Delaware licensing exam

Delaware Master HVACR Exam: Practice Test & Licensing Guide

The Prov exam for Delaware's master HVACR license: 100 questions on piping, equipment, system sizing and installation, ventilation and exhaust, and testing and inspection. Open book, 70% to pass.

Questions
100
Time limit
4 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Ventilation and Exhaust Systems

Smoke detectors must be installed in the return air system of an air distribution system whose design capacity is greater than what airflow?

Requirements at a glance

AgencyDelaware Division of Professional Regulation, Board of Plumbing, HVACR Examiners; exams by Prov
ExperienceMaster plumber (24 Del.C. 1808): a journeyman certificate from an approved apprenticeship plus 2 years of plumbing under a master plumber, or 7 years under a master plumber plus the Board-approved apprenticeship equivalency test given by a Delaware vo-tech school. Master HVACR requirements are in 24 DE Admin Code 1800; confirm them with DPR.
ExamMaster HVACR exam: 100 questions, 4 hours, 70%
Books allowedIMC and IFGC (2018 per the 3/2022 bulletin), ACCA Duct Slide Rule, Advanced Mechanical Study Guide, Low Pressure Boilers, Manual J Abridged
Fees$100 to Prov per exam (2022 bulletin); DPR application and license fees are separate

HVACR contractors applying to the Delaware Board of Plumbing, HVACR Examiners for a master HVACR license covering heating, air conditioning, refrigeration, ventilation and gas piping.

How to get licensed, step by step

  1. Apply to DPR

    Create an account in the DELPROS portal and submit your application. The Board approves it before you can test.

    Delaware DPR: Board of Plumbing, HVACR Examiners, examinations (opens in a new tab)

  2. Get your bulletin

    Prov emails the candidate information bulletin, usually within 1 to 2 weeks. It lists the books and editions for your test date.

    Prov, Inc. (Delaware exams) (opens in a new tab)

  3. Pass the exam with Prov

    Schedule at a Delaware test site or from home with remote proctoring. You get three attempts before eligibility expires; after that you wait a year and reapply.

    Prov, Inc. (Delaware exams) (opens in a new tab)

  4. Get licensed

    Send DPR your result and license fee. Licenses renew every 2 years (24 Del.C. 1812); Delaware's Business First Steps guide lists the expiration as October 31 of even-numbered years.

    Delaware DPR: Board of Plumbing, HVACR Examiners, examinations (opens in a new tab)Delaware Code Title 24, Chapter 18 (Plumbers and HVACR) (opens in a new tab)

How to prepare

  • Open book: bring the titles Prov lists (older or newer editions are allowed). Permanent tabs are fine; sticky notes and handwritten notes are not. Use a simple 4-function calculator.
  • The Board adopts the 2015 IMC and IFGC as amended. The 3/2022 Prov bulletin lists the 2018 editions, so confirm the editions in the bulletin Prov sends you.
  • General knowledge is 28 of 100 questions: refrigeration cycle, psychrometrics, electrical basics for controls and safety.
  • Equipment (18) and system sizing and installation (18) come next; learn Manual J load basics and duct sizing.
  • Ventilation and exhaust (14), piping (12) and testing and inspection (10) are mostly IMC and IFGC chapters.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • International Mechanical Code (IMC), 2018 edition per the bulletin (Delaware adopts the 2015 IMC as amended)Essential

    Allowed in the exam room. Ventilation, exhaust, ducts, equipment installation and refrigeration.

    ICC store (opens in a new tab)

  • International Fuel Gas Code (IFGC), 2018 edition per the bulletin

    Allowed in the exam room. Gas piping sizing, appliance venting and combustion air.

    ICC store (opens in a new tab)

  • ACCA Duct Slide Rule; Advanced Mechanical Study Guide, 2nd Edition; Low Pressure Boilers, 5th Edition; Manual J Abridged Edition, 8th Edition

    All listed in the 3/2022 bulletin for the master HVACR exam. Sizing, duct design and boiler basics.

