The PSI exam for the District of Columbia master electrician license: 100 multiple-choice questions on the 2011 NEC and Ugly's, covering services, branch circuits, wiring methods, motors and special occupancies. Open book, 5 hours.

Questions
100
Time limit
5 hours
Passing score
Not published by District of Columbia

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge and Plan Reading

A branch-circuit panelboard in a commercial building is available at 22,000 amperes at its line terminals. Which statement about the overcurrent devices in the panel is correct under 110.9?

Requirements at a glance

AgencyD.C. Board of Industrial Trades, Department of Licensing and Consumer Protection (DLCP); exam by PSI
Exam100 multiple-choice questions, 5 hours (exam ID 220); Pass score not published; PSI reports PASS or FAIL
Experience8 years (16,000 work hours) plus an NEC code class certificate taken within 2 years (DLCP chart)
BooksOpen book: bound references only, permanent tabs, notes in ink or highlighting in code sections only; no writing during the exam
Fees$52 to PSI per exam; D.C. application and license fees are separate

Electricians applying to the Board of Industrial Trades for a D.C. master electrician license. The DLCP chart lists 8 years (16,000 work hours) of experience and an NEC code class certificate taken within 2 years.

How to get licensed, step by step

  1. Meet the experience requirement

    The DLCP chart lists 8 years (16,000 work hours) of experience, with tax records and employment verification letters, and an NEC code class certificate taken within 2 years.

    D.C. Board of Industrial Trades (DLCP) (opens in a new tab)

  2. Apply to the District

    Submit the online application and fees to the Board of Industrial Trades. Approved candidates receive a notice of eligibility.

    D.C. online license application (opens in a new tab)

  3. Register with PSI

    Register by phone at (855) 557-0616 or online, giving the exam ID and title. Pay the $52 exam fee by credit or debit card when you book.

    Register with PSI: electrician exams (opens in a new tab)PSI: Washington D.C. Candidate Information Bulletin (8/25/2022) (opens in a new tab)

  4. Take the exam

    Bring your listed references and matching ID. You see PASS or FAIL right after the exam. To retest you must reapply with the District first.

    PSI: Washington D.C. Candidate Information Bulletin (8/25/2022) (opens in a new tab)

How to prepare

  • Wiring methods (19%), services (16%) and branch circuits (16%) are the largest areas; tab those NEC articles and Ugly's tables.
  • The PSI bulletin (8/25/2022) lists older editions than the District's adopted 2017 DC Construction Codes (2014 NEC, 2015 ICC codes). Confirm the current reference list with PSI (855-557-0616) or the DLCP before you buy books.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2011 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2011 National Electrical Code (NEC), NFPA 70Essential

    The edition on the PSI bulletin (8/25/2022). The District's adopted code is the 2014 NEC; confirm the current list with PSI or the DLCP.

    NFPA (opens in a new tab)

  • Ugly's Electrical References

    Listed on the PSI bulletin (any edition for the master exam).

Official reference list (as published by the testing agency)
  • 2011 National Electrical Code (NFPA 70)
  • Ugly's Electrical References (any edition)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Knowledge and Plan Reading12
Services and Service Equipment16
Feeders4
Branch Circuits and Conductors16
Wiring Methods and Materials19
Equipment and Devices10
Control Devices3
Motors and Generators8
Special Occupancies, Equipment, and Conditions12

