Requirements at a glance
| Agency | Arkansas Department of Health, State Committee of Plumbing Examiners; the Department gives the exam itself |
|---|---|
| Experience | At least 4 years of experience or the equivalent |
| Exam | Journeyman plumber: four sections in 4 hours (drawings and sizing, 50 code questions, gas pipe, code illustrations) |
| Books allowed | Not stated in the study guide we saw; confirm with the Department of Health |
| Fees | $75 application fee; $50 retest fee for each failed portion |
Plumbers applying to the State Committee of Plumbing Examiners for a journeyman license, with at least 4 years of experience or the equivalent.
Official links
How to get licensed, step by step
Check the exam calendar
The Department of Health gives the exam on set dates each year. Find the next date and the application deadline on its plumbing page.
Apply
Send the application, the $75 fee and proof of experience to the State Committee of Plumbing Examiners.
Study the Department's guide
The Department publishes a study guide for each license that shows how the four sections are laid out: drawings and sizing, 50 code questions, gas piping and venting. Work its sample problems.
Retest what you missed
A retest is $50 for each failed portion, so you do not repeat sections you passed.
How to prepare
- The code questions come from the 2018 Arkansas Plumbing Code, the 2018 Arkansas Fuel Gas Code and the Arkansas State Plumbing Law. Use the Arkansas versions, which carry the state amendments.
- The exam is four hours with four sections that are not timed individually. Do the drawing and sizing sections carefully first; they take the longest.
- Practice water system sizing with 2018 APC Appendix E and gas pipe sizing with the Fuel Gas Code longest-length method (Appendix A).
- Journeyman only: a 45-degree offset calculation and identifying components from three code illustrations.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 Arkansas Plumbing Code and the 2018 Arkansas Fuel Gas Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 Arkansas Plumbing Code (2018 IPC with Arkansas amendments)Essential
The code section and sizing sections come from this book, including Appendix E.
2018 Arkansas Fuel Gas Code (2018 IFGC with Arkansas amendments)Essential
Gas piping, venting and combustion air: Chapter 5 and Chapter 3, and the Appendix A sizing tables.
Official reference list (as published by the testing agency)
- 2018 Arkansas Plumbing Code (2018 International Plumbing Code with Arkansas amendments), including Appendix E
- 2018 Arkansas Fuel Gas Code (2018 International Fuel Gas Code with Arkansas amendments)
- Arkansas State Plumbing Law
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Plumbing Law and Administration | 6 | |
| Fixtures and Water Supply | 12 | |
| Drainage, Waste and Vents | 14 | |
| Water System Sizing (Appendix E) | 4 | |
| Fuel Gas Piping and Appliances | 8 | |
| Venting and Combustion Air | 6 |
Exam day details
- Administered by Arkansas Department of Health, State Committee of Plumbing Examiners.
- Fee: $75 application fee; $50 retest fee for each failed portion.
- Our practice exam uses the 50-question code format and a 2-hour timer; the real exam is four hours across four sections.
- The Department of Health gives this exam itself on set calendar dates, not through Prov or PSI. The exam is four hours in total across four sections.
- The code section is 50 random questions from the 2018 Arkansas Plumbing Code, the 2018 Arkansas Fuel Gas Code and the Arkansas State Plumbing Law.
- Application fee: $125 for a master, $75 for a journeyman. A retest costs $50 per failed portion.
- Pass score is not printed in the study guide; see the note on this page.
Note: The Department of Health's study guides do not print the pass score or give the weight of each section, so the pass score (70% assumed) and topic split are unverified. Only the 50 code questions and the sizing calculations fit multiple choice; the drawing sections are not practiced here.
Frequently asked questions
What's on the Arkansas journeyman plumber exam?
Four sections: a drainage riser drawing with water system sizing and a 45-degree offset calculation, 50 random code questions, a gas pipe section (flue venting, combustion air and gas pipe sizing) and identifying components from three code illustrations.
Which code books does it use?
The 2018 Arkansas Plumbing Code (2018 IPC with Arkansas amendments), the 2018 Arkansas Fuel Gas Code and the Arkansas State Plumbing Law.
What does it cost?
A $75 application fee for the journeyman exam, plus $50 for each failed portion you retest.
Free questions with answers
Show all 10 free questions and answers
A plumber is roughing in a water closet next to a wall in a new bathroom. What is the minimum distance allowed from the centerline of the water closet to the side wall?
Answer: 15 inches
APC 405.3.1 requires a water closet, urinal, lavatory or bidet to be at least 15 inches from its center to any side wall, partition, vanity or other obstruction. The 21-inch figure in the same section is the minimum clear space in front of the fixture, not the side distance, and 12 inches applies only to accessible children's water closets.
