Michigan licensing exam

Michigan Master Plumber Exam: Practice Test & Licensing Guide

The PSI exam for Michigan's master plumber license: 130 questions on drainage, venting, fixtures, water distribution, backflow, storm drains, special waste, testing, inspections and the Skilled Trades Regulation Act, plus a material take-off. Open book.

Questions
130
Time limit
3 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Venting

A vent system must be designed so that the seal of a fixture trap is not subjected to a pressure differential greater than what amount?

Requirements at a glance

AgencyMichigan LARA, Bureau of Construction Codes; exam by PSI
Exam130 questions, 3 hours, 75% to pass, with a material take-off of back-to-back restrooms
Books allowed2021 Michigan Plumbing Code (chapter tabs only); PA 230 and PA 407 appear on screen
Fees$100 to PSI per attempt, plus LARA application and license fees
ExperienceAge 18 or older, a Michigan journey plumber license and 4,000 hours as a journey plumber over at least the 2 years before you apply (MCL 339.6113)

Plumbers applying to LARA for a Michigan master plumber license, which lets you run a plumbing business and pull permits as a master.

How to get licensed, step by step

  1. Apply to LARA

    Submit your master plumber application. LARA approves you before you can pay for the exam.

    Michigan LARA: Bureau of Construction Codes (opens in a new tab)

  2. Schedule with PSI

    Choose a test site or, since February 11, 2026, online with a remote proctor. Retests are unlimited at $100 each.

    Schedule with PSI (Michigan plumbing) (opens in a new tab)PSI: Michigan plumbing candidate bulletin (opens in a new tab)

  3. Prepare the take-off

    You list fittings, size vents and drains and identify venting methods for back-to-back restrooms, using the code book.

    PSI: Michigan plumbing candidate bulletin (opens in a new tab)

How to prepare

  • Bring only what the bulletin allows. Michigan reference books must be bound and unmarked: no highlighting, underlining or loose papers.
  • Michigan's codes are the 2021 Michigan Plumbing Code and Mechanical Code (the 2021 IPC and IMC with Michigan amendments) and the 2015 Michigan Residential Code. Study the Michigan text, not the model code.
  • Drainage (about a fifth) and venting are the biggest sections; tab by chapter and practice the sizing tables.
  • Read the Skilled Trades Regulation Act, 2016 PA 407, which is on screen during the test and is a named topic.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the Michigan Plumbing Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • 2021 Michigan Plumbing Code book (chapter tabs only)
  • State Construction Code Act, 1972 PA 230 (shown on screen; you can't bring it)
  • Skilled Trades Regulation Act, 2016 PA 407 (shown on screen; you can't bring it)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Drainage Systems20
General Knowledge10
Fixtures15
Water Distribution15
Backflow Protection10
Storm Drains10
Special Waste5
Testing8
Inspections7
Venting20
Skilled Trades Regulation Act10

Exam day details

  • Administered by PSI Services for the Michigan Department of Licensing and Regulatory Affairs (LARA), Bureau of Construction Codes.
  • Fee: $100 to PSI per attempt, non-refundable and valid for one year. LARA application and license fees are separate.
  • 130 questions in 3 hours; 75% to pass.
  • The bulletin lists topics but no per-topic weights. Our topic weights are an estimate that adds up to 130.
  • The exam includes a material take-off practical: from a drawing of back-to-back restrooms you list the fittings, size the vents and drains and identify venting methods using the code book.
  • Reference books must be bound and appear exactly as published: no highlighting, underlining, marking or loose papers, and only chapter tabs are allowed on the plumbing code book.
  • If you fail you may retest an unlimited number of times, paying the exam fee for each attempt. Since February 11, 2026 the master plumber exam can also be taken online with a remote proctor.
  • The Department (LARA BCC) must approve your application first. It sends a notification letter with instructions to pay and schedule with PSI; only the State decides eligibility.
  • PSI may add up to ten unscored experimental questions; they are not counted in your score and don't take time from the exam.
  • Cancel or reschedule at least 2 days before the appointment to keep your fee; late cancellations and no-shows forfeit it.

Frequently asked questions

What's on the Michigan master plumber exam?

130 questions on drainage systems, general knowledge, fixtures, water distribution, backflow protection, storm drains, special waste, testing, inspections, venting and the Skilled Trades Regulation Act (2016 PA 407), plus a material take-off of back-to-back restrooms.

Can I take the Michigan master plumber exam online?

