Requirements at a glance
| Agency | Illinois Department of Public Health (IDPH) |
|---|---|
| Experience | Licensed apprentice for 4 years, 2 years of high school and an approved plumbing course |
| Exam | Three parts: Knowledge Assessment, Construction Drawings or Plans, and Practical Application; each scored out of 100 |
| Passing | Average of 75 and at least 61 on each part |
| Fees | $175 (Illinois licensed apprentice) or $225 (Chicago or out-of-state plumbers); not refundable |
Licensed Illinois apprentice plumbers (4 years of apprenticeship, 2 years of high school and an approved plumbing course) applying to IDPH for a plumber license. Our bank covers only the knowledge part, not the drawings or practical parts.
Official links
How to get licensed, step by step
Qualify
Hold an Illinois apprentice license and finish the 4-year apprenticeship and approved plumbing course.
Apply to IDPH
Apply at least 30 days before the exam with the application fee.
IDPH: Plumbing licensing (opens in a new tab)68 Ill. Adm. Code 750.310: plumber examination (opens in a new tab)
Pass all three parts
The knowledge part is based on the Illinois Plumbing Code. Our bank covers this part only.
68 Ill. Adm. Code 750.310: plumber examination (opens in a new tab)
How to prepare
- IDPH does not publish question counts, time or topic weights for the knowledge part; our split follows the Illinois Plumbing Code (77 Ill. Adm. Code 890) subparts.
- Learn drainage, vents and water supply first; they are the largest sections of the code.
- Chicago honours IDPH plumber licenses when the employer holds a Chicago plumbing contractor license. Chicago also has its own plumber exam.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
Illinois Plumbing Code (77 Ill. Adm. Code 890)Essential
IDPH's knowledge assessment is based on the Illinois Plumbing Code, which is its own code, not the IPC or UPC.
Official reference list (as published by the testing agency)
- Illinois Plumbing Code, 77 Ill. Adm. Code 890
- Illinois Plumber License Act (225 ILCS 320) and 68 Ill. Adm. Code 750 (licensing rules)
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Materials | 8 | |
| Joints | 6 | |
| Traps and Cleanouts | 6 | |
| Interceptors | 4 | |
| Fixtures | 8 | |
| Hangers | 4 | |
| Indirect Waste | 4 | |
| Water Supply | 16 | |
| Drainage | 16 | |
| Vents | 12 | |
| Special Venting | 6 | |
| Inspection and Testing | 10 |
Exam day details
- Administered by the Illinois Department of Public Health (IDPH).
- Fee: $175 application fee for an Illinois licensed apprentice plumber; $225 for plumbers registered or licensed in Chicago or outside Illinois. Non-refundable.
- The IDPH exam has three parts: a Knowledge Assessment (true/false, multiple choice or fill-in, based on the Illinois Plumbing Code), Construction Drawings or Plans, and Practical Application.
- Each part is scored out of 100. To pass you need an average of 75 and at least 61 on each part (68 Ill. Adm. Code 750.310).
- Apply to IDPH at least 30 days before the exam. Fees are not refundable.
- IDPH does not publish the number of knowledge questions, the time limit or topic weights, so our length and timer are practice settings only.
- Chicago honours IDPH plumber licenses when the employer holds a Chicago plumbing contractor license.
Note: IDPH does not publish the knowledge part's question count, time limit or topic weights, so the topic split, length and timer in our practice tests are estimates.
Frequently asked questions
How is the Illinois plumber exam scored?
Each of the three parts is scored out of 100. You need an average of 75 and at least 61 on every part.
What book is the Illinois plumber knowledge exam based on?
The Illinois Plumbing Code, 77 Illinois Administrative Code 890. It is Illinois's own code, not the IPC or UPC.
Does this cover the practical exam?
No. Our questions cover the knowledge part only. The drawings and practical parts are separate.
Free questions with answers
Show all 10 free questions and answers
Which set of information must be cast, stamped or indelibly marked on each length of pipe and each fitting used in an Illinois plumbing system?
Answer: Maker's mark or name, weight, type, class of product and the applicable standard
Section 890.210(c) requires each length of pipe, fitting, trap, fixture, device and appurtenance to carry the maker's mark or name, weight, type, class and applicable standard. Installer, job and permit information are not product markings.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.210(c)
Where may grooved-type mechanical couplings be used under Section 890.330?
Answer: In potable water and roof drain piping, but not in waste, soil or vent piping
Section 890.330(f) permits grooved couplings (made per 890.320(p)) in potable water and roof drain piping and prohibits them in waste, soil or vent piping.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.330(f)
A building drain changes direction by 45 degrees at each of three consecutive fittings with no cleanout between them. Why does this violate the Illinois Plumbing Code?
Answer: The fittings between cleanouts total 135 degrees, which is more than the 120 degree limit
Section 890.420(b) requires a cleanout or manhole at each change of direction greater than 60 degrees, and the total of fittings between cleanouts may not exceed 120 degrees. Three 45 degree fittings total 135 degrees, which exceeds 120. Each single 45 degree turn is under the 60 degree trigger.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.420(b)
Which type of grease interceptor is prohibited by the Illinois Plumbing Code?
Answer: Water-cooled grease interceptor
Section 890.510(b) prohibits water cooled grease interceptors. The other choices describe requirements of 890.510(a).
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.510(b)
On a mixing faucet, which side must the hot (or tempered) water supply be connected to?
Answer: The left side of the faucet
Section 890.630(e) requires hot or tempered water on the left side of all mixing and single lever faucets. Cross piping inside the faucet by internal modification is not allowed.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.630(e)
How often must reduced pressure principle backflow assemblies be tested, and by whom, after the initial approval?
Answer: At least annually, by a Cross-Connection Control Device Inspector
Section 890.1130(b) requires RPZ, RPDA, DCA and DCDA assemblies to be tested and approved by a Cross-Connection Control Device Inspector (CCCDI) before initial operation and at least annually thereafter, with records kept at the site.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.1130(b)
What is the minimum size of a gravity building drain under the Illinois Plumbing Code?
Answer: 4 inches
Section 890.1340(b)(1) sets 4 inches as the minimum size of any gravity building drain. The 2 inch figure is the minimum for any drainage piping underground or below a basement (890.1340(b)(4)) and for pressure building drains.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.1340(b)(1)
A venting system must be designed so a fixture trap seal is never subjected to a pneumatic pressure differential greater than what?
Answer: 1 inch of water column
Section 890.1420(a) requires the venting system to limit the pressure differential on any trap seal to no more than a 1-inch water column under normal use.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.1420(a)
How many fixtures of the same type may be vented by one circuit vent on a horizontal branch?
Answer: Two but not more than eight
Section 890.1520(a) allows a circuit vent for a branch to which two but not more than eight of the same type of floor outlets or fixtures are connected in battery; the vent takes off in front of the last fixture. Blowout fixtures are prohibited.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.1520(a)
The water supply system operates at 80 psi. What is the minimum test pressure under Section 890.1930(d)?
Answer: 120 psi, since 1.5 x 80 = 120
Section 890.1930(d) requires a test pressure at least 1-1/2 times the system pressure but at least 100 psi: 1.5 x 80 = 120 psi, which is above 100. Because it exceeds 100 psi, the test must be hydrostatic, held for 15 minutes with potable water.
Reference: Illinois Plumbing Code, 77 Ill. Adm. Code 890, Section 890.1930(d)
Sources
- IDPH: Plumbing (opens in a new tab)
- 68 Ill. Adm. Code 750.310: plumber examination (opens in a new tab)
Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.