Requirements at a glance
| Agency | Michigan LARA, Bureau of Construction Codes; written exam by PSI |
|---|---|
| Exam | 125 questions, 3 hours, 75% to pass, plus a separate practical exam |
| Books allowed | 2021 Michigan Plumbing Code (chapter tabs only), 1972 PA 230 and 2016 PA 407 |
| Fees | $100 to PSI per attempt, plus LARA application and license fees |
| Experience | Age 18 or older and at least 6,000 hours over at least 3 years as a registered apprentice plumber under a master plumber (MCL 339.6115) |
Plumbers applying to LARA for a Michigan journey plumber license. Applicants since December 15, 2021 also take a separate practical exam, which this written-exam prep does not cover.
Official links
How to get licensed, step by step
Apply to LARA
Submit your journey plumber application with your documented hours. LARA approves you before you can pay for the exam.
Michigan LARA: Bureau of Construction Codes (opens in a new tab)
Schedule the written exam with PSI
Follow the instructions in your approval letter. Fail and you may retest, paying $100 each time. Online testing is not offered for the journey plumber.
Schedule with PSI (Michigan plumbing) (opens in a new tab)PSI: Michigan plumbing candidate bulletin (opens in a new tab)
Schedule the practical
Applications after December 15, 2021 also need a practical exam. Email LARA-BCC-Licensing@Michigan.Gov with your name and applicant ID to request a date.
LARA: PSI examinations for the Bureau of Construction Codes (opens in a new tab)
How to prepare
- Bring only what the bulletin allows. Michigan reference books must be bound and unmarked: no highlighting, underlining or loose papers.
- Michigan's codes are the 2021 Michigan Plumbing Code and Mechanical Code (the 2021 IPC and IMC with Michigan amendments) and the 2015 Michigan Residential Code. Study the Michigan text, not the model code.
- Only chapter tabs are allowed on the code book, so practice finding drainage, vent and water sizing tables fast from the chapter headings.
- Expect isometric drawing questions: practice counting fixture units and sizing drain and vent pipe from a riser diagram.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Michigan Plumbing Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 Michigan Plumbing Code (2021 IPC with Michigan amendments)Essential
The only code book allowed in the plumbing exam rooms (chapter tabs only). Code questions are based on this edition.
Skilled Trades Regulation Act, 2016 PA 407
Free online from the Michigan Legislature. The licensing law for plumbers and mechanical contractors; shown on screen in the plumbing exams.
Stille-DeRossett-Hale Single State Construction Code Act, 1972 PA 230
Free online from the Michigan Legislature. Permits, inspections and code enforcement; law questions draw on it.
Official reference list (as published by the testing agency)
- 2021 Michigan Plumbing Code book (chapter tabs only)
- State Construction Code Act, 1972 PA 230
- Skilled Trades Regulation Act, 2016 PA 407
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Drainage Systems | 25 | |
| Vent Systems | 20 | |
| Fixtures | 20 | |
| Water Distribution | 20 | |
| Backflow Prevention | 10 | |
| Special Waste Systems | 5 | |
| Testing and Inspections | 10 | |
| Isometric Drawings | 15 |
Exam day details
- Administered by PSI Services for the Michigan Department of Licensing and Regulatory Affairs (LARA), Bureau of Construction Codes.
- Fee: $100 to PSI per attempt, non-refundable and valid for one year. LARA application and license fees are separate.
- 125 questions in 3 hours; 75% to pass.
- The bulletin lists topics but no per-topic weights. Our topic weights are an estimate that adds up to 125.
- Journey plumber applications submitted after December 15, 2021 need two separate exams. The written exam is on PSI's computers; for the practical, email LARA-BCC-Licensing@Michigan.Gov with your name and applicant ID to be scheduled.
- Reference books must be bound and appear exactly as published: no highlighting, underlining, marking or loose papers, and only chapter tabs are allowed on the plumbing code book.
- If you fail you may retest an unlimited number of times, paying the exam fee for each attempt. Online remote testing is not available for the journey plumber.
- The Department (LARA BCC) must approve your application first. It sends a notification letter with instructions to pay and schedule with PSI; only the State decides eligibility.
- PSI may add up to ten unscored experimental questions; they are not counted in your score and don't take time from the exam.
- Cancel or reschedule at least 2 days before the appointment to keep your fee; late cancellations and no-shows forfeit it.
Frequently asked questions
What's on the Michigan journey plumber exam?
125 questions on drainage systems, vent systems, fixtures, water distribution, backflow prevention, special waste systems, testing and inspections, plus reading an isometric drawing.
Which code book does the Michigan journey plumber exam use?
The 2021 Michigan Plumbing Code, with chapter tabs only, plus 1972 PA 230 and 2016 PA 407.
Is there a practical exam too?
