Hawaii C-52 Ventilating and Air Conditioning Contractor Exam: Practice Test & Licensing Guide

The PSI trade exam for Hawaii's C-52 ventilating and air conditioning contractor classification: 80 questions on the 2018 IMC, load calculations, controls, ducting, piping and equipment. Closed book.

Questions
80
Time limit
3 hours
Passing score
75%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge and Code Requirements

A gas furnace is installed in an attic and must be reached through a passageway. Under the general IMC rule, what are the minimum passageway height and width, and the maximum length measured along the centerline from the opening to the appliance?

Requirements at a glance

AgencyHawaii Contractors License Board (DCCA PVL); exams by PSI
ExperienceAt least 4 years of supervisory experience (foreman, supervising employee or contractor) in the classification within the past 10 years (HAR 16-77-18); the Board may accept equivalent training or experience
ExamsC-52 Ventilating and Air Conditioning Contractor: 80 questions, 3 hours, 75%, plus the Business and Law exam for new applicants
Books allowedNone; closed book
Fees$80 to PSI per exam ($85 for B and A), plus the Board's application and license fees and required insurance

Qualifiers for a Hawaii C-52 ventilating and air conditioning contractor license from the Contractors License Board, in addition to the Business and Law exam.

How to get licensed, step by step

  1. Apply to the Board

    Send the Contractors License Board your application. You can't register with PSI until the Board approves it and sends a letter of approval.

    Contractors License Board (opens in a new tab)Hawaii Administrative Rules 16-77 (contractors) (opens in a new tab)

  2. Schedule Business and Law and the C-52 exam with PSI

    Register online or call PSI at 833-333-4754. Your approval is good for 6 months and you can test as often as you like in that time. After 6 months you need a new application.

    Schedule with PSI (Hawaii trade exams) (opens in a new tab)

  3. Pass both exams

    Each exam needs 75%. If you already hold a Hawaii license and add a classification, you take only the new trade exam.

    Schedule with PSI (Hawaii trade exams) (opens in a new tab)

  4. Get licensed

    Send the Board your results and proof of the insurance (workers' compensation and liability) the license requires.

    Contractors License Board (opens in a new tab)Hawaii Revised Statutes chapter 444 (contractors) (opens in a new tab)

How to prepare

  • Hawaii's trade exams are PSI exams on specific editions: the 2020 NEC, the 2018 UPC, IMC, IFGC and IBC. Hawaii's state electrical code is older than the 2020 NEC, so study to the editions on PSI's bulletin, and check the bulletin again before test day.
  • Contractor exams are closed book except C-13, where PSI provides the NEC. Electrician exams provide the NEC too. Plumber and other contractor exams allow no reference books.
  • General knowledge and code requirements is 34 of the 80 questions: study the 2018 IMC.
  • Control (10) and equipment (10) draw on Modern Refrigeration and Air Conditioning; load calculations (6) follow ACCA Manual N.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • 2018 International Mechanical Code (IMC), ICCEssential

    On PSI's outline, closed book. Most of the general knowledge and code questions.

  • Modern Refrigeration and Air Conditioning, 21st Edition, Goodheart-Willcox

    On PSI's outline, closed book. Source for controls, equipment and system theory.

    Goodheart-Willcox (opens in a new tab)

  • ACCA Manual N: Commercial Load Calculation for Small Commercial Buildings, 5th Edition (2008)

    On PSI's outline, closed book. Load calculation questions.

  • SMACNA HVAC Duct Construction Standards, Metal and Flexible, 4th Edition (2020)

    On PSI's outline, closed book. Ducting questions.

  • 29 CFR Part 1926 (OSHA construction standards)

    On PSI's outline, closed book. Safety questions.

    Read free (eCFR) (opens in a new tab)

Official reference list (as published by the testing agency)
  • International Mechanical Code (IMC), 2018 edition, ICC (not allowed in the exam room)
  • Modern Refrigeration and Air Conditioning, 21st edition, Goodheart-Wilcox (not allowed)
  • Manual N: Commercial Load Calculation for Small Commercial Buildings, 5th edition, 2008, ACCA (not allowed)
  • HVAC Duct Construction Standards, Metal and Flexible, 4th edition, 2020, SMACNA (not allowed)
  • 29 CFR Part 1926 (OSHA construction standards) (not allowed)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Knowledge and Code Requirements34
Load Calculations6
Control10
Ducting and Insulation8
Piping8
Safety OSHA4
Equipment10

Exam day details

  • Administered by PSI Services for the Hawaii Contractors License Board.
  • Fee: $80 to PSI. The Contractors License Board's application and license fees are separate.
  • 80 scored questions in 3 hours; 60 correct (75%) to pass. The exam is closed book.
  • The Board must approve your application before you can register with PSI. Your eligibility lasts 6 months, and you can test as often as you like within it.
  • PSI may add up to 10 unscored pretest questions; they do not count against your time.
  • Closed-book and open-book rules are on each exam page. PSI provides an online calculator, or you can bring a silent, non-programmable one.

