Requirements at a glance
| Agency | Louisiana State Licensing Board for Contractors (LSLBC); exams by PSI |
|---|---|
| Exam | 100 questions, 4 hours, 70% |
| Books allowed | 2023 NEC, Ugly's (2011, 2014 or 2017) and 29 CFR 1926 |
| Requirements | Business and Law course (not an exam), net worth statement, insurance and other LSLBC requirements |
| Fees | $140 to PSI, plus LSLBC application and license fees |
Qualifying parties for a Louisiana commercial electrical contractor license (Electrical Work Statewide) from the LSLBC. Louisiana has no state journeyman or master electrician exam; those cards are issued locally.
Official links
How to get licensed, step by step
Apply to the LSLBC
Submit an application for licensure, or a request to add a classification or qualifying party to your license. The Board reviews it before you can test.
LSLBC: apply for a license (opens in a new tab)Louisiana State Licensing Board for Contractors (LSLBC) (opens in a new tab)
Schedule with PSI
Once approved you get an e-mail from PSI to pay and schedule. Eligibility is good for one year; after that you reapply with the Board.
Schedule with PSI (Louisiana contractors) (opens in a new tab)
Take the open-book exam
Bring your own tabbed references. 70% is passing.
Schedule with PSI (Louisiana contractors) (opens in a new tab)
Finish your license
Complete the Business and Law course and the remaining LSLBC requirements to be licensed.
Louisiana State Licensing Board for Contractors (LSLBC) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline. Louisiana's adopted codes are the 2021 ICC codes and the 2020 NEC, but several PSI exams list other editions (the 2023 NEC, 2018 ICC books). The 2023 NEC and 2024 ICC codes take effect January 1, 2027.
- Tab your books before exam day. You can highlight, underline and index them with permanent tabs, but you can't write in them, and sticky notes are removed.
- Grounding and bonding, services, feeders and branch circuits, special occupancies and lighting are 10 questions each: tab Articles 210, 215, 220, 230, 250, 410 and 680 plus Chapter 9.
- The 2023 NEC is tested even though Louisiana currently enforces the 2020 NEC; practice with the 2023 numbering.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 EditionEssential
Allowed in the exam room. PSI says the Electrical Statewide exam is based only on this edition.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Ugly's Electrical References (2011, 2014 or 2017 edition)
Allowed in the exam room. Formulas for voltage drop, power, motors and transformers.
29 CFR Part 1926: Safety and Health Regulations for Construction
Allowed in the room for the electrical, mechanical and building exams. Free online from OSHA.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 Edition (the exam is based only on this edition)
- Ugly's Electrical References, 2011, 2014 or 2017 edition
- 29 CFR Part 1926 (OSHA construction standards), latest amendments
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 4 | |
| General Electrical Knowledge | 10 | |
| Electrical Installation Requirements | 10 | |
| Services, Feeders, and Branch Circuits | 10 | |
| Overcurrent Protection | 9 | |
| Grounding and Bonding | 10 | |
| Conductors and Cables | 8 | |
| Raceways and Boxes | 7 | |
| Special Occupancies and Equipment (Including Swimming Pools) | 10 | |
| Low Voltage, Alarms, Signaling Systems, and Communications | 2 | |
| Lighting and Signs | 10 | |
| Safety | 4 | |
| Motors and Transformers | 6 |
Exam day details
- Administered by PSI Services for the Louisiana State Licensing Board for Contractors (LSLBC).
- Fee: $140 to PSI. LSLBC application and license fees are separate.
- 100 questions in 4 hours; 70 correct (70%) to pass.
- Louisiana's adopted codes are the 2021 ICC codes and the 2020 NEC; the 2023 NEC and 2024 ICC codes take effect January 1, 2027. PSI's exams cite specific editions, so our questions name the edition they use.
- Open book: bring your own copies of the allowed references. You may highlight, underline and index them beforehand, but not write in them during the exam. Temporary tabs such as sticky notes are removed.
- PSI may add unscored experimental questions, which count against your time.
- The LSLBC must approve your application (or your request to add a classification) first. PSI then e-mails your eligibility, which is good for one year; if you haven't passed by then you reapply with the Board.
- Business and Law is a required course, not an exam, so there is no separate business exam to take.
- Code questions are based only on the edition PSI lists. For other references, later editions are fine.
Frequently asked questions
What's on the Louisiana Electrical Statewide exam?
100 questions: general electrical knowledge, electrical installation requirements, services, feeders and branch circuits, grounding and bonding, special occupancies and equipment, and lighting and signs 10 each; overcurrent protection 9; conductors and cables 8; raceways and boxes 7; motors and transformers 6; general knowledge and safety 4 each; low voltage and alarms 2.
Which NEC edition is on the Louisiana electrical exam?
The 2023 NEC. Louisiana's adopted code is still the 2020 NEC until the 2023 NEC takes effect January 1, 2027, but PSI's outline says the exam is based only on the 2023 edition.
Does Louisiana have a journeyman electrician exam?
Not a state one. Journeyman and master electrician cards are issued by local jurisdictions such as New Orleans, Jefferson Parish and Baton Rouge. The LSLBC Electrical Statewide exam is for the contractor license.
Free questions with answers
Show all 10 free questions and answers
Three resistive loads of 15, 30 and 10 ohms are connected in parallel across the same source. What is the equivalent resistance?
