Indianapolis Residential Electrician Exam: Practice Test & Licensing Guide

The ICC national Residential Electrician exam (R18-N) the Indianapolis Board of Electrical Examiners can assign for the Residential electrical license: 60 open-book questions on the 2023 NEC, 3 hours, 75% to pass.

Questions
60
Time limit
3 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge

An enclosed panelboard is installed indoors in a dwelling basement. Which statement about lighting its working space agrees with 110.26(D)?

Requirements at a glance

AgencyCity of Indianapolis / Marion County Board of Electrical Examiners; the Board assigns an International Code Council (ICC) exam
LicenseResidential Electrician: one- and two-family structures only
ExamResidential Electrician (ICC national exam): 60 questions, 3 hours, 75%
Books allowed2023 NEC and Ugly's Electrical References (any edition); open book
Edition checkThe city's materials do not name the ICC exam number or NEC edition. Our bank follows ICC's national exam on the 2023 NEC; confirm the exact exam and edition with the Board
Eligibility6 years of electrical construction experience (up to 2 years may be credited for related college courses and up to 2 for a related apprenticeship); notarized employer letter, three customer reference letters; Board interview
RetakesYou may retake the exam, but if you have not passed within 6 months of approval, you wait one year from approval before orientation and licensure
Fees$120 to ICC's testing vendor; City license holder fee $189 to $377 depending on when you apply in the two-year term ($247 renewal)
Bond and insurance$10,000 surety bond, general liability insurance and workers' compensation

Electricians seeking a Residential electrical license in Indianapolis and Marion County, which allows work on one- and two-family structures only.

How to get licensed, step by step

  1. Apply to the Board

    Send the Board of Electrical Examiners your application, experience letters, three customer reference letters and a driver's license copy at least 10 business days before its meeting (second Thursday of each month), then interview with the Board. Questions: (317) 327-8467.

    City of Indianapolis: contractor licenses (opens in a new tab)

  2. Sit for the ICC exam

    If the Board approves you, it assigns the appropriate ICC exam and gives you the information to register. Confirm the exam and NEC edition with the Board.

    ICC: National Contractor/Trades Exam Bulletin (opens in a new tab)

  3. Score 75%

    The Board's 2026 policy sets a passing score of 75% on the 2023 NEC examination. If you already passed, you can submit your ICC score report with your application.

    ICC: National Contractor/Trades Exam Bulletin (opens in a new tab)

  4. Orientation and license

    Reappear before the Board for orientation, then send proof of bond, insurance and workers' compensation with the license application and fees. Licenses expire December 31 of odd-numbered years.

    City of Indianapolis: contractor licenses (opens in a new tab)

How to prepare

  • The exam is open book on the 2023 NEC. Tab the load calculation tables in Chapter 9 and Annex D, Article 220 and the conductor ampacity tables.
  • Ugly's is allowed in any edition; know where its formulas and tables are.
  • Branch circuits (25) and services (22) are almost half the exam; practice dwelling service and feeder load calculations.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2023 EditionEssential

    Allowed in the exam room. Almost every electrical question comes from it.

    NFPA (opens in a new tab)

  • Ugly's Electrical References (any edition)

    Allowed in the exam room. Formulas, conductor and conduit tables, motor data.

    Ugly's (opens in a new tab)

Official reference list (as published by the testing agency)
  • 2023 National Electrical Code, NFPA 70 (open book)
  • Ugly's Electrical References, any edition (open book)

What's on the exam

Official content outline from International Code Council (ICC), assigned by the Indianapolis Board of Electrical Examiners (number of questions per topic):

TopicQuestions
General Knowledge12
Services and Service Equipment22
Feeders13
Branch Circuits and Conductors25
Wiring Methods and Materials13
Equipment and Devices8
Special Occupancies, Equipment, and Conditions7

The outline totals 100; the other items on the 60-question exam are unscored or unassigned.