    Prov bookstore (opens in a new tab)

Official reference list (as published by the testing agency)
  • International Mechanical Code (IMC), 2018 edition per the 3/2022 bulletin (Delaware adopts the 2015 IMC as amended; see the edition note)
  • International Fuel Gas Code (IFGC), 2018 edition per the 3/2022 bulletin
  • ACCA Duct Slide Rule; Advanced Mechanical Study Guide, 2nd Edition; Low Pressure Boilers, 5th Edition; Manual J Abridged Edition, 8th Edition (all listed in the 3/2022 bulletin)

What's on the exam

Official content outline from Prov, Inc. (number of questions per topic):

TopicQuestions
General Knowledge28
Piping12
Equipment18
System sizing and installation18
Ventilation and Exhaust Systems14
Testing and Inspection10

Exam day details

  • Administered by Prov, Inc. for the Delaware Division of Professional Regulation.
  • Fee: $100 to Prov per exam (2022 bulletin). DPR application and license fees are separate.
  • 100 questions in 4 hours; 70% to pass (per DPR).
  • Master HVACR applicants need a journeyman certificate plus 2 years after apprenticeship under a licensee, or 7 years of experience with the bypass exam, and a CFC card (24 DE Admin Code 1800).
  • Open book: bring the exact titles Prov lists (older or newer editions are allowed). Permanent tabs are fine; repositionable tabs and sticky notes are not. Highlighting and underlining in pen are allowed, but handwritten notes, added formula sheets and stickers are not, and you may not mark your books during the test.
  • Computer-based at Prov's Delaware test sites or at home with remote proctoring (Examroom). Use a simple 4-function calculator; no special calculators.
  • Question counts and times are totals from the Prov bulletin (3/2022). The pass score comes from DPR's exam pages, not the bulletin. Prov emails the current bulletin after DPR approves your application, so use that copy for your test date.
  • Change or cancel at least 3 business days before your test date to keep your fee. After a failure you can retest after 7 days.
  • Plumbing and HVACR candidates get three testing attempts before the application's eligibility expires. After three failures you wait one year and reapply.

Note: Delaware's Board adopts the 2015 IMC and IFGC as amended (24 DE Admin Code 1800). The Prov bulletin we could obtain (3/2022) lists the 2018 editions. Confirm the editions in the bulletin Prov sends you; our questions follow the codes in force in Delaware and stick to material that is stable across editions.

Frequently asked questions

What's on the Delaware master HVACR exam?

100 questions per the Prov bulletin: general knowledge 28, equipment 18, system sizing and installation 18, ventilation and exhaust systems 14, piping 12 and testing and inspection 10.

How long is the Delaware master HVACR exam?

4 hours for 100 questions, open book, with 70% to pass per DPR.

Which mechanical code does Delaware use?

The Board adopts the 2015 IMC and IFGC as amended. The 3/2022 Prov bulletin lists the 2018 editions, so confirm the edition in the bulletin Prov sends you.

Free questions with answers

Show all 10 free questions and answers
  1. Smoke detectors must be installed in the return air system of an air distribution system whose design capacity is greater than what airflow?

    Answer: 2,000 cfm

    IMC 606.2.1 requires smoke detectors in the return air duct or plenum, upstream of filters, exhaust and outdoor air connections, when the return system's design capacity exceeds 2,000 cfm. The same 2,000 cfm threshold applies to combined supply and return systems in 606.2.2.

    Reference: 2015 International Mechanical Code, 606.2.1

  2. An environmental air exhaust duct (not parking garage or transformer vault exhaust) terminates outdoors. Which set of minimum separations does IMC 501.3.1 require?

    Answer: 3 feet from property lines, 3 feet from operable openings (other than Group U), and 10 feet from a mechanical air intake

    For environmental air exhaust, 501.3.1 item 3 requires 3 feet from property lines, 3 feet from operable openings into the building for occupancies other than Group U, and 10 feet from a mechanical air intake. The larger distances in the distractors belong to the product-conveying and flammable-vapor outlet categories.

    Reference: 2015 International Mechanical Code, 501.3.1

  3. A gas-fired water heater is installed in a private garage. What is the minimum height of the burner ignition source above the floor, unless the appliance is listed as flammable vapor ignition resistant?

