Alabama licensing exam

Alabama Master Plumber Exam: Practice Test & Licensing Guide

The Prov exam for the Alabama master plumber license: 100 open-book questions on the 2021 IPC, sizing and design, installation, trade math, water heaters, drainage and fixtures. 70% to pass.

Questions
100
Time limit
4.166666666666667 hours
Passing score
70%
Books
Open book

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Roof Drain Systems

A 12,000-square-foot roof is designed as a controlled-flow roof drain system. What is the minimum number of roof drains required?

Requirements at a glance

AgencyAlabama Plumbers and Gas Fitters Examining Board (PGFB); exam by Prov
Exam100 questions, 250 minutes, 70% to pass, open book
Books allowed2021 IPC, Mathematics for Plumbers and Pipefitters (8th), Modern Plumbing (8th), Admin. Code ch. 720 and Ala. Code Title 34 Ch. 37
Fee$160 to the Board; master applicants also pass a separate Business Law exam (since 1/1/2026)

Plumbers applying for an Alabama master plumber license from the Plumbers and Gas Fitters Examining Board.

How to get licensed, step by step

  1. Meet the eligibility requirement

    The Board's application asks for 1 year of current work as a journeyman plumber.

    Alabama Plumbers and Gas Fitters Examining Board (opens in a new tab)

  2. Apply to the board

    Send the Board your application and fee. After you pass, send the Board your pass certificate within 90 days.

    Alabama Plumbers and Gas Fitters Examining Board (opens in a new tab)

  3. Schedule with Prov

    Exam fees are handled through the Board, not paid to Prov. Prov grades the exam right away and sends your result to the board. If you fail, wait 30 days before retesting.

    Schedule with Prov (opens in a new tab)

  4. Bring your references

    All of these exams are open book. Bring the exact books the bulletin lists; permanent tabs and pen highlighting are allowed, sticky notes and loose notes are not.

    Prov bookstore (reference books) (opens in a new tab)

How to prepare

  • Sizing and design (16), system installation (16) and general knowledge (15) are almost half the exam.
  • Water heaters (9) and drawings and plan reading (9) are heavier than on the journeyman exam; practice reading isometrics.
  • Add the formulas you use to your reference books; handwritten formulas are allowed.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

    Official reference list (as published by the testing agency)
    • International Plumbing Code (IPC), 2021 edition (allowed in the exam room)
    • Mathematics for Plumbers and Pipefitters, 8th Edition (allowed in the exam room)
    • Modern Plumbing, 8th Edition, Goodheart-Willcox (allowed in the exam room)
    • Alabama Administrative Code Chapter 720 (2018) and Code of Alabama 2022, Title 34, Chapter 37, Plumbers and Gas Fitters (allowed in the exam room)

    What's on the exam

    Official content outline from Prov, Inc. (number of questions per topic):

    TopicQuestions
    General Knowledge15
    Drawings and Plan Reading9
    Sizing and Design16
    System Installation16
    Trade Math7
    Tools5
    Water Heaters9
    Roof Drain Systems6
    Fixtures and Fittings6
    Drain Waste and Vents6
    Safety5

    Exam day details

    • Administered by Prov, Inc. for the Alabama Plumbers and Gas Fitters Examining Board.
    • Fee: $160 to the Plumbers and Gas Fitters Examining Board with your application. Board license fees are separate.
    • 100 questions in 250 minutes; 70% to pass.
    • Eligibility per the Board's application: 1 year of current work as a journeyman plumber.
    • Since January 1, 2026 master plumber applicants must also pass the Alabama Business Law exam ($100); it is a separate exam and is not part of this practice bank.
    • Prov (provexam.com, (801) 733-4455) gives the exam for the Alabama Plumbers and Gas Fitters Examining Board (PGFB). Exam fees are handled through the Board, not paid to Prov.
    • A new Board approval is required before each attempt, and you wait 30 days to retest.
    • Open book. Hand-written formulas are allowed in the reference books on this exam (the bulletin notes this for the listed books); sticky notes are not allowed.

    Frequently asked questions

    What's on the Alabama master plumber exam?

    100 questions: sizing and design 16, system installation 16, general knowledge 15, drawings and plan reading 9, water heaters 9, trade math 7, tools 5, roof drain systems 6, fixtures and fittings 6, drain waste and vents 6 and safety 5.

    Is there a gas section?

    The master plumber blueprint has no separate gas or Alabama law section; gas fitters take their own exams.

    Do master plumbers take a business exam too?

    Our research notes say that since January 1, 2026 master applicants must also pass the Board's Business Law exam. Confirm on the Board's application.

    Free questions with answers

    Show all 10 free questions and answers
    1. A 12,000-square-foot roof is designed as a controlled-flow roof drain system. What is the minimum number of roof drains required?

