Question 1 of 10Wiring and Protection

A journeyperson is installing the service for a new one-family house with a calculated load of only 62 amperes. What is the minimum rating of the service disconnecting means?

Requirements at a glance

AgencyMaryland State Board of Electricians; exam by PSI
Experience4 years of regular, principal electrical work under a master electrician (or a similar qualified government employee); the Board may credit up to 3 years for a formal electrical course.
Exam70 questions, 3.5 hours, 49 correct (70%) to pass
Books allowed2020 NEC (tabs allowed)
Fees$65 to PSI, plus Board application and license fees

Electricians applying for a Maryland journeyperson electrician license from the State Board of Electricians, usually after 4 years of experience under a master electrician (up to 3 years of credit for approved school).

How to get licensed, step by step

  1. Confirm you qualify

    4 years of regular, principal electrical work under a master electrician (or a similar qualified government employee); the Board may credit up to 3 years for a formal electrical course.

    Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)Maryland Code (General Assembly) (opens in a new tab)

  2. Apply through PSI

    Submit the exam application online at the PSI site below (mailed or faxed applications are returned). PSI and the Board review your documents, then email you how to pay and schedule.

    Schedule with PSI (electricians) (opens in a new tab)

  3. Pass the open-book exam

    Exam fees are non-refundable and non-transferable. If you fail, wait 30 days from your last attempt before retaking.

    Schedule with PSI (electricians) (opens in a new tab)

  4. Apply for the license

    After you pass, the Board sends you the license application. Pay the license fee and file any required insurance.

    Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)

How to prepare

  • Tab your books before exam day: permanent plastic tabs (Avery Swift or Redi-Tag), highlighting and underlining are allowed; Post-It flags and writing in the book are not.
  • Bring the 2020 NEC, the only reference allowed in the room. PSI supplies an on-screen calculator, but tabs and a clear index save the most time.
  • Electrical theory is a big block of both exams (20 of the points or questions): practice Ohm's law, power, series and parallel circuits and AC basics.
  • Wiring and protection (20 questions) is as big as theory: tab Articles 110, 210, 215, 220, 230, 240 and 250.
  • The bulletin (updated 9/1/2024) lists the 2020 NEC; the Board is preparing 2026 NEC questions, so check the current bulletin.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2020 EditionEssential

    The only reference allowed in the exam room. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 430 and Chapter 9. The Board is moving toward the 2026 NEC, so check the current bulletin.

    NFPA store (opens in a new tab)

Official reference list (as published by the testing agency)
  • National Electrical Code (NFPA 70), 2020 edition (the only reference allowed in the exam room; tabs allowed)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Electrical Theory20
Wiring and Protection20
Wiring Methods and Materials12
Equipment for General Use6
Special Occupancies4
Special Equipment2
Special Communications6

Exam day details

  • Administered by PSI Services for the Maryland State Board of Electricians.
  • Fee: $65 to PSI per exam. Board application and license fees are separate.
  • 70 questions in 3.5 hours; 49 correct (70%) to pass. There is no separate calculations section, but theory questions use calculations.
  • Edition note: The PSI bulletin (updated 9/1/2024) lists the 2020 NEC. The Board has said it is preparing exam questions for the 2026 NEC, so check the current PSI bulletin for the edition on your test date.
  • Open book: the 2020 NEC is the only reference allowed in the room, and PSI does not provide it. You may tab it with Avery Swift or Redi-Tag permanent plastic tabs; Post-It flags are not allowed.
  • PSI gives you an on-screen calculator. Study guides are not allowed in the room.
  • PSI adds five to ten unscored experimental questions; the time spent on them does not count against your exam time.
  • Apply to PSI online first; once approved you receive an email on how to pay and schedule. The exam fee is non-refundable and non-transferable.
  • If you fail, wait 30 days from your last attempt before retaking the exam.

Frequently asked questions

What's on the Maryland journeyperson electrician exam?

70 questions: electrical theory 20, wiring and protection 20, wiring methods and materials 12, equipment for general use 6, special communications 6, special occupancies 4 and special equipment 2.

How many questions do I need to pass?

49 of 70 (70%).

Is the journeyperson exam open book?

Yes. You may bring the 2020 NEC, tabbed with permanent plastic tabs, and you get an on-screen calculator.

Free questions with answers

Show all 10 free questions and answers
  1. A journeyperson is installing the service for a new one-family house with a calculated load of only 62 amperes. What is the minimum rating of the service disconnecting means?

    Answer: 100 amperes, 3-wire

    230.79(C) sets the minimum for a one-family dwelling at 100 amperes, 3-wire, no matter how small the calculated load is. The lower values in 230.79(A), (B) and (D) apply to other occupancies and to very small installations, not to a one-family dwelling.

    Reference: NEC 2020 (NFPA 70), 230.79(C)

  2. Overhead 120/240-volt service conductors run across the driveway of a duplex, which is not subject to truck traffic. What is the minimum clearance above final grade?

