Ohio licensing exam

Ohio Electrical Contractor Exam: Practice Test & Licensing Guide

The PSI trade exam for Ohio's commercial electrical contractor license: 100 questions on the 2023 NEC covering services, raceways, conductors, motors, transformers and special occupancies. Open book.

Questions
100
Time limit
4 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Electrical Knowledge

A heating element with a resistance of 40 ohms is connected to 120 volts. What current does it draw?

Requirements at a glance

AgencyOhio Construction Industry Licensing Board (OCILB); exams by PSI
ExperienceAt least 5 years as a tradesperson in the trade immediately before you apply (registered engineers can qualify with 3 years of construction business experience)
Exams100 questions, 4 hours, 70%, plus the Contractor's Business and Law exam
Books allowed2023 NEC (or NEC Handbook), Ugly's 2023 and the field reference handbooks
Fees$69 per PSI exam, plus OCILB application and license fees and contractor's liability insurance

Qualifying individuals for an Ohio commercial electrical contractor license from the OCILB.

How to get licensed, step by step

  1. Confirm you qualify

    You must be 18, a U.S. citizen or legal resident, and have 5 years in the trade. The OCILB also checks your conduct record.

    Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)Ohio Revised Code Chapter 4740 (OCILB) (opens in a new tab)

  2. Apply to the OCILB

    Send the exam application and fee to the OCILB. When it approves you, get a state (BCI) and federal (FBI) background check before you sit. Approval is good for one year.

    Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)

  3. Schedule the Business and Law exam and the electrical exam with PSI

    Book both exams with PSI ($69 each). If you fail, wait 60 days; you can test up to 5 times in a year. Pass the business and law exam once and it covers any other trade licenses you add for three years.

    Schedule with PSI (Ohio contractors) (opens in a new tab)PSI: Ohio contractor trade exam bulletin and outlines (opens in a new tab)

  4. Get insured and licensed

    After you pass both exams, send the OCILB your results, the license fee and proof of contractor's liability insurance. Licenses renew every year with 10 hours of continuing education.

    Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's outline. Ohio's code books are the 2024 Ohio Plumbing Code and Ohio Mechanical Code (the 2021 IPC and IMC with Ohio amendments) and the 2023 NEC.
  • Tab your books before exam day. You can highlight, underline and index them, but you can't write in them or add loose papers.
  • Ohio's licenses are for commercial work. Residential work is handled by local jurisdictions, so questions stay on commercial buildings.
  • Services, feeders and branch circuits (16) is the biggest section: tab Articles 210, 215, 220, 225, 230, 240 and 250.
  • Motors and generators (12) and transformers (12) mix code and calculations: Articles 430, 445, 450, plus Ugly's formulas.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC and Ugly's. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC) and/or the NEC Handbook, 2023 (allowed in the exam room)
  • Ugly's Electrical References, 2023 (allowed in the exam room)
  • Electrical Field Reference Handbook (NEC 2008) or IBEW-NECA Field Reference Book (allowed in the exam room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Electrical Knowledge10
Transformers and Equipment12
Service Feeders and Branch Circuits16
Raceways, Boxes, and Panelboards10
Conductors and Cables12
Control Devices8
Motors and Generators12
Utilization Equipment8
Special Occupancies and Equipment12

Exam day details

  • Administered by PSI Services for the Ohio Construction Industry Licensing Board (OCILB).
  • Fee: $69 to PSI per exam. OCILB application and license fees are separate.
  • 100 scored questions plus 10 unscored pretest items in 4 hours; 70 correct (70%) to pass.
  • Code questions are based only on the 2023 NEC. Ugly's and the field reference handbooks help with theory and calculations.
  • Open book: bring your own copies of the allowed references. You may highlight, underline and index them beforehand, but not write in them.
  • PSI may add unscored pretest questions, which count against your time.
  • If you fail an exam, wait 60 days to retest. You can test up to 5 times in a year.
  • The OCILB must approve your application first and you need a state and federal background check before you sit. Approval is good for one year.
  • Every commercial trade license also needs the Contractor's Business and Law exam, which you pass once every three years however many trade licenses you add.

