Rhode Island Commercial Roofing Contractor Exam: Practice Test & Licensing Guide

The CRB's PSI exam for a Rhode Island commercial roofing license: 50 open-book questions in 2 hours on low slope, steep slope and metal roofing, moisture control, reroofing and safety. 70% to pass.

Questions
50
Time limit
2 hours
Passing score
70%
Books
Open book

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Roofing Knowledge

A roof rises 6 inches vertically for every 12 inches of horizontal run. How is that slope expressed?

Requirements at a glance

AgencyRhode Island Contractors' Registration and Licensing Board (CRB); exam by PSI
Exam50 questions, 2 hours, open book, 70% to pass (35 correct)
ExperienceNone to sit the exam; the CRB has its own licensing requirements
Books allowed29 CFR 1926; the NRCA Roofing Manuals (Steep Slope 2021 or 2025, Membrane 2023, Metal Panel and SPF 2024, Architectural Metal Flashing/Reroofing 2022); Roofing Construction & Estimating (Atcheson); RI Building Code SBC-1 2019; RI Plumbing Code 2019
Fees$180 to PSI per exam; CRB application and license fees are separate

Contractors who do commercial or industrial roofing, including related sheet metal work, on nonresidential buildings. Roofers who only apply shingles are outside the licensing requirement.

How to get licensed, step by step

  1. Schedule with PSI and sit the exam

    No application is needed first: register at test-takers.psiexams.com/ricon or call 855-746-8173, pay the $180 fee (valid for one year, not refundable or transferable), and bring two forms of signed ID, one with a photo. You see your result when you finish.

    Schedule with PSI (Rhode Island CRB) (opens in a new tab)PSI: Rhode Island CRB Candidate Information Bulletin (opens in a new tab)

  2. Apply to the CRB

    After you pass, send your application to the CRB, which has its own requirements and fees. If you fail, you retake the exam (and pay again) before you can apply.

    Rhode Island Contractors' Registration and Licensing Board (opens in a new tab)

How to prepare

  • Low slope (12) and steep slope (10) roofing are 22 of 50 questions.
  • The NRCA Steep Slope manual 2021 edition isn't allowed from 3/15/2026; bring the 2025 edition.
  • The exam is open book with permanent tabs and highlighting only; no writing in your books, no sticky notes. 70% to pass, and 1 to 5 unscored experimental questions may be added.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

    Official reference list (as published by the testing agency)
    • 29 CFR Part 1926 (OSHA construction), latest amendments, or 29 CFR 1926 Selections by PSI
    • NRCA Roofing Manual: Steep Slope Roof Systems, 2021 or 2025 (the 2021 edition isn't allowed from 3/15/2026)
    • NRCA Roofing Manual: Membrane Roofing Systems, 2023
    • NRCA Roofing Manual: Metal Panel and SPF Roof Systems, 2024
    • NRCA Roofing Manual: Architectural Metal Flashing, Condensation and Air Leakage Control, and Reroofing, 2022
    • Roofing Construction & Estimating, Daniel Atcheson, 1995 (Craftsman Book Company)
    • State of Rhode Island Building Code SBC-1, 2019 (ICC and NASCLA)
    • State of Rhode Island Plumbing Code, 2019 (ICC)

    What's on the exam

    Official content outline from PSI Services (number of questions per topic):

    TopicQuestions
    General Roofing Knowledge4
    Low Slope Roofing12
    Steep Slope Roofing10
    Architectural Metal Roofing Systems and Sheet Metal Flashing7
    Moisture and Energy Control6
    Repairs and Reroofing6
    Safety5

    Exam day details

    • Administered by PSI Services for the Rhode Island Contractors' Registration and Licensing Board (CRB).
    • Fee: $180 to PSI per exam. Not refundable or transferable, and valid for one year from payment. CRB application and license fees are separate.
    • 50 questions in 2 hours; 35 correct (70%) to pass.
    • Open book: bring your own copies of the listed references. You may highlight, underline and index them with permanent tabs, but not write in them; sticky notes and loose papers are removed.
    • A small number (1 to 5) of unscored experimental questions may be added; their time doesn't count against your time.
    • Bring two forms of ID with your signature, one with a photo, in the name on your registration, and arrive 30 minutes early.
    • There are no prerequisites to sit the exam. You pass it first and then apply to the CRB. You see your result when you finish, and you pay again to retake.
    • The PSI bulletin says code questions use only the edition listed; other references may use later editions.

    Frequently asked questions

    What's on the Rhode Island commercial roofing exam?

    50 questions: low slope roofing 12, steep slope roofing 10, architectural metal roofing systems and sheet metal flashing 7, moisture and energy control 6, repairs and reroofing 6, safety 5 and general roofing knowledge 4.

    Is it open book?

    Yes, with the listed references only. You may highlight and add permanent tabs, but not write in them.

    Do I need experience to sit the exam?

    No. PSI lists no prerequisites. You pass the exam and then apply to the CRB, which has its own requirements.