Exam day details

  • Administered by International Code Council (ICC), assigned by the Indianapolis Board of Electrical Examiners.
  • Fee: $120 to ICC's testing vendor (Pearson). The Indianapolis license holder fee is separate ($189 to $377 depending on when you apply in the two-year term).
  • 60 questions in 3 hours; 75% to pass. Open book.
  • This bank follows ICC's national Residential Electrician exam (R18-N) outline, which is based on the 2023 NEC. The Residential license covers one- and two-family structures only.
  • The Indianapolis Board of Electrical Examiners interviews you first. If it approves you, it assigns "the appropriate International Code Council (ICC) exam" and gives you the information to sit for it. The city's materials do not name the exam number, so this page is built on ICC's national electrician exams and the 2023 NEC; confirm the exact exam and edition with the Board before you register.
  • The Board's 2026 policy sets the passing score at 75% on the 2023 NEC examination and says it adopts the most current NEC edition within 90 days of a new one being announced. Ask the Board which edition applies on your test date.
  • Experience needed to go before the Board: 6 years of electrical construction experience documented by a notarized employer letter (or three letters from supply houses or contractors, with business documents). The Board may credit up to 2 years for related college courses and up to 2 years for a related apprenticeship. You also need three customer reference letters and a copy of your driver's license, submitted at least 10 business days before the meeting (second Thursday of each month).
  • After you pass, you reappear before the Board for orientation, then send proof of a $10,000 surety bond, general liability insurance and workers' compensation with the license application and fees. If you do not pass within 6 months of approval, you wait a year from approval before orientation and licensure. You have 2 years after passing to attend orientation.
  • City fees (2026-2027 term): license holder $377 if you apply January to June 2026, $283 July to December 2026, $189 in 2027; $247 to renew. A business license is also required ($247, $185 or $124 by application date; not charged to sole proprietors). Licenses expire December 31 of odd-numbered years.
  • The Board can reciprocate a license from another area if you passed a Prometric (Block) exam that meets its requirements; contact the Board at (317) 327-8467.

Frequently asked questions

What's on the Indianapolis Residential Electrician exam?

The ICC national Residential Electrician outline: branch circuits and conductors 25%, services and service equipment 22%, feeders 13%, wiring methods and materials 13%, general knowledge 12%, equipment and devices 8% and special occupancies, equipment and conditions 7%.

What can a Residential electrician do in Indianapolis?

Work on one- and two-family structures only. The Master license is unrestricted.

Which exam does the Board assign?

The Board assigns the appropriate ICC exam after approving you. The city does not name the exam number or NEC edition, so confirm both with the Board before registering.

Free questions with answers

Show all 10 free questions and answers
  1. An enclosed panelboard is installed indoors in a dwelling basement. Which statement about lighting its working space agrees with 110.26(D)?

    Answer: No added lighting outlet is needed where an adjacent light source already illuminates the space

    110.26(D) requires illumination for working spaces about indoor service equipment and enclosed panelboards, and automatic means may not control all of it. Additional lighting outlets are not required where the work space is illuminated by an adjacent light source (or by a switched receptacle as permitted by 210.70(A)(1) Exception No. 1). There is no ampere threshold and no rule placing the light directly over the panel.

    Reference: NFPA 70, National Electrical Code, 2023, 110.26(D)

  2. A house has its service disconnect in an outdoor meter-main. A 200-ampere panelboard in the basement is fed from it by a 4-wire feeder (two ungrounded, a neutral and an equipment grounding conductor). Where may the neutral be connected to the basement panelboard enclosure?

    Answer: Not at all; its neutral bar stays isolated from the enclosure

    250.24(B) prohibits connecting the grounded conductor to normally non-current-carrying metal parts, to equipment grounding conductors, or regrounding it on the load side of the service disconnecting means, except as Article 250 otherwise permits. The neutral-to-ground bond belongs at the service; the downstream panel keeps the neutral isolated and bonds the enclosure to the equipment grounding conductor. A ground rod does not change this.

    Reference: NFPA 70, National Electrical Code, 2023, 250.24(B)

  3. A cable TV installer wants to clamp the coaxial drop to a house's service mast because it is the highest point on the roof. What does 230.28 allow?

    Answer: Not permitted; only power service conductors may attach to the mast

    230.28 permits only power service-drop or overhead service conductors to be attached to a service mast. Communications drops must be supported elsewhere; bracing the mast, a clearance below the weatherhead or a bonding clamp does not change this.