Reference: 2018 Arkansas Plumbing Code, Section 405.3.1
A flush tank water closet has an anti-siphon fill valve. Where is its backflow preventer located relative to the overflow pipe?
Answer: At least 1 inch above the full opening of the overflow pipe
Section 415.3.1 requires flush tanks to have an antisiphon fill valve conforming to ASSE 1002 or CSA B125.3 and the fill valve backflow preventer must be at least 1 inch above the full opening of the overflow pipe. Below the overflow could allow tank water to be drawn back into the supply.
Reference: 2018 Arkansas Plumbing Code, Section 415.3.1
A 4-inch horizontal building drain runs 40 feet in a straight line at the minimum slope allowed by Table 704.1. How many inches of total fall does the run need?
Answer: 5 inches
Table 704.1 requires 1/8 inch per foot for pipe 3 to 6 inches. Fall = 40 ft x 1/8 in/ft = 5 inches. Ten inches comes from using the 1/4 inch per foot slope for pipe of 2 1/2 inches or less, and 2 1/2 inches from the 1/16 inch per foot slope for 8-inch and larger pipe.
Reference: 2018 Arkansas Plumbing Code, Table 704.1
A 4-inch building drain connects to a closet bend fitting with a 4-inch inlet and a 3-inch outlet that feeds a water closet flange. Why is this not considered a prohibited reduction in the direction of flow?
Answer: A 4-inch by 3-inch closet bend with the 4-inch leg upright and below the flange is specifically excepted
Section 704.2 says drainage piping shall not be reduced in size in the direction of flow, but lists exceptions: a 4 by 3 inch water closet flange, a closet bend with a 4-inch inlet and 3-inch outlet whose 4-inch leg is upright and below the flange, and an offset closet flange. No exception is based on slope, position or venting.
Reference: 2018 Arkansas Plumbing Code, Section 704.2
What is the minimum experience an applicant must have to sit for the Arkansas journeyman plumber examination?
Answer: Four years, or the equivalent
The licensing rules require a minimum of four years of experience, or its equivalent, for the journeyman examination and five years for the master plumber examination. The five-year figure is the master requirement.
Reference: Arkansas Rules Pertaining to Master, Journeyman, and Restricted Plumber Licenses (eff. 9/5/2024), Section II(a)(i), Qualifications
Under the Arkansas Plumbers Law, what is the maximum civil penalty the Committee of Plumbing Examiners may assess for each violation of the chapter or Board rules?
Answer: $1,000, with each day of a continuing violation treated as a separate violation
Ark. Code 17-38-102(d) allows a civil penalty not exceeding $1,000 for each violation, and each day of a continuing violation may be deemed a separate violation. The $100 to $500 range is the criminal misdemeanor fine for working without a required license.
Reference: Arkansas Plumbers Law (Ark. Code Title 17, Ch. 38), Ark. Code 17-38-102(d)
What is the minimum diameter allowed for a water service pipe that supplies a structure?
Answer: 3/4 inch
Section 603.1 requires the water service pipe to be sized to deliver the required quantities and pressures and to be not less than 3/4 inch in diameter. Half-inch pipe is the minimum for many individual fixture supplies, but not for the service.
Reference: 2018 Arkansas Plumbing Code, Section 603.1
A gas line to a gas grill on a patio is buried in a location not subject to physical damage and approved by the administrative authority. What is the minimum cover?
Answer: 8 inches below finished grade
Section 404.12.1 of the Arkansas Fuel Gas Code allows individual lines to outside lights, grills and other appliances to be installed at least 8 inches below finished grade where approved and where not susceptible to physical damage. Other underground gas piping needs 12 inches (404.12).
Reference: 2018 Arkansas Fuel Gas Code, Section 404.12.1
An underground gas line runs near a water service. What is the minimum clearance from the water or sewer pipe, and may they share a ditch?
Answer: At least 8 inches; sharing a ditch is prohibited unless approved by the state administrative authority
Section 404.12 says underground gas piping must not be closer than 8 inches to a water or sewer pipe and that laying gas piping in the same ditch with water, sewer or drainage pipe is prohibited except when approved by the state administrative authority.
Reference: 2018 Arkansas Fuel Gas Code, Section 404.12
A furnace (80,000 Btu/h) and a water heater (40,000 Btu/h) share a room. Using the standard method for indoor combustion air, what is the minimum volume the space must have to be treated as providing its own combustion air?
Answer: 6,000 cubic feet
Section 304.5.1 requires 50 cubic feet per 1,000 Btu/h of the appliance input rating. Total input = 80,000 + 40,000 = 120,000 Btu/h, so volume = 120 x 50 = 6,000 cubic feet. Using 40 per 1,000 gives 4,800, and 20 per 1,000 gives 2,400.
Reference: 2018 Arkansas Fuel Gas Code, Section 304.5.1
Sources
Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.