Requirements at a glance
| Agency | Ohio Construction Industry Licensing Board (OCILB); exams by PSI |
|---|---|
| Experience | At least 5 years as a tradesperson in the trade immediately before you apply (registered engineers can qualify with 3 years of construction business experience) |
| Exams | 100 questions, 4 hours, 70%, plus the Contractor's Business and Law exam |
| Books allowed | 2024 Ohio Plumbing Code, 2024 IFGC, Mathematics for Plumbers and Pipefitters and Modern Plumbing |
| Fees | $69 per PSI exam, plus OCILB application and license fees and contractor's liability insurance |
Qualifying individuals for an Ohio commercial plumbing contractor license from the OCILB.
Official links
How to get licensed, step by step
Confirm you qualify
You must be 18, a U.S. citizen or legal resident, and have 5 years in the trade. The OCILB also checks your conduct record.
Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)Ohio Revised Code Chapter 4740 (OCILB) (opens in a new tab)
Apply to the OCILB
Send the exam application and fee to the OCILB. When it approves you, get a state (BCI) and federal (FBI) background check before you sit. Approval is good for one year.
Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)
Schedule the Business and Law exam and the plumbing exam with PSI
Book both exams with PSI ($69 each). If you fail, wait 60 days; you can test up to 5 times in a year. Pass the business and law exam once and it covers any other trade licenses you add for three years.
Schedule with PSI (Ohio contractors) (opens in a new tab)PSI: Ohio contractor trade exam bulletin and outlines (opens in a new tab)
Get insured and licensed
After you pass both exams, send the OCILB your results, the license fee and proof of contractor's liability insurance. Licenses renew every year with 10 hours of continuing education.
Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline. Ohio's code books are the 2024 Ohio Plumbing Code and Ohio Mechanical Code (the 2021 IPC and IMC with Ohio amendments) and the 2023 NEC.
- Tab your books before exam day. You can highlight, underline and index them, but you can't write in them or add loose papers.
- Ohio's licenses are for commercial work. Residential work is handled by local jurisdictions, so questions stay on commercial buildings.
- Drainage, waste and vents (24) is the biggest section. Tab Chapters 7 and 9 and the drain and vent sizing tables.
- Isometric analysis is 20 of the 100 questions. Practice adding fixture units from a riser diagram and sizing the drain and vent from the Chapter 7 and 9 tables.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Ohio Plumbing Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2024 Ohio Plumbing Code (2021 IPC with Ohio amendments)Essential
Allowed in the exam room. Most of the plumbing exam. Code questions are based only on this edition.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
2024 International Fuel Gas Code (IFGC)
Allowed in the plumbing exam room (PSI lists the 2024 edition for plumbing). Gas piping and water heater venting.
Mathematics for Plumbers and Pipefitters, 8th Edition (Cengage)
Allowed in the plumbing exam room. Offsets, grade, volume and pipe-sizing math.
Modern Plumbing, 9th Edition (Goodheart-Willcox)
Allowed in the plumbing exam room. Fixtures, installation methods and trade practice.
Official reference list (as published by the testing agency)
- Ohio Plumbing Code, 2024, based on the 2021 International Plumbing Code (allowed in the exam room)
- International Fuel Gas Code (IFGC), 2024 (allowed in the exam room)
- Mathematics for Plumbers and Pipefitters, 8th Edition, 2013 (allowed in the exam room)
- Modern Plumbing, 9th Edition, 2022, Goodheart-Willcox (allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 8 | |
| General Regulations | 20 | |
| Plumbing Fixtures | 6 | |
| Water Supply Systems | 10 | |
| Drainage, Waste, and Sanitary Vents | 24 | |
| Indirect Wastes | 3 | |
| Roof Drain Piping | 4 | |
| Specialty Plumbing | 5 | |
| Isometric Analysis | 20 |
Exam day details
- Administered by PSI Services for the Ohio Construction Industry Licensing Board (OCILB).
- Fee: $69 to PSI per exam. OCILB application and license fees are separate.
- 100 scored questions plus 1 unscored pretest item in 4 hours; 70 correct (70%) to pass.
- The Ohio Plumbing Code is the 2021 IPC with Ohio amendments; our questions use the Ohio text.
- Open book: bring your own copies of the allowed references. You may highlight, underline and index them beforehand, but not write in them.
- PSI may add unscored pretest questions, which count against your time.
- If you fail an exam, wait 60 days to retest. You can test up to 5 times in a year.
- The OCILB must approve your application first and you need a state and federal background check before you sit. Approval is good for one year.
- Every commercial trade license also needs the Contractor's Business and Law exam, which you pass once every three years however many trade licenses you add.
Frequently asked questions
What's on the Ohio plumbing contractor exam?
100 scored questions: drainage, waste and sanitary vents 24, general regulations 20, isometric analysis 20, water supply systems 10, general knowledge 8, plumbing fixtures 6, specialty plumbing 5, roof drain piping 4 and indirect wastes 3.
