Requirements at a glance
| Agency | Kentucky DHBC, Division of Electrical; exam by ICC at Pearson VUE |
|---|---|
| Experience | 8,000 hours of verifiable experience, up to 4,000 hours credit for training (KRS 227A.060) |
| Exam | 80 questions, 4 hours, 70% to pass |
| Books allowed | 2023 NEC and Ugly's Electrical References (any edition) |
| Fees | $100 exam; DHBC application and license fees are separate |
Applicants for a Kentucky electrician license (the journeyman-level license) from the Department of Housing, Buildings and Construction.
Official links
How to get licensed, step by step
Apply to DHBC
Send DHBC your license application with proof of experience. Licenses are issued by the Department, not the testing vendor.
Kentucky Department of Housing, Buildings and Construction (DHBC) (opens in a new tab)Kentucky Revised Statutes (KRS 227A, 198B, 318) (opens in a new tab)
Schedule the journeyman electrician exam
Register and pay the $100 exam fee ($60 for Business and Law) for a Pearson VUE testing center. If you fail, you wait 10 days before you retest. Schedule through Pearson VUE (ICC); DHBC also accepts Prov and NASCLA electrical results.
ICC: Kentucky candidate bulletin (1/17/2026) (opens in a new tab)DHBC: Electrical new application checklists (2/4/2025) (opens in a new tab)
Pass and get licensed
You need 70% to pass. Your passing score is valid for 3 years, so file your license application and any required insurance before it expires.
Kentucky Department of Housing, Buildings and Construction (DHBC) (opens in a new tab)815 KAR: DHBC administrative regulations (opens in a new tab)
How to prepare
- Bring the exact editions on the bulletin: the 2023 NEC for electricians and the 2015 IMC with NFPA 54 (2009) for HVAC (the 2018 Kentucky Building Code references NFPA 54 2012, but the bulletin lists 2009). Kentucky amends the NEC, so read the state amendments.
- Tab your books before exam day. Both ICC electrical and HVAC exams are open book with four-option questions.
- Wiring methods and materials is 26% of the exam: know Chapter 3 raceways and cables, Articles 300 and 314.
- Branch circuits and conductors (19%) rewards fluency with Table 310.16, Article 210 and Article 220.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 EditionEssential
The edition named in the ICC Kentucky bulletin. Kentucky adopts it with amendments.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for voltage drop, power, motors and transformers.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 edition
- Ugly's Electrical References (any edition)
What's on the exam
Official content outline from ICC (Pearson VUE) (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 6 | |
| Services and Service Equipment | 11 | |
| Feeders | 4 | |
| Branch Circuits and Conductors | 19 | |
| Wiring Methods and Materials | 26 | |
| Equipment and Devices | 13 | |
| Control Devices | 4 | |
| Motors and Generators | 6 | |
| Special Occupancies, Equipment, and Conditions | 11 |
The outline totals 100; the other items on the 80-question exam are unscored or unassigned.
Exam day details
- Administered by ICC (Pearson VUE) for the Kentucky Department of Housing, Buildings and Construction.
- Fee: $100 to Pearson VUE per exam. DHBC application and license fees are separate.
- 80 questions in 4 hours; 70% to pass (815 KAR 35:060).
- Electrician license: 8,000 hours of verifiable experience, with up to 4,000 hours of credit for approved training or school (KRS 227A.060).
- Kentucky also accepts the NASCLA journeyman electrician exam (100 questions, 300 minutes, 70% to pass); NASCLA scores are valid for 3 years.
- Open book: bring your own copies of the listed references. Check the ICC bulletin for what tabbing and highlighting is allowed.
- If you fail, you wait 10 days before you retake the exam.
- A passing score is valid for 3 years (815 KAR 35:060 for electricians; 815 KAR 8:010 for HVAC).
Note: DHBC accepts Pearson VUE (ICC), Prov and NASCLA electrical exams, and gives its own in-person HVAC exams; Pearson VUE is the ICC route in the 1/17/2026 bulletin. The ICC bulletin is the source for the format and topic weights, and the 70% pass score is from 815 KAR 35:060 and 815 KAR 8:010.
Frequently asked questions
What is on the Kentucky journeyman electrician exam?
80 questions: wiring methods and materials 26%, branch circuits and conductors 19%, equipment and devices 13%, services 11%, special occupancies 11%, general knowledge 6%, motors and generators 6%, feeders 4% and control devices 4%.
Is there a separate journeyman license in Kentucky?
Kentucky calls the journeyman-level license simply an electrician license. The exam is titled Kentucky Standard Journeyman Electrician.
How much experience do I need?
8,000 hours of verifiable electrical experience, with up to 4,000 hours of credit for approved training, under KRS 227A.060.
Free questions with answers
Show all 10 free questions and answers
A commercial service supplies 48 amperes of noncontinuous load and 40 amperes of continuous load. Using only the loads, what is the minimum ampacity required of the service-entrance conductors?
Answer: 98 amperes
Section 230.42(A)(1) requires an ampacity not less than the noncontinuous load plus 125 percent of the continuous load. Calculation: 48 + (40 x 1.25) = 48 + 50 = 98 A. Adding the loads without the 125 percent gives 88 A, applying 125 percent to the noncontinuous load gives 100 A, and applying it to both gives 110 A.
