District of Columbia licensing exam

District of Columbia Journeyman Electrician Exam: Practice Test & Licensing Guide

The PSI exam for the District of Columbia journeyman electrician license: 80 multiple-choice questions on the 2011 NEC and Ugly's, weighted toward wiring methods and branch circuits. Open book, 4 hours.

Questions
80
Time limit
4 hours
Passing score
Not published by District of Columbia

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge

Under the Article 100 definitions of the 2011 NEC, a load is a continuous load when the maximum current is expected to continue for at least how long?

Requirements at a glance

AgencyD.C. Board of Industrial Trades, Department of Licensing and Consumer Protection (DLCP); exam by PSI
Exam80 multiple-choice questions, 4 hours (exam ID 307); Pass score not published; PSI reports PASS or FAIL
Experience4 years (8,000 work hours) plus an NEC code class certificate taken within 2 years; a nationally certified apprenticeship can waive the exam (DLCP chart)
BooksOpen book: bound references only, permanent tabs, notes in ink or highlighting in code sections only; no writing during the exam
Fees$52 to PSI per exam; D.C. application and license fees are separate

Electricians applying to the Board of Industrial Trades for a D.C. journeyman electrician license. The DLCP chart lists 4 years (8,000 work hours) of experience and an NEC code class certificate taken within 2 years; a nationally certified apprenticeship can waive the exam.

How to get licensed, step by step

  1. Meet the experience requirement

    The DLCP chart lists 4 years (8,000 work hours) of experience, with tax records and employment verification letters, and an NEC code class certificate taken within 2 years.

    D.C. Board of Industrial Trades (DLCP) (opens in a new tab)

  2. Apply to the District

    Submit the online application and fees to the Board of Industrial Trades. Approved candidates receive a notice of eligibility.

    D.C. online license application (opens in a new tab)

  3. Register with PSI

    Register by phone at (855) 557-0616 or online, giving the exam ID and title. Pay the $52 exam fee by credit or debit card when you book.

    Register with PSI: electrician exams (opens in a new tab)PSI: Washington D.C. Candidate Information Bulletin (8/25/2022) (opens in a new tab)

  4. Take the exam

    Bring your listed references and matching ID. You see PASS or FAIL right after the exam. To retest you must reapply with the District first.

    PSI: Washington D.C. Candidate Information Bulletin (8/25/2022) (opens in a new tab)

How to prepare

  • Wiring methods are 26% and branch circuits 19%; practice finding Chapter 3 and Chapter 9 tables quickly.
  • The PSI bulletin (8/25/2022) lists older editions than the District's adopted 2017 DC Construction Codes (2014 NEC, 2015 ICC codes). Confirm the current reference list with PSI (855-557-0616) or the DLCP before you buy books.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2011 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2011 National Electrical Code (NEC), NFPA 70Essential

    The edition on the PSI bulletin (8/25/2022). The District's adopted code is the 2014 NEC; confirm the current list with PSI or the DLCP.

    NFPA (opens in a new tab)

  • Ugly's Electrical References

    Listed on the PSI bulletin (any edition for the master exam).

Official reference list (as published by the testing agency)
  • 2011 National Electrical Code (NFPA 70)
  • Ugly's Electrical Reference

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Knowledge6
Services and Service Equipment11
Feeders4
Branch Circuits and Conductors19
Wiring Methods and Materials26
Equipment and Devices13
Control Devices4
Motors and Generators6
Special Occupancies, Equipment, and Conditions11

The outline totals 100; the other items on the 80-question exam are unscored or unassigned.