    Free questions with answers

    Show all 10 free questions and answers
    1. A roof rises 6 inches vertically for every 12 inches of horizontal run. How is that slope expressed?

      Answer: 6:12, which is a 50 percent slope

      Slope is the tangent of the roof angle, written as rise over a 12-inch run, so 6 / 12 = 0.50 or 50 percent. The IBC uses the same conversion (2:12 = 17 percent, 4:12 = 33 percent). 1:6 is the same as 2:12, and 12:6 inverts the ratio.

      Reference: UFC 3-110-03 Roofing (1 May 2012, Change 5), Appendix C Glossary, definitions of Slope and Roof Slope

    2. A coal-tar pitch built-up roof is being designed for a new commercial building. What is the minimum design slope allowed by the IBC?

      Answer: 1/8 unit vertical in 12 units horizontal (1 percent)

      Section 1507.10.1 sets 1/4:12 for built-up roofs but makes an exception for coal-tar built-up roofs, which need only 1/8:12. The 1/4:12 answer is the tempting one because it applies to asphalt BUR.

      Reference: 2021 International Building Code (RI State Building Code, Chapter 15 adopted without change), Section 1507.10.1

    3. Which coating is listed in IBC Table 1507.13.3 as a protective coating for sprayed polyurethane foam roofing?

      Answer: Silicone coating complying with ASTM D6694

      Table 1507.13.3 lists acrylic (ASTM D6083), silicone (ASTM D6694) and moisture-cured polyurethane (ASTM D6947) coatings. The three asphalt-based coatings appear in the general roof coating table, Table 1509.2, not in the foam table.

      Reference: 2021 International Building Code (RI State Building Code, Chapter 15 adopted without change), Table 1507.13.3

    4. What is the minimum roof slope on which the IBC allows asphalt shingles to be used?

      Answer: 2 units vertical in 12 units horizontal (17 percent)

      Section 1507.2.2 allows asphalt shingles only on slopes of 2:12 or greater. Between 2:12 and 4:12 double underlayment is required.

      Reference: 2021 International Building Code (RI State Building Code, Chapter 15 adopted without change), Section 1507.2.2

    5. Asphalt shingles are to be installed on a roof with a 3:12 slope. What underlayment application does the IBC require?

      Answer: Double underlayment application

      For slopes from 2:12 up to 4:12, Section 1507.2.2 requires double underlayment application in accordance with Section 1507.1.1. The ice barrier is separate and tied to a history of ice backup at the eaves.

      Reference: 2021 International Building Code (RI State Building Code, Chapter 15 adopted without change), Sections 1507.2.2 and 1507.1.1

    6. What is the minimum slope for lapped, nonsoldered-seam metal roof panels without applied lap sealant?

      Answer: 3 units vertical in 12 units horizontal (25 percent)

      Section 1507.4.2 sets 3:12 for lapped nonsoldered metal panels without sealant, 1/2:12 when lap sealant is applied, and 1/4:12 for standing-seam systems.

      Reference: 2021 International Building Code (RI State Building Code, Chapter 15 adopted without change), Section 1507.4.2

    7. Under the IBC, how low may the roof slope be for a standing-seam metal roof panel system?

      Answer: 1/4 unit vertical in 12 units horizontal (2 percent)

      Section 1507.4.2 allows standing-seam metal roof panel systems on slopes as low as 1/4:12. Lapped panels need 1/2:12 with sealant and 3:12 without.

      Reference: 2021 International Building Code (RI State Building Code, Chapter 15 adopted without change), Section 1507.4.2

    8. What least dimension of ventilation openings in an attic is allowed without added screening under the IBC?

      Answer: Not less than 1/16 inch and not more than 1/4 inch

      Section 1202.2.2 allows ventilation openings with a least dimension from 1/16 inch to 1/4 inch. Larger openings need corrosion-resistant wire cloth, hardware cloth or similar material to keep out birds and rodents.

      Reference: 2021 International Building Code (RI State Building Code, Chapter 12 adopted without change), Section 1202.2.2

    9. Under the IBC, a roof recover is not permitted over which existing roof covering?

      Answer: Slate, clay, cement or asbestos-cement tile

      Section 1512.2.1.1 prohibits a recover over slate, clay, cement or asbestos-cement tile. A recover is also prohibited where the roof already has two or more applications of any type of covering.

      Reference: 2021 International Building Code (RI State Building Code, Chapter 15 adopted without change), Section 1512.2.1.1

    10. Under OSHA's construction fall protection standard, at what unprotected edge height must employees on a walking/working surface be protected from falling?

      Answer: 6 feet or more above a lower level

      29 CFR 1926.501(b)(1) requires protection for unprotected sides and edges 6 feet or more above a lower level. Roofing work on low-slope and steep roofs uses the same 6-foot trigger.

      Reference: 29 CFR Part 1926, Subpart M, 29 CFR 1926.501(b)(1)

    Sources

    Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.