South Carolina licensing exam

South Carolina Non-Structural Renovation Contractor Exam: Practice Test & Licensing Guide

PSI's open-book technical exam for South Carolina's non-structural renovation classification: 60 questions on windows and doors, rough and finish carpentry, drywall, metal stud framing, siding and OSHA safety.

Questions
60
Time limit
2.5 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Drywall

A ceiling framed 24 inches on center is hung with 1/2-inch regular gypsum board that will receive a spray-applied water-based texture. What does the residential table footnote require?

Requirements at a glance

AgencySouth Carolina Department of Labor, Licensing and Regulation (LLR), Contractor's Licensing Board; exams by PSI
ExperienceThe primary qualifying party needs 2 of the last 5 years of full-time experience in the classification, in a management role (S.C. Code 40-11-230)
ExamsNon-Structural Renovation: 60 questions, 2.5 hours, 70%, plus Business Management and Law (Commercial); 70% on each
Books allowedIBC 2021 or 2024 (SC), Carpentry and Building Construction, the Gypsum Construction Handbook and the Finish Carpenter's Manual
FeesPSI exam fees ($64 to $78 per exam), plus the Board's application and license fees and a financial statement or bond

Applicants for a South Carolina Contractor's Licensing Board specialty license in the Non-Structural Renovation classification (interior and exterior remodeling and finishes that do not alter load-bearing parts of a structure).

How to get licensed, step by step

  1. Check the work needs a license

    South Carolina requires a Contractor's Licensing Board license for commercial work above $10,000 in job cost (S.C. Code 40-11-30). Commercial licenses also cover residential work.

    SC Contractor's Licensing Board (LLR) (opens in a new tab)S.C. Code Title 40 Chapter 11 (contractors) (opens in a new tab)

  2. Apply to the Board

    Apply to the Contractor's Licensing Board for an eligibility letter before you register with PSI.

    SC Contractor's Licensing Board (LLR) (opens in a new tab)

  3. Schedule Business and Law and the non-structural renovation exam with PSI

    Register for each exam separately. You may take each trade exam twice in 12 months, then once every six months. Commercial Business and Law has no such limit.

    Schedule with PSI (commercial contractors) (opens in a new tab)

  4. Apply for the license

    After you pass, the business entity applies with its primary qualifying party, a financial statement or bond, and the license fee. The group (1 to 5) sets the dollar limit of work you may bid.

    SC Contractor's Licensing Board (LLR) (opens in a new tab)S.C. Code Title 40 Chapter 11 (contractors) (opens in a new tab)

How to prepare

  • Code editions are changing. From November 1, 2026 PSI accepts the 2021 or the 2024 South Carolina codes (ICC codes with state modifications) and the 2023 or the 2020 NEC. After July 1, 2027 only the 2024 codes and the 2023 NEC. Bring one edition you know well and expect questions that read the same in both.
  • Tab your books before exam day: highlighting, underlining and permanent tabs are allowed, but sticky notes and writing during the exam are not.
  • Associated trades (9), windows and doors (8), rough carpentry (8), drywall (8) and metal stud framing (8) are the core of the exam.
  • The license does not cover alterations to load-bearing portions of a structure; questions stay with interior and exterior finish work.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the SC IBC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Building Code (IBC), 2021 or 2024 edition with South Carolina modifications
  • Carpentry and Building Construction, 2016 (Student Edition)
  • Gypsum Construction Handbook, 7th Edition; Finish Carpenter's Manual
  • The Complete Illustrated Guide to Furniture and Cabinet Construction; 29 CFR Part 1926 (all on PSI's list)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Plan Reading and Estimating4
Windows and Doors8
Associated Trades (insulation, moisture control, flooring, general finishing)9
Rough Carpentry8
Finish Carpentry6
Siding4
Drywall8
Metal Stud Framing8
OSHA Safety5

Exam day details

  • Administered by PSI Services for the South Carolina Department of Labor, Licensing and Regulation (Contractor's Licensing Board).
  • Fee: $64 to PSI. Board application and license fees are separate.
  • 60 scored questions plus 1 to 10 unscored experimental items (they count against your time) in 150 minutes; 42 correct (70%).
  • Code editions: from November 1, 2026 PSI accepts the 2021 or 2024 South Carolina codes (NEC 2023 or 2020); after July 1, 2027 only the 2024 codes and the 2023 NEC. Our questions are written to be correct under both.
  • Open book: bring the references on PSI's list. You may highlight, underline and add permanent tabs (tabs that would tear the page if removed); sticky notes and removable tabs are not allowed.
  • Apply to the Contractor's Licensing Board first. After approval you get an eligibility letter and register with PSI (855-340-3701) for each exam; the registration confirmation is valid 1 year or until a classification has been failed twice.
  • You may take each trade exam twice in 12 months, then once every six months.
  • Every Contractor's Licensing Board license needs the Business Management and Law exam and the technical exam for the classification, 70% on each (S.C. Code 40-11-230).

Frequently asked questions

What's on the South Carolina non-structural renovation exam?

60 scored questions: associated trades 9, windows and doors 8, rough carpentry 8, drywall 8, metal stud framing 8, finish carpentry 6, OSHA safety 5, siding 4 and plan reading and estimating 4.

Does the license allow structural work?

No. The classification does not include alterations to load-bearing portions of a structure.

Which exams do I take for this license?

Business Management and Law (Commercial) and this technical exam, 70% on each, both through PSI.

Free questions with answers

Show all 10 free questions and answers
  1. A ceiling framed 24 inches on center is hung with 1/2-inch regular gypsum board that will receive a spray-applied water-based texture. What does the residential table footnote require?