      Answer: Four

      Section 1110.4 requires at least two roof drains on roof areas of 10,000 square feet or less and at least four roof drains on roofs over 10,000 square feet. At 12,000 square feet the roof exceeds the threshold, so four drains are required.

      Reference: 2021 International Plumbing Code, 1110.4

    2. A 4-inch drainage stack ends in a horizontal building drain. How far downstream from the stack must the nearest horizontal branch connect to the base of that stack?

      Answer: At least 40 inches

      Section 704.3 requires horizontal branches to connect to the base of a stack not less than 10 times the stack diameter downstream. 10 x 4 inches = 40 inches (3 ft 4 in). The same 10-diameter rule applies at horizontal stack offsets.

      Reference: 2021 International Plumbing Code, 704.3

    3. What is the maximum temperature setting, and the maximum pressure setting, allowed for the temperature and pressure relief valve on a storage water heater?

      Answer: 210°F and the tank rated pressure or 150 psi, whichever is less

      Section 504.5 requires a labeled valve with a temperature setting of not more than 210°F and a pressure setting that does not exceed the tank manufacturer's rated working pressure or 150 psi, whichever is less. Its relieving capacity must also equal or exceed the heat input to the heater.

      Reference: 2021 International Plumbing Code, 504.5

    4. A 60-foot horizontal run of 3-inch sanitary drain is installed at the code minimum slope. How much total fall does the run have?

      Answer: 7.5 inches

      Table 704.1 requires 1/8 inch per foot for 3- to 6-inch drains. Fall = 60 ft x 1/8 in = 7.5 inches. Using 1/4 inch per foot (the 2-1/2 inch and smaller rate) gives 15 inches, and using 1/16 gives 3.75.

      Reference: 2021 International Plumbing Code, Table 704.1

    5. What is the minimum distance from the centerline of a water closet to a side wall or partition?

      Answer: 15 inches

      Section 405.3.1 requires a water closet, urinal, lavatory or bidet to be at least 15 inches from its center to any side wall, partition, vanity or obstruction. The 21-inch figure is the clear space required in front of the fixture, and 30 inches is the center-to-center spacing between adjacent unpartitioned closets or urinals.

      Reference: 2021 International Plumbing Code, 405.3.1

    6. What minimum flow pressure must the water distribution system provide at the supply outlet of a blow-out type flushometer valve water closet?

      Answer: 45 psi

      Table 604.3 lists the blow-out flushometer valve closet at 25 gpm and 45 psi. A siphonic flushometer valve closet needs 35 psi, and a tank-type closet only 20 psi. This is why flushometer valve buildings need larger supply sizing.

      Reference: 2021 International Plumbing Code, 604.3, Table 604.3

    7. For a solvent-cemented joint in PVC drain pipe, which is a correct description of the products used under Section 705.10.2?

      Answer: A purple primer, then solvent cement that is not purple

      Section 705.10.2 requires joint surfaces to be clean and free of moisture, a purple primer conforming to ASTM F656 to be applied, then solvent cement (not purple in color) to all joint surfaces, and the joint made while the cement is wet. A narrow exception waives the primer in specific conditions.

      Reference: 2021 International Plumbing Code, 705.10.2

    8. Under Board Rule 720-X-1-.02, which code sets the minimum standards for commercial plumbing installation, service and repair by certified plumbing contractors where no local code is adopted?

      Answer: 2021 International Plumbing Code

      Rule 720-X-1-.02(1)(b) requires certified plumbing contractors to comply with the minimum standards of the 2021 International Plumbing Code for commercial plumbing installations, service and repairs. The 2021 International Residential Code applies to residential plumbing under paragraph (a).

      Reference: Alabama Admin. Code ch. 720-X (Plumbers and Gas Fitters Examining Board), 720-X-1-.02(1)(b)

    9. A riser diagram shows 4 floors, each with one bathroom group (1.6 gpf water closet) and one kitchen sink with a dishwasher. What is the total drainage fixture unit load on the stack?

      Answer: 28 dfu

      Per Table 709.1, a bathroom group with a 1.6 gpf closet is 5 dfu and a kitchen sink with a dishwasher is 2 dfu (the table lists the sink with disposer, dishwasher or both as one 2-dfu item), so each floor adds 5 + 2 = 7 dfu. Four floors: 4 x 7 = 28 dfu. Counting only three floors gives 21, and leaving out the kitchen sinks with a 6-dfu group gives 24.

      Reference: 2021 International Plumbing Code, 709.1, Table 709.1

    10. What does the IPC require regarding access to a backwater valve?

      Answer: Access must be provided to its working parts

      Section 714.3 requires backwater valves to be installed so that access is provided to the working parts. A buried valve that cannot be serviced would not meet this requirement.

      Reference: 2021 International Plumbing Code, 714.3

    Sources

    Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.