid-story guide per the footnote). 5 feet is the cast-iron figure and 6 feet is copper tubing 1 1/4 inch and smaller.

    Reference: 2021 International Plumbing Code, Table 308.5

  2. A 4-inch horizontal drain changes direction 90 degrees at an offset, then changes direction 90 degrees again 25 feet of developed length later. How many cleanouts does the code require for these two changes?

    Answer: One cleanout at the first change serves both

    Section 708.1.4 requires a cleanout at a horizontal change of direction greater than 45 degrees. Where more than one such change occurs within 40 feet of developed length, the first cleanout serves all of them. Two turns 25 feet apart therefore need one cleanout, at the first change.

    Reference: 2021 International Plumbing Code, Section 708.1.4

  3. A site-built shower floor is lined with a membrane that is to be turned up at the walls. What is the minimum turn-up above the finished threshold, and the lowest point where the liner may be nailed or perforated?

    Answer: 2 inches above the threshold; nothing within 1 inch of the threshold

    Section 421.5.2 requires the liner to turn up at least 2 inches above the finished threshold and prohibits nailing or perforating it less than 1 inch above the threshold. The liner is pitched 1/4 unit vertical per 12 units horizontal toward the drain.

    Reference: 2021 International Plumbing Code, Section 421.5.2

  4. A valve serving a fixture is located away from that fixture in a mechanical room. What does the code require?

    Answer: The valve must be identified to show the fixture or appliance it serves

    Section 606.4 requires service and hose bibb valves to be identified, and valves not adjacent to the fixture or appliance to be identified as to what they serve. Section 606.3 separately requires access to all full-open and shutoff valves.

    Reference: 2021 International Plumbing Code, Section 606.4

  5. Table 604.3 requires what capacity at the supply outlet of a blow-out water closet with a flushometer valve?

    Answer: 25 gpm at 45 psi flow pressure

    Table 604.3 lists the blow-out flushometer closet at 25 gpm and 45 psi. 12 gpm at 25 psi is the flushometer urinal, and 3 gpm at 20 psi is a close-coupled tank closet.

    Reference: 2021 International Plumbing Code, Table 604.3

  6. A 4-inch horizontal waste line carries kitchen waste to a grease interceptor. What minimum slope applies upstream of the interceptor?

    Answer: 1/4 inch per foot

    Section 704.1 says that where the drainage piping is upstream of a grease interceptor, the slope must be not less than 1/4 inch per foot (2 percent), instead of the 1/8 inch per foot normally allowed for 4-inch pipe in Table 704.1.

    Reference: 2021 International Plumbing Code, Section 704.1

  7. Copper tube passes through a steel stud wall. To keep the metal from direct contact with the steel, what minimum sheathing does Section 305.1 require, if sheathing is used?

    Answer: Plastic sheathing at least 8 mil (0.008 inch) thick

    Section 305.1 prohibits direct contact between metallic piping (other than cast iron, ductile iron and galvanized steel) and steel framing, concrete or masonry. Where sheathing is used it must be plastic not less than 0.008 inch (8 mil) thick.

    Reference: 2021 International Plumbing Code, Section 305.1

  8. A lavatory trap is being set. What is the maximum vertical distance from the fixture outlet to the trap weir, and the maximum horizontal distance from the fixture outlet centerline to the trap inlet?

    Answer: 24 inches vertical and 30 inches horizontal

    Section 1002.1 limits the vertical distance from the fixture outlet to the trap weir to 24 inches and the horizontal distance, centerline of outlet to centerline of trap inlet, to 30 inches. A fixture may not be double trapped.

    Reference: 2021 International Plumbing Code, Section 1002.1

  9. At what trench depth does OSHA require a stairway, ladder, ramp or other safe means of egress within 25 feet of lateral travel for workers?

    Answer: 4 feet or more

    29 CFR 1926.651(c)(2) requires a safe means of egress in trench excavations 4 feet or more deep, located so that no more than 25 feet of lateral travel is needed. The 5-foot depth is the threshold for protective systems in 1926.652.

    Reference: 29 CFR 1926 (OSHA Construction Standards), 29 CFR 1926.651(c)(2)

  10. A 4-inch horizontal drain runs 60 feet at the minimum slope of 1/8 inch per foot. How much total fall occurs over the run?

    Answer: 7 1/2 inches

    Fall = 60 ft x 1/8 inch per foot = 7.5 inches. Using 1/4 inch per foot would give 15 inches, and 1/16 inch per foot would give 3 3/4 inches.

    Reference: 2021 International Plumbing Code, Table 704.1