Exam day details

  • Administered by PSI Services for the District of Columbia Board of Industrial Trades (DLCP).
  • Fee: $52 to PSI per computer-based exam. D.C. application and license fees are separate.
  • PSI exam ID 220: 100 multiple-choice questions, open book, 5 hours. The content outline is the PSI bulletin's.
  • The bulletin's electrician references are the 2011 NEC and Ugly's Electrical Reference; the District's adopted construction codes are newer (2014 NEC). Confirm the current list with PSI or the DLCP.
  • The DLCP electrician instructions say licenses expire November 30 of odd-numbered years and that reciprocity is by letter of good standing stating the license was obtained by exam (Virginia for journeyman; Maryland or Virginia for master).
  • You apply to the Board online and pay the application fees first. Approved candidates get a notice of eligibility, then register with PSI at (855) 557-0616 or on PSI's D.C. pages using the exam ID and title.
  • Open book: bring only the references the bulletin lists. They must be bound (original, three-ring binder or stapled); photocopies of copyrighted material are not allowed. Notes in ink or highlighting are allowed in code sections only, and tabs must be permanently attached.
  • You may not write or mark in your references during the exam. PSI gives you a whiteboard, markers and scratch paper. Bring a battery-operated, non-programmable calculator without a printer.
  • Your name on the reservation must match your ID or you cannot test and forfeit the fee. Restroom breaks are limited to 5 minutes and the clock keeps running.
  • You see your result right after the exam. Passing candidates are told PASS with no numeric score; candidates who fail get diagnostic feedback by content area.
  • To retest you must reapply with the District before each attempt. The bulletin recommends allowing time to study before registering again.

Note: The PSI bulletin (updated 8/25/2022) lists the 2011 NEC and the 2012 IPC, IFGC and IMC, while the District's adopted construction codes are the 2017 DC Construction Codes (2014 NEC and 2015 ICC codes with D.C. amendments, effective May 29, 2020). We follow the editions on the bulletin. Confirm the current reference list with PSI (855-557-0616) or the DLCP before you buy books. No pass score is published.

Frequently asked questions

How many questions are on the D.C. master electrician exam?

PSI lists 100 multiple-choice questions in 5 hours (exam ID 220), open book. The biggest areas are Wiring Methods and Materials (19%), Services and Service Equipment (16%), Branch Circuits and Conductors (16%).

What is the passing score?

Neither PSI nor the Board of Industrial Trades publishes a passing score. PSI shows PASS or FAIL right after the exam, with no numeric score for passing candidates and diagnostic feedback for those who fail.

Which code edition does the exam use?

PSI's bulletin lists the 2011 NEC and Ugly's Electrical Reference. The District has since adopted the 2014 NEC in the 2017 DC Construction Codes, so confirm the current reference list with PSI or the DLCP before you buy books.

Free questions with answers

Show all 10 free questions and answers
  1. A branch-circuit panelboard in a commercial building is available at 22,000 amperes at its line terminals. Which statement about the overcurrent devices in the panel is correct under 110.9?

    Answer: Each device must have an interrupting rating not less than 22,000 amperes at the nominal circuit voltage unless the equipment is series rated

    Section 110.9 requires equipment intended to interrupt current at fault levels to have an interrupting rating at nominal circuit voltage at least equal to the current available at the line terminals. Series ratings under 240.86 are a separate permission with their own conditions. The conductor ampere rating has nothing to do with interrupting rating.

    Reference: 2011 National Electrical Code (NFPA 70), 110.9

  2. What is the minimum rating of the service disconnecting means for a one-family dwelling under 230.79(C)?

    Answer: 100 amperes, 3-wire

    Section 230.79(C) requires a one-family dwelling service disconnect rated at least 100 amperes, 3-wire. The 60-ampere minimum in 230.79(D) applies to all other installations.

    Reference: 2011 National Electrical Code (NFPA 70), 230.79(C)

  3. A 4-wire, 3-phase, wye-connected feeder supplies mostly electronic data-processing equipment with nonlinear loads. How does 220.61(C) treat the neutral load for that portion of the load?

    Answer: The 70 percent reduction on the neutral is not permitted for the nonlinear portion

    Section 220.61(C)(2) says a neutral reduction is not permitted for that portion of the load consisting of nonlinear loads supplied from a 4-wire, wye-connected, 3-phase system, because harmonic currents add in the neutral. The neutral is not required to be doubled.

    Reference: 2011 National Electrical Code (NFPA 70), 220.61(C)(2)

  4. A kitchen has a 10 ft wall countertop with no range, sink or other break. Under 210.52(C)(1), what is the maximum distance along the wall line from any point to a receptacle outlet?

    Answer: 24 in.

