Mississippi licensing exam

Mississippi Residential Electrician Exam: Practice Test & Licensing Guide

The PSI trade exam for Mississippi residential electrical: 60 questions on the 2020 NEC and 2021 IRC for dwellings. Open book, 70% to pass.

Questions
60
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Electrical Knowledge

A 120-volt portable space heater element measures 9.6 ohms when hot. Using Ohm's law, what current does the heater draw?

Requirements at a glance

AgencyMississippi State Board of Contractors (MSBOC); exams by PSI
LicenseResidential license (work over $10,000)
Exams60 questions, 3 hours, 70%, plus the Law and Business Management exam
Books allowed2020 NEC, 2021 IRC and Ugly's Electrical References (2017)
Fees$120 per PSI exam portion (nonrefundable), plus the MSBOC application fee ($50 residential; $100 for each added classification)

Qualifying individuals for a Mississippi residential electrical license from the MSBOC (residential work over $10,000).

How to get licensed, step by step

  1. Apply to the MSBOC

    Send the application and fee to the Board. The firm names a qualifying individual who takes the exams.

    MSBOC: contractor licenses (opens in a new tab)Mississippi State Board of Contractors (MSBOC) (opens in a new tab)

  2. Schedule the Law and Business exam and the residential electrician exam with PSI

    After the Board approves you it notifies PSI. Book both exams ($120 per portion). You have 6 months from eligibility to pass, with unlimited retests in that window.

    Schedule with PSI (Mississippi contractors) (opens in a new tab)PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)

  3. Pass both exams at 70%

    Both exams are open book and need 70% to pass.

    PSI: Mississippi contractor exam bulletin and outlines (opens in a new tab)

  4. Get licensed

    The Board reviews applications weekly and issues the license in about 5 working days after approval. Licenses renew annually.

    Mississippi State Board of Contractors (MSBOC) (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's list: the 2020 NEC for electrical, the 2021 IPC, IMC and IFGC for commercial plumbing and mechanical, and the 2018 Fuel Gas Code with the 2021 IRC on the residential lists. Code questions use only the listed edition.
  • Tab your books before exam day with permanent tabs only. You can highlight, underline and index them, but you can't write in them or add loose papers; sticky notes are removed.
  • Mississippi licenses contractor firms, not individual tradespeople. These are the exams the firm's qualifying individual takes; journeyman and master cards are local.
  • General electrical knowledge (13) and services, feeders and branch circuits (15) are nearly half of the exam: Ohm's law, load calculations and Articles 210, 220 and 230.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC), 2020 Edition
  • 2021 International Residential Code (IRC)
  • Ugly's Electrical References, 2017 Edition

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Electrical Knowledge13
Services Feeders and Branch Circuits15
Overcurrent Protection5
Grounding and Bonding6
Conductors and Cables5
Raceways and Boxes4
Lighting4
Specialty4
Safety4

Exam day details

  • Administered by PSI Services for the Mississippi State Board of Contractors (MSBOC).
  • Fee: $120 per exam portion to PSI, nonrefundable. MSBOC application and license fees are separate.
  • 60 scored questions in 3 hours; 42 correct (70%) to pass. PSI adds about 10% unscored experimental items.
  • Open book: bring only the exact editions on PSI's list for this exam. You may highlight, underline and index them with permanent tabs, but not write in them; sticky notes are removed. A silent, non-programmable calculator is allowed.
  • After the MSBOC approves your application it notifies PSI, and you have 6 months from eligibility to pass; retests within that window are unlimited.
  • Every Mississippi contractor license needs the Law and Business Management exam plus the trade exam for the classification.
  • State-specific code rules override the national code, and code questions use only the listed edition.

Frequently asked questions

What's on the Mississippi Residential Electrician Exam?

60 scored questions: Services Feeders and Branch Circuits 15, general electrical knowledge 13, grounding and bonding 6, overcurrent protection 5, conductors and cables 5, raceways and boxes 4, lighting 4, specialty 4, safety 4.

Which books can I bring to the Mississippi Residential Electrician Exam?

The 2020 NEC, the 2021 IRC and Ugly's Electrical References (2017).

Does Mississippi license individual tradespeople at the state level?

No. The MSBOC licenses contractor firms, and each firm names a qualifying individual who takes these exams. Journeyman and master cards are issued locally by cities.

Free questions with answers

Show all 10 free questions and answers
  1. A 120-volt portable space heater element measures 9.6 ohms when hot. Using Ohm's law, what current does the heater draw?

    Answer: 12.5 amperes

    Ohm's law gives I = E / R = 120 / 9.6 = 12.5 A. 9.6 / 120 = 0.08 A inverts the formula, 120 x 9.6 = 1,152 multiplies instead of divides, and 120 - 9.6 = 110.4 subtracts, which has no physical meaning.

    Reference: General electrical theory, Ohm's law, I = E / R

  2. For a new dwelling, what does 210.11(C)(2) require for the laundry area?

    Answer: At least one additional 20-ampere branch circuit with no other outlets

    Section 210.11(C)(2) requires at least one additional 20-ampere branch circuit to supply the laundry receptacle outlet(s), and it may have no other outlets. It is separate from the two small-appliance circuits, and it must be 20 amperes, not 15 or 30.