    Answer: 12 feet

    230.24(B)(2) requires 12 ft over residential property and driveways, and over commercial areas not subject to truck traffic, where voltage to ground is 300 V or less. 18 ft applies over public streets, alleys and roads (230.24(B)(4)); 10 ft is the lower value for areas accessible only to pedestrians.

    Reference: NEC 2020 (NFPA 70), 230.24(B)(2)

  3. Intermediate metal conduit (IMC) carrying a 208Y/120-volt feeder will be buried under an open lawn, away from buildings, driveways and roads. What is the minimum cover?

    Answer: 6 inches

    Table 300.5 gives 6 in. of cover for rigid metal conduit and intermediate metal conduit in the general 'all locations not specified' row. 18 in. is the value for listed nonmetallic raceways, and 24 in. applies to direct-buried cables.

    Reference: NEC 2020 (NFPA 70), Table 300.5

  4. A 240-volt feeder in Schedule 40 rigid PVC conduit crosses an open yard with no vehicle traffic and is not under a building or slab. How much earth cover must be over the conduit at minimum?

    Answer: 18 inches

    Table 300.5 gives 18 in. of cover for listed nonmetallic raceways (such as rigid PVC) in the general 'all locations not specified' row. The 12-in. value only applies to residential branch circuits of 120 volts or less with GFCI protection and 20 A or less overcurrent protection.

    Reference: NEC 2020 (NFPA 70), Table 300.5

  5. A 10-hp, 230-volt, three-phase squirrel-cage motor has a Table 430.250 full-load current of 28 amperes and starts normally. Using the table percentage for an inverse-time breaker, what is the maximum standard breaker rating for branch-circuit short-circuit and ground-fault protection?

    Answer: 70 amperes (28 A x 250 percent = 70 A)

    Table 430.52 allows an inverse-time breaker up to 250 percent of the full-load current for a squirrel-cage motor: 28 x 2.5 = 70 A, which is a standard size in 240.6(A). 300 percent is the value for instantaneous-trip breakers and 125 percent is the 430.22 conductor factor.

    Reference: NEC 2020 (NFPA 70), Table 430.52; 240.6(A)

  6. Which wiring method is permitted by Article 501 for general use in a Class I, Division 1 location?

    Answer: Threaded rigid metal conduit

    501.10(A)(1) permits threaded rigid metal conduit, threaded steel intermediate metal conduit, and certain listed cables such as Type MI and Type MC-HL cable, installed with listed fittings. EMT, NM cable and nonmetallic flexible conduit are not permitted wiring methods in Division 1 locations.

    Reference: NEC 2020 (NFPA 70), 501.10(A)(1)

  7. A permanently installed swimming pool at a single-family dwelling needs the required general-purpose 125-volt receptacle. What distance range from the inside wall of the pool is required?

    Answer: At least 6 ft but not more than 20 ft

    680.22(A)(1) requires at least one 125-volt, 15- or 20-ampere receptacle on a general-purpose branch circuit, located at least 6 ft and not more than 20 ft from the inside wall of the pool. The receptacle must also not be more than 6 ft 6 in. above the floor, platform or grade serving the pool.

    Reference: NEC 2020 (NFPA 70), 680.22(A)(1)

  8. A Class 2 thermostat cable will be pulled to a rooftop unit. May it share a raceway with the 120-volt branch-circuit conductors that feed the unit?

    Answer: Not unless one of the specific exceptions in 725.136 is met

    725.136 does not allow Class 2 and Class 3 conductors in the same cable, enclosure or raceway with electric light, power, Class 1 or non-power-limited fire alarm conductors unless an exception applies, such as separation by a barrier or termination in a connection block. Jacket voltage rating, raceway material and conductor size are not the test.

    Reference: NEC 2020 (NFPA 70), 725.136

  9. A conductor with a resistance of 0.5 ohm carries 20 amperes. How much power is lost as heat in the conductor?

    Answer: 200 watts

    Heat loss is P = I squared x R = 20 x 20 x 0.5 = 200 W. Multiplying current by resistance without squaring the current gives 10, which is a voltage (10 V), not power.

    Reference: General electrical theory, Power formula, P = I squared x R

  10. A balanced three-phase 208-volt load draws 30 amperes per line at a power factor of 0.8. What is the true power in watts (use 1.732 for the square root of 3)?

    Answer: 8,646 watts (1.732 x 208 x 30 x 0.8)

    Three-phase true power is P = 1.732 x E x I x PF = 1.732 x 208 x 30 x 0.8. 1.732 x 208 x 30 = 10,808 VA, and 10,808 x 0.8 = 8,646 W. Leaving out the power factor gives the apparent power, and using 3 in place of 1.732 overstates it.

    Reference: General electrical theory, Three-phase power formula