Yes. Since February 11, 2026 PSI offers the master plumber exam with a remote proctor as well as at a test site.

Do I bring 1972 PA 230 and 2016 PA 407?

No. Both laws are displayed on screen. You bring only the 2021 Michigan Plumbing Code with chapter tabs.

Free questions with answers

Show all 10 free questions and answers
  1. A vent system must be designed so that the seal of a fixture trap is not subjected to a pressure differential greater than what amount?

    Answer: 1 inch of water column

    Section 901.2 requires a vent system that admits or emits air so trap seals are never exposed to more than 1 inch of water column (249 Pa) of pressure difference. The other values are not code limits.

    Reference: 2021 Michigan Plumbing Code, 901.2

  2. Which of the following is NOT considered a reduction in pipe size in the direction of flow under Section 704.2?

    Answer: A 4-inch by 3-inch water closet flange

    Section 704.2 prohibits reducing drainage pipe size in the direction of flow but lists exceptions: a 4 x 3 inch water closet flange, a closet bend with a 4-inch inlet and 3-inch outlet with the 4-inch leg upright, and an offset closet flange.

    Reference: 2021 Michigan Plumbing Code, 704.2

  3. Two water closets are installed side by side with no partition between them. What is the minimum center-to-center spacing?

    Answer: 30 inches

    Under Section 405.3.1, where partitions do not separate adjacent water closets, urinals or bidets, they may not be set closer than 30 inches center to center.

    Reference: 2021 Michigan Plumbing Code, 405.3.1

  4. Under Table 604.3, a flushometer-valve water closet (blow out) must have what minimum flow pressure at its supply outlet?

    Answer: 45 psi

    Table 604.3 lists 25 gpm at 45 psi for a blow-out flushometer valve water closet and 25 gpm at 35 psi for a siphonic flushometer closet. Tank-type closets need only 20 psi.

    Reference: 2021 Michigan Plumbing Code, Table 604.3

  5. How is the minimum required air gap measured under Section 608.14.1?

    Answer: Vertically from the lowest end of the potable outlet to the flood level rim of the receptacle

    Section 608.14.1 measures the air gap vertically from the lowest end of the potable water outlet to the flood level rim of the fixture or receptacle that it discharges into.

    Reference: 2021 Michigan Plumbing Code, 608.14.1

  6. What is the minimum number of roof drains required on a roof area of 8,000 square feet?

    Answer: 2

    Section 1110.4 requires at least two roof drains on roof areas of 10,000 square feet or less and at least four on roofs over 10,000 square feet.

    Reference: 2021 Michigan Plumbing Code, 1110.4

  7. A drainage system is tested with an air test. What gauge pressure must be held, and for how long?

    Answer: 5 psi for not less than 15 minutes

    Section 312.3 requires an air test at a uniform gauge pressure of 5 psi (or enough to balance a 10-inch column of mercury), held at least 15 minutes. Adjustments for temperature or gasket seating are made before the test period starts.

    Reference: 2021 Michigan Plumbing Code, 312.3

  8. A plumbing permit is issued and the work has not started. After how many days does it expire?

    Answer: 180 days

    Section 106.5.3 makes a permit null and void if work is not commenced within 180 days of issue or is suspended or abandoned for 180 days. The code official may grant a 180-day extension (106.5.4).

    Reference: 2021 Michigan Plumbing Code, 106.5.3, 106.5.4

  9. What experience must an applicant for a Michigan master plumber license have as a journey plumber, in addition to being 18 years old and passing the exam?

    Answer: 4,000 hours of journey plumber work over at least 2 years immediately before applying

    MCL 339.6113(1) requires a master applicant to be at least 18, hold a journey plumber license (or one under former 2002 PA 733) and have 4,000 hours as a journey plumber over at least 2 years immediately preceding the application. The 6,000 hours over 3 years is the apprentice experience required for the journey plumber license (MCL 339.6115).

    Reference: Skilled Trades Regulation Act, 2016 PA 407, MCL 339.6113(1)

  10. Exterior water supply piping must be installed at what minimum depth under Section 305.4?

    Answer: At least 6 inches below the frost line and at least 12 inches below grade

    Section 305.4 requires water, soil and waste piping to be protected from freezing, and exterior water supply piping to be not less than 6 inches below the frost line and not less than 12 inches below grade.

    Reference: 2021 Michigan Plumbing Code, 305.4

Sources

Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.