Requirements at a glance
| Agency | Arkansas Department of Health, State Committee of Plumbing Examiners; the Department gives the exam itself |
|---|---|
| Experience | At least 5 years of experience or the equivalent |
| Exam | Master plumber: four sections in 4 hours (drawings, fixture spacing and sizing, 50 code questions, vents and combustion air, gas pipe sizing) |
| Books allowed | Not stated in the study guide we saw; confirm with the Department of Health |
| Fees | $125 application fee; $50 retest fee for each failed portion |
Plumbers applying to the State Committee of Plumbing Examiners for a master license, with at least 5 years of experience or the equivalent.
Official links
How to get licensed, step by step
Check the exam calendar
The Department of Health gives the exam on set dates each year. Find the next date and the application deadline on its plumbing page.
Apply
Send the application, the $125 fee and proof of experience to the State Committee of Plumbing Examiners.
Study the Department's guide
The Department publishes a study guide for each license that shows how the four sections are laid out: drawings and sizing, 50 code questions, gas piping and venting. Work its sample problems.
Retest what you missed
A retest is $50 for each failed portion, so you do not repeat sections you passed.
How to prepare
- The code questions come from the 2018 Arkansas Plumbing Code, the 2018 Arkansas Fuel Gas Code and the Arkansas State Plumbing Law. Use the Arkansas versions, which carry the state amendments.
- The exam is four hours with four sections that are not timed individually. Do the drawing and sizing sections carefully first; they take the longest.
- Practice water system sizing with 2018 APC Appendix E and gas pipe sizing with the Fuel Gas Code longest-length method (Appendix A).
- Master only: fixture spacing for a given room, plus vent, combustion air and ventilation air sizing in the gas sections.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 Arkansas Plumbing Code and the 2018 Arkansas Fuel Gas Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 Arkansas Plumbing Code (2018 IPC with Arkansas amendments)Essential
The code section and sizing sections come from this book, including Appendix E.
2018 Arkansas Fuel Gas Code (2018 IFGC with Arkansas amendments)Essential
Gas piping, venting and combustion air: Chapter 5 and Chapter 3, and the Appendix A sizing tables.
Official reference list (as published by the testing agency)
- 2018 Arkansas Plumbing Code (2018 International Plumbing Code with Arkansas amendments), including Appendix E
- 2018 Arkansas Fuel Gas Code (2018 International Fuel Gas Code with Arkansas amendments)
- Arkansas State Plumbing Law
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Plumbing Law and Administration | 6 | |
| Fixtures and Water Supply | 10 | |
| Drainage, Waste and Vents | 12 | |
| Water System Sizing (Appendix E) | 4 | |
| Fuel Gas Piping and Appliances | 10 | |
| Venting and Combustion Air | 8 |
Exam day details
- Administered by Arkansas Department of Health, State Committee of Plumbing Examiners.
- Fee: $125 application fee; $50 retest fee for each failed portion.
- Our practice exam uses the 50-question code format and a 2-hour timer; the real exam is four hours across four sections.
- The Department of Health gives this exam itself on set calendar dates, not through Prov or PSI. The exam is four hours in total across four sections.
- The code section is 50 random questions from the 2018 Arkansas Plumbing Code, the 2018 Arkansas Fuel Gas Code and the Arkansas State Plumbing Law.
- Application fee: $125 for a master, $75 for a journeyman. A retest costs $50 per failed portion.
- Pass score is not printed in the study guide; see the note on this page.
Note: The Department of Health's study guides do not print the pass score or give the weight of each section, so the pass score (70% assumed) and topic split are unverified. Only the 50 code questions and the sizing calculations fit multiple choice; the drawing sections are not practiced here.
Frequently asked questions
What's on the Arkansas master plumber exam?
Four sections: a drainage riser drawing with water system sizing and fixture spacing in a given room, 50 random code questions, vents with combustion and ventilation air, and gas pipe sizing.
Which code books does it use?
The 2018 Arkansas Plumbing Code (2018 IPC with Arkansas amendments), the 2018 Arkansas Fuel Gas Code and the Arkansas State Plumbing Law.
How much experience does a master plumber need?
At least 5 years of experience or the equivalent, approved by the State Committee of Plumbing Examiners.
Free questions with answers
Show all 10 free questions and answers
A plumber passes the Journeyman examination and is licensed. Under the licensing rules, when is that person normally eligible to take the Master Plumber examination?
Answer: After holding the Journeyman license for one full year
Section II(a)(vi) requires a newly licensed Journeyman to hold that license one full year before becoming eligible for the Master examination. The State Committee of Plumbing Examiners may waive the year in whole or in part only in cases of extreme hardship.
Reference: Arkansas Rules Pertaining to Master, Journeyman, and Restricted Plumber Licenses, Section II(a)(vi)
Under the plumbing code, what is the minimum distance from the centerline of a water closet to a side wall or partition?