    Answer: 18 inches

    IMC 304.3 requires appliances with an ignition source in garages to be elevated so the ignition source is at least 18 inches above the floor the appliance rests on. The exception covers appliances listed as flammable vapor ignition resistant.

    Reference: 2015 International Mechanical Code, 304.3

  4. An auxiliary drain pan is used as the secondary protection under an attic evaporator coil. Which dimensions satisfy the IMC?

    Answer: At least 1 1/2 inches deep and at least 3 inches larger than the coil in width and length

    Section 307.2.3 requires the auxiliary pan to have a minimum depth of 1 1/2 inches, to be at least 3 inches larger than the unit or coil in width and length, and to be of corrosion-resistant material, with its own drain discharging to a conspicuous point.

    Reference: 2015 International Mechanical Code, 307.2.3

  5. What is the minimum pressure test duration for a gas piping system in a single-family dwelling under the IFGC?

    Answer: 10 minutes

    Section 406.4.2 sets the duration at 1/2 hour per 500 cu ft of pipe volume, but not less than 10 minutes for a system with a volume under 10 cu ft or a system in a single-family dwelling. The test is never required to exceed 24 hours.

    Reference: 2015 International Fuel Gas Code, 406.4.2

  6. What is the minimum burial depth for underground fuel gas piping under IFGC 404.12, and what depth is allowed for an individual line to an outdoor grill?

    Answer: 12 inches generally, and 8 inches for individual outdoor appliance lines

    Section 404.12 requires underground piping at least 12 inches below grade. Section 404.12.1 allows individual lines to outdoor lights, grills and other appliances to be at least 8 inches below finished grade where approved and not subject to physical damage.

    Reference: 2015 International Fuel Gas Code, 404.12, 404.12.1

  7. A utility room contains an 80,000 Btu/h furnace and a 40,000 Btu/h water heater, and all combustion air is taken from inside the building. Using the standard method, what minimum room volume is required?

    Answer: 6,000 cubic feet

    IFGC 304.5.1 requires 50 cubic feet per 1,000 Btu/h of appliance input, summed for all appliances in the space. 80,000 + 40,000 = 120,000 Btu/h; 120 x 50 = 6,000 cu ft. Leaving out the water heater gives 4,000 cu ft, and using 20 cu ft per 1,000 Btu/h gives 2,400.

    Reference: 2015 International Fuel Gas Code, 304.5.1

  8. An enclosure holds 120,000 Btu/h of gas appliances with combustion air from outdoors through two permanent openings that connect directly to the outdoors. What is the minimum free area of each opening under the two-permanent-openings method?

    Answer: 30 square inches

    IFGC 304.6.1 requires 1 square inch per 4,000 Btu/h for each opening when directly communicating with the outdoors or through vertical ducts. 120,000 / 4,000 = 30 sq in each. Using 2,000 Btu/h per sq in (horizontal ducts) gives 60 sq in, and 1,000 per sq in gives 120.

    Reference: 2015 International Fuel Gas Code, 304.6.1

  9. Which substitute is exempt from the venting prohibition in any application under 40 CFR 82.154(a)(1)?

    Answer: Carbon dioxide

    Section 82.154(a)(1) exempts carbon dioxide and nitrogen in any application, water in any application, and certain other substitutes only in specific end-uses (ammonia in commercial or industrial process refrigeration or absorption units; hydrocarbons in industrial process refrigeration).

    Reference: 40 CFR Part 82, Subpart F, 40 CFR 82.154(a)(1)

  10. Which refrigerant pressure class is defined as using a refrigerant with a liquid-phase saturation pressure below 45 psia at 104 degrees F (examples include R-11 and R-123)?

    Answer: Low-pressure appliance

    Section 82.152 defines a low-pressure appliance as one using a refrigerant with a saturation pressure below 45 psia at 104 F. Medium-pressure appliances fall between 45 and 170 psia (for example R-134a and R-12), and Type III technicians service low-pressure appliances.

    Reference: 40 CFR Part 82, Subpart F, 40 CFR 82.152

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.