Kansas licensing exam

Kansas Journeyman Plumber Exam with Gas (ICC KGR): Practice Test & Licensing Guide

The ICC Kansas Standard Journeyman Plumber w/Gas exam (KGR): 70 open-book questions on the 2018 IPC and 2018 IFGC. 75% to pass.

Questions
70
Time limit
3 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Administration General Knowledge

A permit is issued on March 1, but the crew never starts the permitted work. Under the IPC, the permit becomes null and void if work is not commenced within how many days of the permit date, and what is required before work can then begin?

Requirements at a glance

AgencyYour Kansas city or county licenses you; the International Code Council (ICC) gives the exam through Pearson VUE. There is no statewide license
ExperienceSet by your city or county. Sedgwick County/Wichita: 2 years in the field, or 1 year in the field plus 1 year of trade school, for a journeyman certificate
ExamKGR: 70 questions, 3 hours, 75%
Books allowed2018 International Plumbing Code and 2018 International Fuel Gas Code
Fees$115 per ICC exam (national T-series exams are $120), plus your city or county's certificate or license fees

Plumbers applying for a journeyman certificate or license from a Kansas city or county that accepts the ICC standard exam, such as Sedgwick County/Wichita or Johnson County.

How to get licensed, step by step

  1. Ask your city or county which exam it accepts

    Kansas law lets each jurisdiction name the standard examinations it accepts as proof of competency. Confirm the exam and the experience rules before you pay.

    Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)Kansas statute K.S.A. 12-1525 (standard examinations) (opens in a new tab)

  2. Register for the journeyman plumber exam (KGR) with ICC and Pearson VUE

    Create an ICC account, pick the Kansas standard exam from the Exam Catalog and schedule a Pearson VUE appointment. If you fail, wait 10 days to retake.

    Schedule with Pearson VUE (ICC exams) (opens in a new tab)ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)

  3. Pass at 75% with your books

    The exam is open book with four-option multiple choice and no penalty for guessing. Bring only the approved references.

    ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)

  4. Apply to your city or county

    Send your passing score and proof of experience to the jurisdiction, with its fee. It issues the certificate or license and sets renewal rules.

    Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)

How to prepare

  • Study the edition the exam is built on: the 2017 NEC for electrical and the 2018 IPC, IMC and IFGC for plumbing and mechanical. Your city's adopted code can be newer.
  • The exam is open book, but there is not time to look up every answer. Tab your books by chapter and table before exam day.
  • The 2014 NEC / 2015 I-Code Kansas exams end December 1, 2026. If your jurisdiction wants a 2021-based exam, ask about the national ICC T-series instead.
  • Administration and general knowledge (34%) is the biggest area: IPC Chapter 1, Chapter 2 definitions, materials (Chapter 6) and testing.
  • Gas piping (19%) comes from the IFGC: pipe sizing tables, appliance connections, combustion air and venting basics.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • 2018 International Plumbing Code (IPC) (allowed in the exam room)
  • 2018 International Fuel Gas Code (IFGC) (allowed in the exam room)

What's on the exam

Official content outline from International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):

TopicQuestions
Administration General Knowledge34
Plumbing Fixtures11
Water Supply and Distribution11
Sanitary Drainage9
Plumbing Vent Requirements7
Traps, Interceptors, and Separators7
Storm Drainage2
Gas Piping19

The outline totals 100; the other items on the 70-question exam are unscored or unassigned.

Exam day details

  • Administered by International Code Council (ICC), delivered by Pearson VUE, for Kansas cities and counties.
  • Fee: $115 to ICC through Pearson VUE per exam. Your city or county's license fees are separate.
  • 70 multiple-choice questions in 3 hours; 53 correct (75%) to pass.
  • Open book: bring the approved references. Questions are four-option multiple choice with no penalty for guessing; 75% to pass.
  • Kansas has no statewide electrician, plumber or mechanical license. ICC only tests; the city or county where you want to work sponsors you and issues the license.
  • If you fail, wait 10 days to retake.
  • The 2014 NEC / 2015 I-Code exams stop being offered December 1, 2026. These Kansas standard exams are based on the 2017 NEC and 2018 I-Codes; the national T-series exams cover the 2020 NEC and 2021 I-Codes.

Frequently asked questions

What's on the Kansas journeyman plumber exam?

70 questions by weight: administration and general knowledge 34%, gas piping 19%, plumbing fixtures 11%, water supply and distribution 11%, sanitary drainage 9%, plumbing vents 7%, traps, interceptors and separators 7% and storm drainage 2%.

Which code books does the Kansas plumber exam use?

The 2018 International Plumbing Code and the 2018 International Fuel Gas Code. Wichita's adopted plumbing code is the UPC, so ask your jurisdiction which exam it accepts.

Does this exam cover gas piping?

Yes. Gas piping is 19% of the exam, drawn from the IFGC.