Reference: 2023 National Electrical Code (NFPA 70), 230.42(A)(1)
A 20-ampere branch circuit supplies several receptacle outlets. Which receptacle ratings are permitted on it?
Answer: 15 A or 20 A
Table 210.21(B)(3) permits 15 or 20 ampere receptacles on a 20 ampere circuit that serves two or more receptacles or outlets. A 30 ampere receptacle is allowed only on a 30 ampere circuit.
Reference: 2023 National Electrical Code (NFPA 70), Table 210.21(B)(3)
How many sets of 3-wire feeders are permitted to share one common neutral conductor?
Answer: Up to three sets
Section 215.4(A) allows up to three sets of 3-wire feeders, or two sets of 4-wire or 5-wire feeders, to use a common neutral. Section 215.4(B) requires all conductors of those feeders to be in the same metal raceway or enclosure when metal is used.
Reference: 2023 National Electrical Code (NFPA 70), 215.4(A)
A direct-buried Type UF cable crosses under the gravel driveway of a one-family dwelling, a driveway used only for dwelling-related purposes. What minimum cover does Table 300.5(A) require for the cable?
Answer: 18 in.
In Table 300.5(A), Column 1 (direct burial cables) gives 18 in. for one- and two-family dwelling driveways and outdoor parking areas used only for dwelling-related purposes. 24 in. is the general direct-burial depth for locations not otherwise listed, and 12 in. applies only to qualifying 120-volt, 20 A GFCI-protected residential branch circuits.
Reference: 2023 National Electrical Code (NFPA 70), Table 300.5(A)
What is the minimum burial depth for rigid metal conduit in an ordinary outdoor location with no special conditions?
Answer: 6 in.
Table 300.5(A), Column 2, lists 150 mm (6 in.) of cover for rigid metal conduit or intermediate metal conduit in locations not otherwise specified. Direct-buried cable needs 24 in. and nonmetallic raceways need 18 in.
Reference: 2023 National Electrical Code (NFPA 70), Table 300.5(A)
A floor-mounted switchboard is 7 ft 3 in. tall. What is the minimum clear height of its working space under 110.26(A)(3)?
Answer: 7 ft 3 in.
Section 110.26(A)(3) requires the working space to extend from the floor to 6 1/2 ft or the height of the equipment, whichever is greater. The equipment is taller than 6 1/2 ft, so the space must be clear to 7 ft 3 in.
Reference: 2023 National Electrical Code (NFPA 70), 110.26(A)(3)
A 3-phase machine feeder has conductors with a 75 C ampacity of 65 A. The load is not a multioutlet receptacle circuit and no standard overcurrent size matches 65 A. What is the largest standard overcurrent device permitted?
Answer: 70 A
Section 240.4(B) permits the next higher standard overcurrent device rating above the conductor ampacity if the conductors do not supply multioutlet receptacle branch circuits, the ampacity does not match a standard rating, and the next higher rating does not exceed 800 A. The standard ratings in 240.6(A) go from 60 to 70 A. A 65 A device is not a standard size.
Reference: 2023 National Electrical Code (NFPA 70), 240.4(B) and 240.6(A)
A 120-volt motor drawing 15 A is controlled by an ac general-use snap switch. What is the minimum switch ampere rating when the motor load may not exceed 80 percent of the switch rating?
Answer: 20 A
Section 404.14(A)(4) limits motor loads on an ac general-use snap switch to 80 percent of the switch ampere rating at its rated voltage. Calculation: 15 / 0.80 = 18.75 A, so the next standard switch rating is 20 A. A 15 A switch would be loaded to 100 percent.
Reference: 2023 National Electrical Code (NFPA 70), 404.14(A)
A 3-phase, 460-volt, 25 hp squirrel-cage motor has a nameplate current of 32 A. What is the minimum branch-circuit conductor ampacity for continuous duty?
Answer: 42.5 A
Section 430.6(A)(1) requires the Table 430.250 full-load current, not the nameplate current, for conductor sizing. For 25 hp at 460 volts the table value is 34 A. Section 430.22 requires 125 percent: 34 x 1.25 = 42.5 A. The 40.0 A answer uses the nameplate current (32 x 1.25), and 34.0 A omits the 125 percent factor.
Reference: 2023 National Electrical Code (NFPA 70), 430.6(A)(1) and 430.22
Which switch arrangement is NOT permitted for the switches that control an emergency lighting circuit?
Answer: A 3-way switch controlling the emergency lighting
Section 700.20 requires switches in emergency lighting circuits to be arranged so only authorized persons control the lighting, and says switches connected in series, and 3-way and 4-way switches, shall not be used. The parallel single-throw arrangement is Exception No. 1, and extra switches that only put the lights into operation are allowed by Exception No. 2.
Reference: 2023 National Electrical Code (NFPA 70), 700.20
Sources
- ICC: Kentucky candidate bulletin (1/17/2026) (opens in a new tab)
- Kentucky Department of Housing, Buildings and Construction (opens in a new tab)
- 815 KAR (Kentucky Administrative Regulations, Title 815) (opens in a new tab)
Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.