Frequently asked questions

What's on the Hawaii C-52 exam?

80 scored questions: general knowledge and code requirements 34, control 10, equipment 10, ducting and insulation 8, piping 8, load calculations 6 and safety OSHA 4.

Which code edition is on the exam?

The 2018 International Mechanical Code.

Do I also take Business and Law?

Yes, if you are a new applicant.

Free questions with answers

Show all 10 free questions and answers
  1. A gas furnace is installed in an attic and must be reached through a passageway. Under the general IMC rule, what are the minimum passageway height and width, and the maximum length measured along the centerline from the opening to the appliance?

    Answer: 30 inches high, 22 inches wide, not more than 20 feet long

    IMC 306.3: the attic passageway must be at least 30 inches high and 22 inches wide and no more than 20 feet long, with continuous solid flooring at least 24 inches wide. The 50-foot length applies only under the exception when the passageway is at least 6 feet high and 22 inches wide for its entire length.

    Reference: 2018 International Mechanical Code, 306.3

  2. An air handler above a finished ceiling has an auxiliary pan with no separate drain line. Which addition makes that auxiliary protection method code-compliant?

    Answer: A UL 508 water-level detection device that shuts off the equipment before the pan overflows

    IMC 307.2.3 allows an auxiliary pan without a separate drain only where it has a water-level detection device conforming to UL 508 that shuts off the equipment served before the pan overflows. An alarm alone or a second line joining the primary does not meet the section.

    Reference: 2018 International Mechanical Code, 307.2.3

  3. A duct system is designed to operate at 2.5 inches of water column. Which is the lowest standard duct pressure classification that satisfies IMC 603.3?

    Answer: 3 inch w.c.

    IMC 603.3 lists the classifications at positive or negative 0.5, 1, 2, 3, 4, 6 or 10 inches w.c., and the classification must equal or exceed the design pressure. 2 inch is below 2.5, so 3 inch is the lowest compliant class.

    Reference: 2018 International Mechanical Code, 603.3

  4. A 3/4-inch PEX tubing run is hung horizontally in a hydronic radiant system. What is the maximum horizontal support spacing in the IMC table?

    Answer: 32 inches

    IMC Table 305.4 lists PEX tubing 1 inch and smaller at 2 2/3 feet (32 inches) horizontally, and 1 1/4 inches and larger at 4 feet. A 3/4-inch tube is in the smaller group.

    Reference: 2018 International Mechanical Code, Table 305.4

  5. A portable ladder is used to reach an upper landing such as a roof. How far must the side rails extend above the upper landing surface under 29 CFR 1926.1053(b)(1)?

    Answer: At least 3 feet

    29 CFR 1926.1053(b)(1): when a portable ladder is used for access to an upper landing, the side rails extend at least 3 feet above the upper landing surface, or the ladder is secured and a grab rail provided where that extension is not possible.

    Reference: 29 CFR 1926, 1926.1053(b)(1)

  6. A cooling system delivers 1,000 cfm of supply air that is 20 degrees F colder than the room. What is the sensible cooling capacity delivered (Q = 1.08 x cfm x delta T)?

    Answer: 21,600 Btu/h

    General practice: Qs = 1.08 x 1,000 cfm x 20 F = 21,600 Btu/h. Multiplying only cfm by delta T gives 20,000 and ignores the 1.08 air constant; 43,200 doubles the result.

    Reference: General practice, General practice: sensible heat equation Qs = 1.08 x cfm x delta T

  7. What is the maximum control voltage the IMC allows for boiler control and limit circuits?

    Answer: 150 volts nominal, line to line

    IMC 1006.8 limits control voltage to 150 volts nominal line to line. The circuit is supplied from a two-wire grounded branch circuit or an isolation transformer with one secondary conductor grounded. Typical 24-volt thermostat circuits are well within this limit.

    Reference: 2018 International Mechanical Code, 1006.8

  8. What must a boiler low-water cutoff do when the water level falls below the lowest safe water level set by the manufacturer?

    Answer: Automatically stop the combustion operation of the appliance

    IMC 1007.2: low-water cutoff and flow sensing controls must automatically stop combustion when the water level drops below the lowest safe level or when circulation stops. An alarm alone does not meet the section.

    Reference: 2018 International Mechanical Code, 1007.2

  9. Which standard covers the controls and safety devices on a boiler with a fuel input rating of 8,000,000 Btu/h?

    Answer: ASME CSD-1

    IMC 1004.1: controls and safety devices for boilers with inputs of 12,500,000 Btu/h or less must meet ASME CSD-1; above that rating NFPA 85 applies. UL 834 is for packaged electric boilers, not for fuel-fired controls.

    Reference: 2018 International Mechanical Code, 1004.1

  10. What is the minimum unobstructed width of passageways around all sides of a boiler, unless otherwise approved?

    Answer: 18 inches

    IMC 1004.3 requires clearances around boilers to permit inspection, servicing, repair and gauge visibility, with passageways on all sides at least 18 inches wide unless otherwise approved.

    Reference: 2018 International Mechanical Code, 1004.3

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.