    Section 210.52(C)(1) requires a receptacle at each wall countertop space 12 in. or wider, placed so that no point along the wall line is more than 24 in. measured horizontally from a receptacle in that space. Six feet is the general wall spacing of 210.52(A) and does not apply to countertops.

    Reference: 2011 National Electrical Code (NFPA 70), 210.52(C)(1)

  5. Type UF cable is direct buried in a lawn at a commercial building, with no concrete or other protection and no GFCI-protected residential circuit exception. What minimum cover does Table 300.5 require?

    Answer: 24 in.

    Table 300.5, Column 1 (direct burial cables) requires 24 in. of cover in all locations not otherwise specified. The 6 in. and 12 in. values apply to rigid metal conduit and to certain GFCI-protected residential or low-voltage landscape circuits, and 18 in. is for nonmetallic raceways or locations under concrete cover.

    Reference: 2011 National Electrical Code (NFPA 70), Table 300.5, Column 1

  6. A rigid metal conduit run is buried in a trench in an open field, outside any building, with no slab or paving over it. What is the minimum cover required by Table 300.5?

    Answer: 6 in.

    Column 2 of Table 300.5 gives 6 in. for rigid metal conduit or intermediate metal conduit in all locations not specified. Direct-buried cables need 24 in., and rigid PVC conduit (Column 3) needs 18 in. Metal conduit is permitted less cover because the steel wall protects the conductors.

    Reference: 2011 National Electrical Code (NFPA 70), Table 300.5, Column 2

  7. What is the maximum height of the center of the grip of a wall switch operating handle, in its highest position, above the floor under 404.8(A)?

    Answer: 6 ft 7 in.

    Section 404.8(A) requires switches and circuit breakers used as switches to be readily accessible and installed so the center of the grip of the operating handle, when in its highest position, is not more than 2.0 m (6 ft 7 in.) above the floor or working platform. Exceptions exist for certain busway switches and for some switches adjacent to motors.

    Reference: 2011 National Electrical Code (NFPA 70), 404.8(A)

  8. A motor disconnecting means must be located in sight from the motor location and driven machinery under 430.102(B). How does Article 100 define in sight from?

    Answer: Visible and not more than 50 ft distant from the other equipment

    Article 100 defines in sight from, within sight from and within sight of to mean that the specified equipment is to be visible and not more than 15 m (50 ft) distant from the other. Both conditions must be met, so 50 ft with an obstruction in between does not qualify. Section 430.102(B) uses this definition for the motor disconnect.

    Reference: 2011 National Electrical Code (NFPA 70), Article 100, Definitions (In Sight From); 430.102(B)

  9. A 10 hp, 230-volt, 3-phase squirrel-cage motor has a nameplate current of 26 A. Table 430.250 lists 28 A for a 10 hp motor at 230 volts. What is the minimum ampacity for the branch-circuit conductors to this single motor under 430.22 and 430.6(A)(1)?

    Answer: 35 A

    Section 430.6(A)(1) requires the Table 430.250 full-load current (28 A) rather than the nameplate (26 A) to size conductors and short-circuit protection. Section 430.22 requires conductors with an ampacity of at least 125 percent of that value: 28 x 1.25 = 35 A. The 32.5 A answer uses the nameplate (26 x 1.25), and 28 A omits the 125 percent factor.

    Reference: 2011 National Electrical Code (NFPA 70), 430.22; 430.6(A)(1); Table 430.250

  10. A permanently installed residential swimming pool requires a 125-volt receptacle for general use. Where must at least one general-purpose receptacle be located relative to the inside wall of the pool, under 680.22(A)(3)?

    Answer: At least 6 ft and not more than 20 ft from the pool wall

    Section 680.22(A)(3) requires at least one 125-volt, 15- or 20-ampere general-purpose receptacle on a general-purpose branch circuit, located not less than 6 ft and not more than 20 ft from the inside wall of the pool and not more than 6 1/2 ft above the floor, platform or grade serving the pool. Receptacles within 20 ft must be GFCI protected under 680.22(A)(4).

    Reference: 2011 National Electrical Code (NFPA 70), 680.22(A)(3)-(4)

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.