Free questions with answers

Show all 10 free questions and answers
  1. A permit is issued on March 1, but the crew never starts the permitted work. Under the IPC, the permit becomes null and void if work is not commenced within how many days of the permit date, and what is required before work can then begin?

    Answer: 180 days; a new permit must be obtained before work can resume

    Section 106.5.3: a permit expires if work is not commenced within 180 days of issue, or if work is suspended or abandoned for 180 days after it starts. Before work recommences a new permit must be obtained (at half the fee if the plans are unchanged). It is not automatically renewed, and 365 days is not the period.

    Reference: 2018 International Plumbing Code, 106.5.3

  2. According to Table 604.3, what flow pressure must be available at the fixture supply outlet serving a blow-out type flushometer valve water closet?

    Answer: 45 psi

    Table 604.3 lists the blow-out flushometer valve water closet at 25 gpm and 45 psi. The siphonic flushometer valve closet is 25 gpm at 35 psi, the flushometer tank closet is 1.6 gpm at 20 psi, and a valve urinal is 12 gpm at 25 psi, which are the common look-alike values.

    Reference: 2018 International Plumbing Code, Table 604.3

  3. A 4-inch by 3-inch water closet flange is installed on a 3-inch fixture drain. Under Section 704.2, how is this treated?

    Answer: It is not considered a reduction in size in the direction of flow

    Section 704.2 prohibits reducing drainage pipe size in the direction of flow, but lists a 4-inch by 3-inch water closet flange, a closet bend with a 4-inch inlet and 3-inch outlet (4-inch leg upright and below the flange), and an offset closet flange as not being reductions.

    Reference: 2018 International Plumbing Code, 704.2

  4. Under Section 901.2, the vent system must prevent any fixture trap seal from being subjected to a pressure differential greater than:

    Answer: 1 inch of water column

    Section 901.2 requires a vent system that admits or releases air so that no fixture trap seal is subjected to a pressure differential of more than 1 inch of water column. Larger differentials would blow or siphon the water seal out of the trap, allowing sewer gas into the building.

    Reference: 2018 International Plumbing Code, 901.2

  5. Which of the following traps is prohibited by Section 1002.3?

    Answer: A bell trap on a floor drain

    Section 1002.3 prohibits traps that depend on moving parts for the seal, bell traps, crown-vented traps, S traps, drum traps and certain partition-seal traps. Drum traps used as solids interceptors and drum traps serving chemical waste systems are excepted, and an ordinary P-trap is the standard accepted type.

    Reference: 2018 International Plumbing Code, 1002.3

  6. A water closet is being set next to a side wall. Under Section 405.3.1, what is the minimum distance from the center of the water closet to the side wall?

    Answer: 15 inches

    Section 405.3.1 requires water closets, urinals, lavatories and bidets to be at least 15 inches from their center to any side wall, partition, vanity or other obstruction, and at least 30 inches center to center between adjacent fixtures. The 21-inch figure is the required clearance in front of the fixture, and 12 inches is only for an accessible children's water closet.

    Reference: 2018 International Plumbing Code, 405.3.1

  7. A new bathtub is being roughed in. According to Section 407.2, bathtubs must have a waste outlet and an overflow outlet connected to tubing or piping that is at least what diameter?

    Answer: 1 1/2 inches

    Section 407.2 requires a waste outlet and an overflow, connected to waste tubing or piping not less than 1 1/2 inches in diameter, with a water-tight stopper on the waste outlet. Table 709.1 also lists a 1 1/2-inch minimum trap for a bathtub.

    Reference: 2018 International Plumbing Code, 407.2

  8. A sump pit for a building storm drain is being installed with no special approval. Under Section 1113.1.2, what is the minimum size of the sump pit?

    Answer: 18 inches in diameter and 24 inches in depth

    Section 1113.1.2 requires a sump pit of not less than 18 inches in diameter and not less than 24 inches in depth unless otherwise approved, with access, a solid floor and a removable cover. Discharge piping requires a gate valve and a full-flow check valve, except that one- and two-family dwellings need only a check valve (Section 1113.1.4).

    Reference: 2018 International Plumbing Code, 1113.1.2

  9. Which gas may NOT be used as the medium for pressure testing a new fuel gas piping system under Section 406.2?

    Answer: Oxygen

    Section 406.2 allows air, nitrogen, carbon dioxide or an inert gas as the test medium and states that oxygen shall not be used. Oxygen under pressure can react violently with oil and grease residues in the piping.

    Reference: 2018 International Fuel Gas Code, 406.2

  10. A new gas piping system has a proposed maximum working pressure of 5 psig. According to Section 406.4.1, what is the minimum test pressure?

    Answer: 7.5 psig

    Section 406.4.1 requires a test pressure of at least 1 1/2 times the proposed maximum working pressure, but not less than 3 psig. 1.5 x 5 psig = 7.5 psig. The 3 psig floor applies only to low-pressure systems, where 1.5 times the working pressure would be lower.

    Reference: 2018 International Fuel Gas Code, 406.4.1

Sources

Questions last verified November 4, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.