    Answer: Increase to 5/8-inch board, or use 1/2-inch sag-resistant gypsum ceiling board

    The Table R702.3.5 note on ceilings says that where a water-based texture is applied, the minimum thickness rises from 1/2 inch to 5/8 inch for 24-inch framing, or 1/2-inch sag-resistant ceiling board is used. The board must also be applied perpendicular to the framing. Three-eighths-inch single-ply board is prohibited under water-based texture altogether.

    Reference: IRC 2021 and 2024 (South Carolina Residential Code), R702.3.5, Table R702.3.5 note d

  2. A remodel adds a partition of lightweight steel drywall studs that carries no floor or roof load. Which AISI standard governs nonload-bearing cold-formed steel framing under the residential code?

    Answer: AISI S220

    Section R702.3.3 says nonload-bearing cold-formed steel framing supporting gypsum board shall comply with AISI S220, while load-bearing cold-formed steel framing shall comply with AISI S240. Studs made only for drywall must not be substituted for load-bearing members.

    Reference: IRC 2021 and 2024 (South Carolina Residential Code), R702.3.3

  3. Vinyl siding is installed vertically on a small addition. Where the manufacturer gives no other spacing, what is the maximum nail spacing, and where in the nail slot is the nail driven?

    Answer: 12 inches on center, in the middle third of the slot

    Fasteners go in the middle third of the slots in the nail hem so the siding can expand and contract, and the spacing is not more than 16 inches for horizontal siding and 12 inches for vertical siding (2021 IBC 1404.14.1.3; 2024 IBC 1404.15.1.3). Nails driven tight would lock the siding and make it buckle.

    Reference: IBC 2021 and 2024 (South Carolina Building Code), 2021 IBC 1404.14.1.3 (2024 IBC 1404.15.1.3)

  4. What is the minimum clear opening width the IBC requires for a means-of-egress door opening, measured with the door open 90 degrees?

    Answer: 32 inches

    Section 1010.1.1 requires a minimum clear opening width of 32 inches, measured between the face of the open door and the stop with the door open 90 degrees. Because the door thickness and stop eat into the opening, a nominal 2'8" leaf does not give 32 inches clear; remodelers normally use a 2'10" or 3'0" leaf. A 36 inch door is a common choice, but 36 inches of clear width is not the code minimum.

    Reference: IBC 2021 and 2024 (South Carolina Building Code), 1010.1.1

  5. Per the fastening schedule, how is the second top plate nailed to the first top plate along the length of the wall when 16d common nails are used?

    Answer: Face-nailed with 16d common nails at 16 inches on center

    Table 2304.10.2 (fastening schedule), item 12, calls for 16d common nails at 16 inches on center, face nail, top plate to top plate. When 10d box nails or 3 inch by 0.131 inch nails are used instead, the spacing tightens to 12 inches on center. The schedule is the same in the 2021 and 2024 IBC.

    Reference: IBC 2021 and 2024 (South Carolina Building Code), Table 2304.10.2, item 12

  6. A non-self-supporting 16-foot ladder (working length 16 feet) is leaned against a wall. At about what horizontal distance from the wall should its foot be placed?

    Answer: 4 feet

    29 CFR 1926.1053(b)(5)(i) says non-self-supporting ladders are used at an angle where the horizontal distance from the top support to the foot is approximately one-quarter of the working length: 16 / 4 = 4 feet. Two feet (1/8) is the rule for job-made wood ladders with spliced rails, and 6 or 8 feet would lay the ladder too flat and invite slipping.

    Reference: 29 CFR 1926 (OSHA Safety and Health Standards for Construction), 1926.1053(b)(5)(i)

  7. Under the vapor retarder classification table, which material is a Class I vapor retarder (perm rating of 0.1 or less)?

    Answer: Sheet polyethylene

    Table 1404.3(1) lists sheet polyethylene and nonperforated aluminum foil as Class I (0.1 perm or less). Kraft-faced fiberglass batts and vapor retarder paint are Class II (over 0.1 up to 1.0 perm), and latex or enamel paint is Class III (over 1.0 up to 10 perm). The table is the same in the 2021 and 2024 IBC.

    Reference: IBC 2021 and 2024 (South Carolina Building Code), 1404.3, Table 1404.3(1)

  8. Where the building code calls for a vapor retarder in a frame exterior wall (with listed exceptions such as below-grade walls), on which side of the wall does it go?

    Answer: The interior side of the wall

    Section 1404.3 says a vapor retarder shall be provided on the interior side of frame walls in accordance with the climate-zone tables, with exceptions such as basement walls, below-grade portions of walls, and construction where moisture accumulation will not damage the materials. The interior side is the warm-in-winter side where humid indoor air would otherwise condense.

    Reference: IBC 2021 and 2024 (South Carolina Building Code), 1404.3

  9. What is the permitted height range for a stair handrail under the IBC?

    Answer: 34 to 38 inches, measured above the stair nosings

    Section 1014.2 requires handrail height to be uniform and not less than 34 inches nor more than 38 inches, measured above stair tread nosings (a line connecting the nosings in the 2024 text). The 30 to 34 inch range is for alternating tread devices and ships ladders, and 42 inches is the minimum guard height.

    Reference: IBC 2021 and 2024 (South Carolina Building Code), 1014.2

  10. A room is 14 feet 6 inches by 12 feet. Plank flooring comes in cartons of 20 square feet and the estimator adds 10 percent for waste. How many cartons should be ordered?

    Answer: 10 cartons

    Area = 14.5 x 12 = 174 square feet. With 10 percent waste: 174 x 1.10 = 191.4 square feet. Cartons = 191.4 / 20 = 9.57, which rounds up to 10. Nine cartons (174 / 20 = 8.7) ignores the waste and does not cover the room.

    Reference: General construction estimating practice, Flooring quantity takeoff

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.