Exam day details

  • Administered by PSI Services for the District of Columbia Board of Industrial Trades (DLCP).
  • Fee: $52 to PSI per computer-based exam. D.C. application and license fees are separate.
  • PSI exam ID 307: 80 multiple-choice questions, open book, 4 hours. The content outline is the PSI bulletin's.
  • The bulletin's electrician references are the 2011 NEC and Ugly's Electrical Reference; the District's adopted construction codes are newer (2014 NEC). Confirm the current list with PSI or the DLCP.
  • The DLCP electrician instructions say licenses expire November 30 of odd-numbered years and that reciprocity is by letter of good standing stating the license was obtained by exam (Virginia for journeyman; Maryland or Virginia for master).
  • You apply to the Board online and pay the application fees first. Approved candidates get a notice of eligibility, then register with PSI at (855) 557-0616 or on PSI's D.C. pages using the exam ID and title.
  • Open book: bring only the references the bulletin lists. They must be bound (original, three-ring binder or stapled); photocopies of copyrighted material are not allowed. Notes in ink or highlighting are allowed in code sections only, and tabs must be permanently attached.
  • You may not write or mark in your references during the exam. PSI gives you a whiteboard, markers and scratch paper. Bring a battery-operated, non-programmable calculator without a printer.
  • Your name on the reservation must match your ID or you cannot test and forfeit the fee. Restroom breaks are limited to 5 minutes and the clock keeps running.
  • You see your result right after the exam. Passing candidates are told PASS with no numeric score; candidates who fail get diagnostic feedback by content area.
  • To retest you must reapply with the District before each attempt. The bulletin recommends allowing time to study before registering again.

Note: The PSI bulletin (updated 8/25/2022) lists the 2011 NEC and the 2012 IPC, IFGC and IMC, while the District's adopted construction codes are the 2017 DC Construction Codes (2014 NEC and 2015 ICC codes with D.C. amendments, effective May 29, 2020). We follow the editions on the bulletin. Confirm the current reference list with PSI (855-557-0616) or the DLCP before you buy books. No pass score is published.

Frequently asked questions

How many questions are on the D.C. journeyman electrician exam?

PSI lists 80 multiple-choice questions in 4 hours (exam ID 307), open book. The biggest areas are Wiring Methods and Materials (26%), Branch Circuits and Conductors (19%), Equipment and Devices (13%).

What is the passing score?

Neither PSI nor the Board of Industrial Trades publishes a passing score. PSI shows PASS or FAIL right after the exam, with no numeric score for passing candidates and diagnostic feedback for those who fail.

Which code edition does the exam use?

PSI's bulletin lists the 2011 NEC and Ugly's Electrical Reference. The District has since adopted the 2014 NEC in the 2017 DC Construction Codes, so confirm the current reference list with PSI or the DLCP before you buy books.

Free questions with answers

Show all 10 free questions and answers
  1. Under the Article 100 definitions of the 2011 NEC, a load is a continuous load when the maximum current is expected to continue for at least how long?

    Answer: 3 hours or more

    Article 100 defines a continuous load as one where the maximum current is expected to continue for 3 hours or more. This matters because branch-circuit, feeder and service sizing add 125 percent of continuous loads (210.19(A)(1), 215.2(A)(1), 230.42(A)(1)). One or two hours is too short to qualify.

    Reference: 2011 NEC, Article 100, Continuous Load

  2. A store service must carry 80 amperes of continuous load and 40 amperes of noncontinuous load, and the overcurrent device is not listed for 100 percent operation. What is the minimum ampacity of the service-entrance conductors before adjustment or correction factors?

    Answer: 140 amperes

    230.42(A)(1) requires the noncontinuous load plus 125 percent of the continuous load. 80 x 1.25 = 100 A, and 100 + 40 = 140 A. Adding the loads at 100 percent gives 120 A, and applying 125 percent to everything gives 150 A.

    Reference: 2011 NEC, 230.42(A)(1)

  3. A 3-wire, single-phase feeder has a calculated maximum neutral unbalanced load of 300 amperes, with no nonlinear loads. Using the permitted neutral demand reduction, what neutral load can the neutral be sized for?

    Answer: 270 amperes

    220.61(B)(2) allows a 70 percent demand factor on the portion of the unbalanced load over 200 A for a 3-wire single-phase system. The excess is 300 - 200 = 100 A, and 100 x 0.70 = 70 A, so the neutral load is 200 + 70 = 270 A. Applying 70 percent to the full 300 A gives 210 A, which is wrong.

