Requirements at a glance
| Agency | Iowa Plumbing and Mechanical Systems Board (PMSB); exam by Kirkwood Community College |
|---|---|
| Experience | 36 months of DOL apprenticeship (you may test up to 6 months before the 48 months of credit), or 4 years of experience before January 1, 2010 |
| Exam | 75 questions, 3 hours, open book; 75% to pass |
| Books allowed | 2024 Uniform Plumbing Code and the Iowa 2024 plumbing amendment booklet |
| Fees | $119 to Kirkwood plus a $35 PMSB exam-candidate application per exam |
Plumbers applying to the Plumbing and Mechanical Systems Board for a journeyperson plumber license: 36 months of DOL apprenticeship (you may test up to 6 months before the 48 months of credit), or 4 years of experience before January 1, 2010.
Official links
How to get licensed, step by step
Apply to the PMSB
Submit the exam-candidate application and fee to the Plumbing and Mechanical Systems Board for approval.
Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
Register with Kirkwood
Register and pay Kirkwood for your exam, then test at one of about 16 Iowa community-college centers. Fees are non-refundable and non-transferable.
Take the exam
Bring your approved references and a battery-operated, non-programmable calculator. You need 75% to pass.
Apply for your license
After you pass, send the Board a post-examination licensure application. If you fail, register and pay for a new exam (Kirkwood, 319-398-1022).
Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
How to prepare
- Kirkwood's outlines say questions are based on the listed edition, but you may bring any edition. Iowa adopted the 2024 UPC and 2024 IMC with amendments effective March 26, 2025.
- Code books may be bound or loose-leaf. Photocopies, handwritten notes and sticky notes are not allowed; highlighting and permanent tabs are.
- The exam is open book, so tab each chapter and practice finding answers fast.
- Sanitary drainage and vents are 40% of the exam. Drill drain and vent sizing, fixture units, trap arms and slopes against the UPC tables, and check the Iowa amendment booklet for changes.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the UPC and the Iowa amendment booklet. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2024 Uniform Plumbing Code (UPC), IAPMOEssential
Iowa's plumbing code (481 IAC 425) with Iowa amendments, effective March 26, 2025. Fuel gas piping is UPC Chapter 12.
Iowa State Plumbing Code 2024 Amendment BookletEssential
Listed with the UPC in Kirkwood's plumbing references. Download it from the PMSB plumbing licensure page.
Official reference list (as published by the testing agency)
- 2024 Uniform Plumbing Code (UPC), IAPMO
- Iowa State Plumbing Code 2024 Amendment Booklet (Iowa Department of Public Health)
What's on the exam
Official content outline from Kirkwood Community College (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Ch 3 General Regulations | 5 | |
| Ch 4 Fixtures and Fittings | 8 | |
| Ch 5 Water Heaters | 8 | |
| Ch 6 Water Supply and Distribution | 10 | |
| Ch 7 Sanitary Drainage | 20 | |
| Ch 8 Indirect Wastes | 5 | |
| Ch 9 Vents | 20 | |
| Ch 10 Traps and Interceptors | 5 | |
| Ch 11 Storm Drainage | 10 | |
| Ch 12 Fuel Gas Piping | 9 |
The outline totals 100; the other items on the 75-question exam are unscored or unassigned.
Exam day details
- Administered by Kirkwood Community College for the Iowa Plumbing and Mechanical Systems Board (PMSB).
- Fee: $119 to Kirkwood per exam, plus a $35 PMSB exam-candidate application per exam. Exam fees are non-refundable and non-transferable.
- 75 questions in 3 hours (Journeyperson Plumber with Gas); 75% to pass. Fuel gas piping is UPC Chapter 12.
- Iowa adopted the 2024 UPC with amendments (481 IAC 425), effective March 26, 2025.
- Open book: bring the references listed. Code books may be bound or loose-leaf; photocopies are not allowed. You may highlight and add permanent tabs before the exam, but handwritten notes in the books are not allowed and sticky notes are not accepted.
- Exam questions are based on the listed edition, but the books you bring may be any edition.
- You may bring an architect's scale or rule and a battery-operated, non-programmable calculator with no printing capability.
- Kirkwood tests at about 16 Iowa community-college centers. Pass with 75%; then send the PMSB a post-examination licensure application. If you fail you must register and pay for a new exam.
Frequently asked questions
What's on the Iowa journeyperson plumber exam?
75 questions by UPC chapter: sanitary drainage 20%, vents 20%, water supply and distribution 10%, storm drainage 10%, fuel gas piping 9%, fixtures and fittings 8%, water heaters 8%, and general regulations, indirect wastes and traps and interceptors 5% each.
Is the exam open book?
Yes: the 2024 UPC and the Iowa 2024 amendment booklet. Highlighting and permanent tabs are allowed.
What does it cost?
$119 to Kirkwood, plus a $35 PMSB exam-candidate application per exam.
What if I fail?
Register and pay for a new exam through Kirkwood (319-398-1022).