    Reference: NFPA 70, National Electrical Code, 2020 (rule identical in 2020-2026), 210.11(C)(2)

  3. A new dwelling has one bathroom with a basin, toilet and tub. Under 210.11(C)(3), what must be provided for the bathroom receptacle outlet?

    Answer: At least one 20-ampere branch circuit with no outlets outside the bathrooms it serves

    Section 210.11(C)(3) requires at least one 20-ampere branch circuit that supplies bathroom receptacle outlets and no other outlets (the circuit may serve only receptacles in bathrooms unless it serves a single bathroom, in which case other outlets in that bathroom are allowed). Sharing with halls, laundry or kitchen circuits is not permitted.

    Reference: NFPA 70, National Electrical Code, 2020 (rule identical in 2020-2026), 210.11(C)(3)

  4. A 4 AWG THWN copper feeder (85 A at 75 degrees C) supplies a subpanel with an 82-A load that is not a multioutlet receptacle branch circuit. Terminations are rated 75 degrees C. What is the largest standard breaker permitted by 240.4(B)?

    Answer: 90 amperes

    Section 240.4(B) permits the next standard size above the conductor ampacity when the circuit is not a multioutlet receptacle circuit, the ampacity does not match a standard rating, and the next size does not exceed 800 A. The next standard size above 85 A is 90 A (240.6(A)). 85 A is not a standard rating, 100 A is the following size, and 80 A is the standard size below the ampacity, which would be permitted but is not the largest.

    Reference: NFPA 70, National Electrical Code, 2020 (rule identical in 2020-2026), 240.4(B); 240.6(A)

  5. A large house has 250 kcmil copper service-entrance conductors. Its only grounding electrode conductor connects to the footing's concrete-encased electrode (Ufer) and goes to no other electrode. How large must that copper conductor be, at minimum?

    Answer: 4 AWG copper

    Table 250.66 would give 2 AWG copper for 250 kcmil copper service conductors, but 250.66(B) says a conductor that runs only to a concrete-encased electrode is not required to be larger than 4 AWG copper. 6 AWG is the cap for rod, pipe or plate electrodes under 250.66(A), and 1/0 is the table row for over 350 through 600 kcmil.

    Reference: NFPA 70, National Electrical Code, 2020 (rule identical in 2020-2026), 250.66(B); Table 250.66

  6. A 6 AWG THWN copper conductor terminates on a 75-degree C rated lug in a 100-ampere service panel. Using Table 310.16, what is its ampacity?

    Answer: 65 amperes

    The 75 degrees C column of Table 310.16 gives 65 A for 6 AWG copper. 55 A is the 60 degrees C value and 75 A the 90 degrees C value; 85 A is the 4 AWG, 75 degrees C value.

    Reference: NFPA 70, National Electrical Code, 2020 (rule identical in 2020-2026), Table 310.16

  7. A single-gang switch box contains two 12-2 NM cables with ground (four insulated 12 AWG conductors, two bare grounds), internal cable clamps and one single-pole switch. Counting per 314.16(B) at 2.25 cubic inches per 12 AWG conductor, which is the smallest standard metal device box, using Table 314.16(A)?

    Answer: 3 x 2 x 3-1/2 in. (18.0 cubic inches)

    Count: four insulated conductors = 4; all equipment grounds together = 1; internal clamps = 1; one yoke (switch) = 2. Total = 8 allowances x 2.25 = 18.0 cubic inches. Only the 3 x 2 x 3-1/2 in. box (18.0) meets that volume; the others are too small.

    Reference: NFPA 70, National Electrical Code, 2020 (rule identical in 2020-2026), 314.16(B); Table 314.16(A)

  8. A surface-mounted incandescent luminaire with a completely enclosed lamp is installed in a dwelling clothes closet. What is the minimum clearance from the nearest point of storage space, per 410.16?

    Answer: 12 inches

    Section 410.16(C) requires 12 in between a surface-mounted incandescent luminaire with a completely enclosed light source and the nearest point of the storage space; 6 in applies to surface fluorescent, recessed incandescent with a completely enclosed lamp, and recessed fluorescent types. 3 in is not a value for this location and 18 in is more than required.

    Reference: NFPA 70, National Electrical Code, 2020 (rule identical in 2020-2026), 410.16(C)

  9. A residential electric vehicle charger (EVSE) draws a maximum of 40 amperes and is treated as a continuous load. What is the minimum rating of the overcurrent device protecting its branch circuit?

    Answer: 50 amperes

    EVSE is a continuous load, so the minimum rating is 40 x 1.25 = 50 A (625.41 and 210.20(A)), which is a standard size under 240.6(A). A 40 A device is loaded to 100 percent continuously; 45 A is not a standard rating for this need; 60 A is oversized.

    Reference: NFPA 70, National Electrical Code, 2020 (rule identical in 2020-2026), 625.41; 210.20(A)

  10. In a new dwelling with several required smoke alarms, how must they be connected under 2021 IRC R314.4?

    Answer: Interconnected so that one alarm sounds all of them

    Section R314.4 requires smoke alarms in an individual dwelling unit to be interconnected so that actuation of one activates all, using wired or listed wireless interconnection. Separate sounding alarms do not provide the alert throughout the house.

    Reference: 2021 International Residential Code, R314.4

Sources

Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.