Yes. Applications submitted after December 15, 2021 need a separate practical exam that you schedule by email with LARA. Our bank covers the written exam only.
Free questions with answers
Show all 10 free questions and answers
A 4-inch horizontal drain collects kitchen waste and runs upstream of a grease interceptor. What is the minimum slope?
Answer: 1/4 inch per foot (2 percent)
Section 704.1 sets the general slopes in Table 704.1 (1/8 inch per foot for a 4-inch pipe) but makes an exception: drainage piping upstream of a grease interceptor must be sloped at not less than 1/4 inch per foot. The table value of 1/8 inch is the tempting wrong answer.
Reference: 2021 Michigan Plumbing Code, Section 704.1
A horizontal branch is to connect to the base of a 4-inch drainage stack. What is the minimum distance downstream of the stack at which the branch may connect?
Answer: 40 inches
Section 704.3 requires a horizontal branch to connect to the base of a stack not less than 10 times the stack diameter downstream: 10 x 4 inches = 40 inches. 24 inches comes from using a 2-inch pipe, and 80 inches from doubling the multiplier.
Reference: 2021 Michigan Plumbing Code, Section 704.3
The plumbing vent system must keep any fixture trap seal from being subjected to a pressure differential of more than what amount?
Answer: 1 inch of water column
Section 901.2 states the vent system must admit or release air so a trap seal never sees more than 1 inch of water column (249 Pa) of pressure differential.
Reference: 2021 Michigan Plumbing Code, Section 901.2
An open vent pipe passes through a roof that is used as a sun deck. How far above the roof surface must the vent terminate?
Answer: Not less than 7 feet
Section 903.1 requires open vents through a roof to extend at least 1 foot above it, but where the roof is used for any purpose other than weather protection the extension must be at least 7 feet.
Reference: 2021 Michigan Plumbing Code, Section 903.1
A row of floor-mounted water closets has no partitions between them. What is the minimum center-to-center spacing between two adjacent water closets?
Answer: 30 inches
Section 405.3.1: where partitions do not separate adjacent water closets, urinals or bidets, they must be at least 30 inches center to center. The 15-inch figure is the distance from the centerline to a side wall, and 21 inches is the clear space in front of the fixture.
Reference: 2021 Michigan Plumbing Code, Section 405.3.1
A water service pipe crosses over a building sewer that is not a Table 702.2 material, and no sleeve is used. What vertical clearance satisfies the exception to the 5-foot separation?
Answer: The bottom of the water service at least 12 inches above the top of the sewer
Section 603.2 waives the 5-foot separation where the bottom of the water service pipe, within 5 feet of the sewer, is not less than 12 inches above the highest point of the top of the building sewer. Water lines go above sewers, never below.
Reference: 2021 Michigan Plumbing Code, Section 603.2
Potable water outlets and combination stop-and-waste valves are prohibited in which location?
Answer: Underground or below grade
Section 608.8 prohibits potable water outlets and combination stop-and-waste valves underground or below grade. A freezeproof yard hydrant that drains the riser into the ground counts as having one, subject to a limited exception.
Reference: 2021 Michigan Plumbing Code, Section 608.8
A drainage system is water tested in sections. What is the minimum head of water that each section must be tested under?
Answer: 10 feet
Section 312.2 requires sections to be tested with not less than a 10-foot head of water, with the upper 10 feet of the preceding section retested, and the pressure held for at least 15 minutes.
Reference: 2021 Michigan Plumbing Code, Section 312.2
Which statement about an oil separator in a repair garage is correct under Section 1003.4.2.1?
Answer: It is at least 2 feet deep below the drain invert, with an 18-inch water seal
Section 1003.4.2.1 requires oil separators to have a depth of not less than 2 feet below the invert of the discharge drain and an outlet opening with not less than an 18-inch water seal. Sand interceptors need a 6-inch seal (Section 1003.5).
Reference: 2021 Michigan Plumbing Code, Section 1003.4.2.1
An isometric shows a 4-inch building drain leaving the building at an invert 30 inches below the floor and running 60 feet to the sewer connection at 1/4 inch per foot. How deep below the floor is the invert at the sewer end?
Answer: 45 inches
The fall is 60 ft x 1/4 inch = 15 inches. Pipe slopes down in the direction of flow, so the invert is 30 + 15 = 45 inches below the floor. 37-1/2 uses 1/8 inch per foot. 15 inches forgets the starting depth.
Reference: 2021 Michigan Plumbing Code, Section 704.1
Sources
- PSI: Michigan Plumbing Examinations Candidate Information Bulletin (effective 4/29/2026) (opens in a new tab)
- Michigan LARA: Bureau of Construction Codes (opens in a new tab)
- LARA: PSI examinations for the Bureau of Construction Codes (opens in a new tab)
- LARA: Michigan code books and adopted codes (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.