Answer: 5 ohms
1/Rt = 1/15 + 1/30 + 1/10 = 2/30 + 1/30 + 3/30 = 6/30, so Rt = 5 ohms. Parallel resistance is always smaller than the smallest branch. 55 ohms is the series total and 18.3 ohms is a simple average.
Reference: NFPA 70, National Electrical Code, 2023, Parallel circuits (Ugly's, Chapter 1 formulas)
A new panelboard is 42 inches wide. What is the minimum width of the working space in front of it under 110.26(A)(2)?
Answer: 42 in.
The width of the working space must be at least 30 in. or the width of the equipment, whichever is greater. A 42-in. panelboard therefore needs a 42-in. wide working space; 30 in. applies only to narrower equipment.
Reference: NFPA 70, National Electrical Code, 2023, 110.26(A)(2)
A feeder supplies 70 A of continuous load and 30 A of noncontinuous load. Before any adjustment or correction factors, what is the minimum feeder conductor ampacity under 215.2(A)(1)?
Answer: 117.5 A
Minimum ampacity = 125% of continuous load plus 100% of noncontinuous load = (70 x 1.25) + 30 = 87.5 + 30 = 117.5 A. 100 A ignores the 125 percent factor, 125 A applies 125 percent to everything, and 87.5 A leaves out the noncontinuous load.
Reference: NFPA 70, National Electrical Code, 2023, 215.2(A)(1)
A feeder uses 4 AWG THWN copper at 75°C. Table 310.16 gives 85 A, and 85 A is not a standard rating. Under 240.4(B), what is the maximum standard overcurrent device if the circuit is not a multioutlet receptacle circuit?
Answer: 90 A
Section 240.4(B) permits the next higher standard rating (240.6(A)) above the conductor ampacity when the device is 800 A or less and the other conditions are met. The next standard size above 85 A is 90 A. 100 A is two steps up, and 85 A is not a standard rating.
Reference: NFPA 70, National Electrical Code, 2023, 240.4(B) and Table 310.16
A copper circuit has its ungrounded conductors increased in size to limit voltage drop. How must the equipment grounding conductor be treated under 250.122(B)?
Answer: It must be increased proportionally by circular mil area
Section 250.122(B) requires the equipment grounding conductor to be adjusted in size proportionally, according to circular mil area, when ungrounded conductors are increased in size for any reason (such as voltage drop). The Table 250.122 size is the minimum for the unadjusted conductors.
Reference: NFPA 70, National Electrical Code, 2023, 250.122(B)
An 8 AWG copper THHN conductor (90°C ampacity 55 A) runs through a space with a 45°C ambient. Using the 90°C correction factor of 0.87 for 41 to 45°C, what is the corrected ampacity?
Answer: 47.9 A
Corrected ampacity = 55 A x 0.87 = 47.85 A, about 47.9 A. 50.1 A (55 x 0.91) uses the factor for the 36 to 40°C band, and 45.1 A (55 x 0.82) uses the 46 to 50°C band. 55 A ignores the temperature correction.
Reference: NFPA 70, National Electrical Code, 2023, Table 310.15(B)(1)(1) and Table 310.16
What is the maximum percentage of a conduit's cross-sectional area that two conductors may fill under Chapter 9, Table 1?
Answer: 31 percent
Chapter 9 Table 1 permits 53 percent fill for one conductor, 31 percent for two conductors, and 40 percent for over two conductors. 53 percent is the one-conductor value and 40 percent is the over-two value.
Reference: NFPA 70, National Electrical Code, 2023, Chapter 9, Table 1
Flour, starch and grain dust create which hazardous (classified) location group under Article 500?
Answer: Class II, Group G
Combustible dusts are Class II locations. Group G covers flour, starch, grain and similar dusts, Group F covers carbon-based dusts such as coal and Group E covers metal dusts. Class III covers ignitable fibers and flyings, and Class I, Group D covers gases such as propane.
Reference: NFPA 70, National Electrical Code, 2023, 500.6(B)(3)
A 20-hp, 460-volt, three-phase squirrel-cage motor has a Table 430.250 full-load current of 27 A. What is the minimum ampacity of the branch-circuit conductors under 430.22?
Answer: 33.75 A
Branch-circuit conductors to a single continuous-duty motor must have an ampacity of at least 125 percent of the full-load current from Table 430.250: 27 x 1.25 = 33.75 A. 27 A omits the factor, 40.5 A applies 150 percent, and 67.5 A is the 250 percent value used for the breaker.
Reference: NFPA 70, National Electrical Code, 2023, 430.22 and Table 430.250
A new commercial occupancy has a ground-floor tenant space accessible to pedestrians. What does 600.5(A) require for the sign or outline lighting?
Answer: One outlet at each tenant entrance, on a 20-A circuit serving no other load
Section 600.5(A) requires each commercial building and occupancy accessible to pedestrians to have at least one outlet in an accessible location at each entrance to each tenant space for sign or outline lighting, supplied by a branch circuit rated at least 20 A that supplies no other load. Sharing the circuit with lobby lighting violates the no-other-load rule, and nothing requires a 30-A circuit.
Reference: NFPA 70, National Electrical Code, 2023, 600.5(A)
Sources
- PSI: Louisiana contractor exam registration (LSLBC) (opens in a new tab)
- Louisiana State Licensing Board for Contractors (LSLBC) (opens in a new tab)
- PSI: Louisiana LSLBC Electrical Statewide content outline (opens in a new tab)
- Louisiana State Uniform Construction Code Council (adopted codes) (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.