Free questions with answers
Show all 10 free questions and answers
A contractor in Iowa lays 4-inch thermoplastic sewer pipe with a 4.5 inch outside diameter. Under the Iowa amendment to Section 314.4.1, what is the maximum trench width at the base of the pipe?
Answer: 27 inches
Iowa amends Section 314.4.1 to limit trench width for thermoplastic pipe to six times the outside diameter at the base: 6 x 4.5 = 27 inches. Eighteen inches (4 x OD) and 36 inches (8 x OD) use the wrong multiplier, and 22.5 inches is 5 x OD. The pipe must also be bedded in at least 4 inches of aggregate.
Reference: 2024 Uniform Plumbing Code as amended by 481 IAC 425.4, Section 314.4.1
What is the minimum distance from the centerline of a water closet to a side wall or other obstruction?
Answer: 15 inches
Section 402.5 says no water closet or bidet may be set closer than 15 inches center to a side wall or obstruction. Twelve inches is the urinal figure, and 24 inches is the clear space required in front of the fixture.
Reference: 2024 Uniform Plumbing Code, Section 402.5
A helper installs a ball valve on the discharge pipe of a water heater relief valve so the line can be isolated for service. What is the code position?
Answer: It must be removed, because no valve may be placed on the relief valve discharge pipe
Section 504.6 prohibits a shutoff valve between the relief valve and the heater or on the discharge pipe between the relief valve and the atmosphere. Section 608.5 repeats that discharge piping may have no valves, obstructions or means of isolation.
Reference: 2024 Uniform Plumbing Code, Section 504.6 and Section 608.5
In Iowa, what is the minimum depth of earth cover for building supply yard piping?
Answer: 60 inches
The base UPC text of Section 609.1 asks for 12 inches below grade, but Iowa amends it to require building supply yard piping to have not less than 60 inches of earth cover. The 12 inch figure is the unamended trap answer.
Reference: 2024 Uniform Plumbing Code as amended by 481 IAC 425.4, Section 609.1
Section 707.4 allows cleanouts to be omitted on a horizontal drain line shorter than 5 feet, unless the line serves which fixture?
Answer: A sink or a urinal
The first exception to Section 707.4 lets a cleanout be omitted on a horizontal drain under 5 feet long unless it serves sinks or urinals, which can load the line with grease and solids.
Reference: 2024 Uniform Plumbing Code, Section 707.4
A clothes washer standpipe receptor is being roughed in. Which set of dimensions complies with Section 804.1?
Answer: Standpipe rim 24 inches above the trap weir, with the trap 12 inches above the floor
Section 804.1 limits the standpipe to not more than 30 inches and not less than 18 inches above the trap weir, and the trap must be roughed in not less than 6 and not more than 18 inches above the floor, never below the floor.
Reference: 2024 Uniform Plumbing Code, Section 804.1
Using Iowa's replacement Table 1002.2, what is the maximum developed length of a 3-inch trap arm from the trap weir to the vent, other than for water closets?
Answer: 12 feet
Iowa's Table 1002.2 lists the maximum trap arm length by diameter: 1-1/4 inch 5 feet, 1-1/2 inch 6 feet, 2 inch 8 feet, 3 inch 12 feet, 4 inch 12 feet, and over 4 inches 12 feet, with a minimum distance of 2 times the diameter.
Reference: 2024 Uniform Plumbing Code as amended by 481 IAC 425.4, Table 1002.2
The vent system must be designed so that a trap seal is never exposed to more than what pressure differential on the outlet side of the trap?
Answer: 1 inch of water column
Section 901.3 requires the vent system to prevent a trap seal from being exposed to a pressure differential exceeding 1 inch water column on the outlet side. Table 703.2 sizing is based on that requirement.
Reference: 2024 Uniform Plumbing Code, Section 901.3
A 4-inch leader must be checked at a rainfall rate of 2.5 in/h, which is not listed in Table 1103.1. Using the table's note for unlisted rates, what is the maximum roof area?
Answer: 7,360 square feet
Footnote 2 of Table 1103.1 says to divide the 1 in/h area by the desired rainfall rate. A 4-inch leader at 1 in/h handles 18,400 sq ft, and 18,400 / 2.5 = 7,360 sq ft. The 2 in/h column (9,200) overstates the allowance, and the 3 in/h and 4 in/h columns (6,130 and 4,600) understate it.
Reference: 2024 Uniform Plumbing Code, Table 1103.1, Note 2
A new threaded steel gas piping system will carry natural gas at 7 inches water column. What minimum test pressure and duration apply under Section 1213.3?
Answer: 10 psi gauge pressure for at least 15 minutes
Section 1213.3 requires gas piping to stand not less than 10 psi, held for a time the AHJ finds satisfactory but never less than 15 minutes with no perceptible drop. The 60 psi and 30 minute figures apply to welded piping and piping above 14 inches water column.
Reference: 2024 Uniform Plumbing Code, Section 1213.3
Sources
- Kirkwood Community College: Iowa state discipline exams, outlines and references (opens in a new tab)
- Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
- Iowa Administrative Code 481-429 (PMSB licensing and examination rules) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.