Which plumbing code is on the Ohio exam?
The 2024 Ohio Plumbing Code, which adopts the 2021 International Plumbing Code with Ohio amendments.
What is isometric analysis on the Ohio plumbing exam?
Questions that give you a piping layout and ask for fixture units, pipe sizes, slopes or code violations. It is 20 of the 100 scored questions.
Free questions with answers
Show all 10 free questions and answers
A drainage and vent system is being water tested at rough-in before the fixtures are set. After the system is filled, how long must the test pressure be held?
Answer: At least 15 minutes
Section 312.2.1 requires the water test pressure to be held for not less than 15 minutes, after which the system must be tight at all points. The test is done on the whole system or in sections with at least a 10-foot head of water.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), 312.2.1
A plumber tests a completed water supply system with air, as the pipe manufacturer permits. What is the minimum test pressure and hold time?
Answer: 50 psi for at least 15 minutes
Section 312.5.2 sets the water supply air test at not less than 50 psi held at least 15 minutes. The 5 psi figure belongs to the drainage and vent air test in 312.2.2, which is a different system with a much lower test pressure.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), 312.5.2
What is the minimum interior cross-sectional area and least dimension of a standard shower compartment?
Answer: 900 square inches and 30 inches
Section 421.4 requires 900 square inches of interior cross-section and 30 inches in least dimension. The exception allows a compartment with a 25-inch minimum dimension only if it has at least 1,300 square inches of area, which is the second tempting option.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), 421.4
At what static water pressure in a building must an approved pressure-reducing valve be installed to limit the pressure in the distribution piping?
Answer: Over 80 psi
Section 604.8 requires a pressure-reducing valve with a strainer where static pressure in the building exceeds 80 psi, reducing it to not more than 80 psi. Service lines to sill cocks and outside hydrants are excepted.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), 604.8
Under the Ohio Plumbing Code, a water heater must comply with the Ohio Boiler and Pressure Vessel rules when it exceeds which limitation?
Answer: 200,000 Btu/h input, 210°F water, or 120 gallons capacity
The Ohio exception to Section 501.1 sends water heaters to Chapters 4101:4-1 to 4101:4-10 of the Administrative Code when any of these is exceeded: 200,000 Btu/h heat input, 210°F water temperature, or 120 gallons nominal capacity.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), 501.1, Exception
What is the minimum slope for a 3-inch horizontal drainage pipe?
Answer: 1/8 inch per foot
Table 704.1 requires 1/4 inch per foot for pipe 2-1/2 inches and smaller, 1/8 inch per foot for 3- to 6-inch pipe, and 1/16 inch per foot for 8-inch and larger.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), Table 704.1
A branch vent serving a 4-inch horizontal branch drain has a developed length of 45 feet. What is its minimum size?
Answer: 2-1/2 inches
Section 906.2 requires a branch vent to be at least half the drain size, so 4 ÷ 2 = 2 inches. Because the vent exceeds 40 feet in developed length, it must be increased by one nominal pipe size over its entire length, giving 2-1/2 inches.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), 906.2
An automatic clothes washer drains into a standpipe. What is the permitted height of the standpipe above its trap weir?
Answer: At least 18 inches and not more than 42 inches
Section 802.4.3 requires standpipes to be individually trapped and extend not less than 18 inches and not greater than 42 inches above the trap weir, with access for rodding.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), 802.4.3
A commercial toilet room contains 3 public water closets (1.6 gpf), 2 urinals rated at 1 gallon per flush, 4 lavatories and 1 floor drain. Using Table 709.1, what is the total drainage fixture unit load?
Answer: 22 dfu
Water closets: 3 × 4 = 12. Urinals (1 gpf or less): 2 × 2 = 4. Lavatories: 4 × 1 = 4. Floor drain: 1 × 2 = 2. Total = 12 + 4 + 4 + 2 = 22 dfu. Rating the urinals at 4 dfu each gives 26, and leaving out the floor drain gives 20.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), Table 709.1
A drainage stack extends through eight branch intervals and serves a total of 120 dfu, with no more than 18 dfu discharging into any one branch interval. What is the minimum stack size?
Answer: 4 inches
Table 710.1(2): for a stack of more than three branch intervals, a 3-inch stack is limited to 72 dfu total, which is less than 120, so 3 inches fails. A 4-inch stack allows 500 dfu total and 90 dfu per branch interval, so 4 inches is the minimum.
Reference: 2024 Ohio Plumbing Code (2021 IPC with Ohio amendments), Table 710.1(2)
Sources
- PSI: Ohio Contractor Trade Examinations Candidate Information Bulletin (2/7/2024) (opens in a new tab)
- Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)
- Ohio Revised Code Chapter 4740 (opens in a new tab)
Questions last verified October 25, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.