    Reference: NFPA 70, National Electrical Code, 2023, 230.28

  4. An existing one-family dwelling has no new air-conditioning or electric space heating planned. The connected loads are 1,500 sq ft at 3 VA/sq ft, 3,000 VA small-appliance, 1,500 VA laundry, an 8,000-VA range and a 4,500-VA water heater. Using the existing-dwelling method, what is the calculated load in amperes at 240 V?

    Answer: About 55.8 A

    220.83(A): total connected = 4,500 + 3,000 + 1,500 + 8,000 + 4,500 = 21,500 VA. Table 220.83(A) takes the first 8 kVA at 100% and the remainder at 40%: 8,000 + (13,500 x 0.40 = 5,400) = 13,400 VA / 240 V = 55.8 A. Using 100% of everything gives 89.6 A.

    Reference: NFPA 70, National Electrical Code, 2023, 220.83(A) and Table 220.83(A)

  5. A dwelling has one electric clothes dryer with a nameplate rating of 4,000 W. What load must be used for the dryer in the feeder or service calculation?

    Answer: 5,000 VA

    220.54 says the dryer load is 5,000 W (VA) or the nameplate rating, whichever is larger. The 4,000-W nameplate is below the 5,000 minimum, so 5,000 VA is used. Demand factors in Table 220.54 apply only when there are five or more dryers.

    Reference: NFPA 70, National Electrical Code, 2023, 220.54

  6. A bedroom has a 20-in.-wide section of wall between two doorways. Is a receptacle required for that 20-in. section under 210.52(A)?

    Answer: No, because a wall space must be 2 ft or more in width

    210.52(A)(2) defines wall space as any space 2 ft (600 mm) or more in width, unbroken along the floor line by doorways, fireplaces and similar openings. A 20-in. section is not a wall space, so it needs no receptacle on its own.

    Reference: NFPA 70, National Electrical Code, 2023, 210.52(A)(2)

  7. Three current-carrying 8 AWG copper THHN conductors run in a hot attic where the ambient temperature is 38 C (100 F). Using the 90 C column of Table 310.16 and Table 310.15(B)(1)(1), what is the corrected ampacity of each conductor, before any termination limits?

    Answer: About 50 A

    8 AWG copper THHN is 55 A in the 90 C column. At 36 to 40 C ambient, the 90 C correction factor is 0.91, so 55 x 0.91 = 50.05 A. No adjustment factor applies for only three conductors. Using the 75 C column (50 x 0.88) gives 44 A, and the 60 C column with the 90 C factor gives 36 A.

    Reference: NFPA 70, National Electrical Code, 2023, Table 310.16 and Table 310.15(B)(1)(1)

  8. A 120-volt, 20-ampere residential branch circuit with GFCI protection runs to a yard light. It will be direct-buried Type UF cable under an open lawn. What is the minimum cover?

    Answer: 12 in.

    Table 300.5, Column 4 allows 12 in. of cover for residential branch circuits rated 120 V or less with GFCI protection and a maximum overcurrent device of 20 A. Without GFCI protection it would be 24 in. (Column 1). Note 4 on the table covers cases that mix columns.

    Reference: NFPA 70, National Electrical Code, 2023, Table 300.5(A), Column 4

  9. A residential in-ground swimming pool is being given its equipotential bonding grid. What conductor does 680.26(B) require to bond the pool shell, perimeter surfaces, metal fittings and equipment together?

    Answer: Solid copper, 8 AWG or larger, insulated, covered or bare

    680.26(B) requires the parts listed in 680.26(B)(1) through (B)(7) to be bonded together with solid copper conductors, insulated, covered or bare, not smaller than 8 AWG (or rigid metal conduit of brass or other identified corrosion-resistant metal). Stranded, aluminum or Table 250.122 sizing does not meet this rule.

    Reference: NFPA 70, National Electrical Code, 2023, 680.26(B)

  10. In a one-family dwelling, which 125-volt, 15- or 20-ampere nonlocking receptacles must be listed tamper-resistant?

    Answer: All of them, including attached and detached garages

    406.12(1) requires all 15- and 20-A, 125- and 250-V nonlocking receptacles in dwelling units, including attached and detached garages and accessory buildings, to be listed tamper-resistant. Exceptions include receptacles more than 5 1/2 ft above the floor and those that are part of a luminaire or appliance.

    Reference: NFPA 70, National Electrical Code, 2023, 406.12