    Reference: 2011 NEC, 220.61(B)(2)

  4. What is the minimum number of small-appliance branch circuits required for the kitchen, pantry, breakfast room and dining room receptacles of a dwelling unit?

    Answer: Two 20-ampere circuits

    210.11(C)(1) requires at least two 20-ampere small-appliance branch circuits for the receptacle outlets in the kitchen, pantry, breakfast room, dining room and similar areas. These circuits are also the basis for the 1500 VA each load in 220.52(A).

    Reference: 2011 NEC, 210.11(C)(1)

  5. Type NM cable run along framing members must be secured at what maximum interval, and how close to each outlet box?

    Answer: Every 4 1/2 ft and within 12 in. of the box

    334.30 requires NM cable to be supported and secured by staples, straps or similar fittings at intervals not exceeding 4 1/2 ft and within 12 in. of every outlet box, junction box, cabinet or fitting. The 6 ft interval belongs to Type MC cable (330.30), and the 3 ft distance applies to raceways such as EMT.

    Reference: 2011 NEC, 334.30

  6. A run of Type MC cable containing three 12 AWG conductors is installed on a wall. What are the securing requirements?

    Answer: Secured at intervals not over 6 ft and within 12 in. of each box

    330.30(B) requires MC cable to be secured at intervals not exceeding 6 ft, and cables containing four or fewer conductors no larger than 10 AWG must also be secured within 12 in. of every box, cabinet, fitting or other termination. The 4 1/2 ft interval is for NM cable, and the 10 ft/3 ft pattern is for rigid and EMT raceways.

    Reference: 2011 NEC, 330.30(B)

  7. In a dwelling unit, which nonlocking 125-volt, 15-ampere receptacle in an area covered by 210.52 is NOT required to be tamper-resistant?

    Answer: One mounted 6 ft above the floor

    406.12 requires listed tamper-resistant receptacles in all areas specified in 210.52. Exceptions include receptacles more than 5 1/2 ft above the floor, receptacles that are part of a luminaire or appliance, and those behind a refrigerator or freezer that are not readily accessible.

    Reference: 2011 NEC, 406.12

  8. What is the minimum ampacity of branch-circuit conductors supplying a continuous-duty 10 hp, 460-volt, three-phase squirrel-cage motor, using the NEC full-load current table?

    Answer: 17.5 amperes

    430.6(A)(1) requires Table 430.250 to be used, not the nameplate: a 10 hp, 460-volt motor is 14 A. 430.22 requires conductor ampacity of at least 125 percent of that value: 14 x 1.25 = 17.5 A. 14 A omits the 125 percent factor, and 16.1 A wrongly uses 115 percent.

    Reference: 2011 NEC, 430.22 and Table 430.250

  9. A 25 hp, 230-volt, three-phase motor (68 A from Table 430.250) uses a fused-switch disconnecting means that is not a listed motor-circuit switch rated in horsepower. What is the minimum ampere rating of the disconnect?

    Answer: 78.2 amperes

    430.110(A) requires the disconnecting means ampere rating to be at least 115 percent of the motor full-load current: 68 x 1.15 = 78.2 A. 85 A is the 125 percent conductor sizing rule from 430.22, not the disconnect rule.

    Reference: 2011 NEC, 430.110(A)

  10. For a new outdoor pool installation, how high must luminaires installed above the pool, or within 5 ft horizontally of its inside walls, be above the maximum water level?

    Answer: 12 ft

    680.22(B)(1) requires luminaires, lighting outlets and ceiling-suspended fans in new outdoor pool areas, over the pool or within 5 ft horizontally of the inside walls, to be at least 12 ft (3.7 m) above the maximum water level. The 7 ft 6 in. height applies only to certain GFCI-protected totally enclosed fixtures in indoor pool areas.

    Reference: 2011 NEC, 680.22(B)(1)

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.