Answer: 15 inches
Section 405.3.1 requires 15 inches from the fixture centerline to any side wall, partition, vanity or other obstruction. The 21-inch figure is the required clearance in front of the fixture, and 12 inches applies only to an accessible children's water closet.
Reference: 2018 Arkansas Plumbing Code, Section 405.3.1
A restaurant has a design occupant load of 240. Assume an even split of men and women and use Table 403.1 and Section 403.1.1. How many water closets must be provided for the women's facility?
Answer: 2
Section 403.1.1 halves the load: 240 / 2 = 120 women. Restaurants require 1 water closet per 75 persons: 120 / 75 = 1.6, and fractions round up to 2. Using the 240 total without halving gives 3.2, which would round to 4 and is wrong; dropping the fraction gives 1.
Reference: 2018 Arkansas Plumbing Code, Table 403.1 and Section 403.1.1
A 40-foot horizontal run of 2-inch fixture drain is laid at the minimum slope allowed by Table 704.1. How much total drop does the run need from one end to the other?
Answer: 10 inches
A 2-inch pipe needs 1/4 inch per foot: 40 ft x 0.25 in/ft = 10 inches. 1/8 inch per foot would give 5 inches, 1/2 inch would give 20, and 1/16 inch would give 2 1/2; none of those match the 2-inch row in Table 704.1.
Reference: 2018 Arkansas Plumbing Code, Table 704.1
Using Table 710.1(1), what is the maximum number of drainage fixture units that a 4-inch building drain laid at 1/8 inch per foot can carry?
Answer: 180
Table 710.1(1), 4-inch row: 180 dfu at 1/8 inch per foot, 216 at 1/4 inch per foot and 250 at 1/2 inch per foot. The 160 figure is from Table 710.1(2) for a 4-inch horizontal fixture branch, a different table.
Reference: 2018 Arkansas Plumbing Code, Table 710.1(1)
In the same building and using Table 402.4(2) at the same 80-foot longest length, what is the minimum size of the 12-foot branch that serves only the 50,000 Btu/h water heater (1,000 Btu per cubic foot)?
Answer: 1/2 inch
The branch load is 50 cfh. Under Section 402.4.1 the 80-ft row applies: 1/2 inch carries 56 cfh, which is at least 50 cfh, so 1/2 inch is the minimum. Using the 12-ft branch length would show a much larger capacity but is not permitted, and 3/4 inch or larger is not required.
Reference: 2018 Arkansas Fuel Gas Code, Section 402.4.1 and Table 402.4(2)
Which set of design conditions is the basis of Table 402.4(2)?
Answer: Natural gas, inlet pressure less than 2 psi, 0.5 in. w.c. pressure drop, 0.60 specific gravity
The header of Table 402.4(2) gives natural gas, inlet pressure less than 2 psi, 0.5 in. w.c. drop and 0.60 specific gravity. The 2.0 psi / 1.0 psi table is 402.4(5) and the 5.0 psi / 3.5 psi table is 402.4(7). Always check the header before sizing.
Reference: 2018 Arkansas Fuel Gas Code, Table 402.4(2)
Two natural-draft appliances, a 90,000 Btu/h boiler and a 50,000 Btu/h water heater, share a mechanical room that will use the standard method for indoor combustion air. What minimum room volume does Section 304.5.1 require?
Answer: 7,000 cubic feet
Section 304.5.1: 50 cubic feet per 1,000 Btu/h of total input. 90,000 + 50,000 = 140,000 Btu/h, and 140 x 50 = 7,000 cubic feet. The 2,800 figure uses 20 cubic feet per 1,000 Btu/h, and 3,500 uses 25.
Reference: 2018 Arkansas Fuel Gas Code, Section 304.5.1
A furnace and water heater totaling 60,000 Btu/h take all their combustion air from an adjoining space on the same story, through two openings. What is the minimum free area of each opening under Section 304.5.3.1?
Answer: 100 square inches
Section 304.5.3.1 requires 1 square inch per 1,000 Btu/h, but not less than 100 square inches. 60,000 Btu/h gives 60 square inches, so the 100-square-inch minimum controls. One opening starts within 12 inches of the top, one within 12 inches of the bottom, and the smallest dimension is 3 inches.
Reference: 2018 Arkansas Fuel Gas Code, Section 304.5.3.1
Water pressure drops about 0.433 psi for every foot the water is lifted. A fixture is located 40 feet above the water meter. How much pressure is lost to elevation alone?
Answer: About 17.3 psi
Static head loss = elevation x 0.433 psi per foot = 40 x 0.433 = 17.3 psi (equivalent to 2.31 feet of water per psi). Using 1 psi per foot would give 40 psi, and dividing by 0.433 gives 92.4 psi, neither of which is the standard conversion. This elevation loss is subtracted from meter pressure before any pipe friction is allowed, as part of designing to Section 604.3.
Reference: 2018 Arkansas Plumbing Code, Section 604.3 (design to peak-demand pressure) and Table 604.3
Sources
Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.