Frequently asked questions

What's on the Ohio electrical contractor exam?

100 scored questions: service, feeders and branch circuits 16, transformers and equipment 12, conductors and cables 12, motors and generators 12, special occupancies and equipment 12, raceways, boxes and panelboards 10, general electrical knowledge 10, control devices 8 and utilization equipment 8.

Which NEC edition is on the Ohio electrical contractor exam?

The 2023 NEC. The NEC or the NEC Handbook is enough on its own; you may bring both.

Can I bring Ugly's to the exam?

Yes. Ugly's Electrical References (2023) is on the allowed list. You can highlight and index it but not write in it.

Free questions with answers

Show all 10 free questions and answers
  1. A heating element with a resistance of 40 ohms is connected to 120 volts. What current does it draw?

    Answer: 3 A

    By Ohm's law I = E ÷ R = 120 ÷ 40 = 3 A. Multiplying (120 × 40 = 4,800) is the common mistake.

    Reference: NFPA 70, National Electrical Code, 2023, Ohm's law (Ugly's, Chapter 1 formulas)

  2. A 208-volt, three-phase load draws 36 A at a power factor of 0.90. What is its true power, using P = 1.732 × E × I × PF?

    Answer: About 11.7 kW

    P = 1.732 × 208 × 36 × 0.90 = 11,673 W, about 11.7 kW. Leaving out the power factor gives 13.0 kVA of apparent power, and leaving out both the 1.732 factor and the power factor gives 208 × 36 = 7.5 kVA.

    Reference: NFPA 70, National Electrical Code, 2023, Three-phase power (Ugly's, Chapter 1 formulas)

  3. What is the full-load secondary current of a 112.5-kVA, three-phase transformer with a 208-volt secondary?

    Answer: About 312 A

    I = kVA × 1,000 ÷ (1.732 × E) = 112,500 ÷ (1.732 × 208) = 312.3 A. Leaving out the 1.732 factor gives 541 A.

    Reference: NFPA 70, National Electrical Code, 2023, Transformer current formula (Ugly's, Chapter 1 formulas)

  4. A 208Y/120-volt service drop crosses a commercial parking lot subject to truck traffic. What is the minimum clearance above the pavement?

    Answer: 18 feet

    Section 230.24(B)(4) requires 18 feet over public streets, alleys, roads and parking areas subject to truck traffic. Twelve feet applies over residential property and driveways and commercial areas not subject to truck traffic, and 10 feet applies over areas accessible to pedestrians only.

    Reference: NFPA 70, National Electrical Code, 2023, 230.24(B)

  5. What is the minimum rating of a service disconnecting means in installations other than one-family dwellings, and what is the minimum for a one-family dwelling?

    Answer: 60 A for other installations, and 100 A for a one-family dwelling

    Section 230.79 sets the minimum rating of the service disconnect: 15 A for installations with a single circuit, 30 A for two circuits, 60 A for other installations (230.79(D)) and 100 A for a one-family dwelling (230.79(C)).

    Reference: NFPA 70, National Electrical Code, 2023, 230.79

  6. Using Chapter 9 Table 1 (40 percent fill), Table 4 (1-inch EMT, 40 percent = 0.346 square inch) and Table 5 (10 AWG THHN = 0.0211 square inch), what is the maximum number of 10 AWG THHN conductors in 1-inch EMT?

    Answer: 16

    More than two conductors may fill 40 percent of the raceway: 0.346 ÷ 0.0211 = 16.4, rounded down to 16 conductors. You cannot round up, because the fill would exceed 40 percent.

    Reference: NFPA 70, National Electrical Code, 2023, Chapter 9 Table 1, Table 4 and Table 5

  7. Using the 75°C column of Table 310.16, what is the ampacity of a 3/0 AWG copper conductor?

    Answer: 200 A

    In Table 310.16 a 3/0 AWG copper conductor has an ampacity of 165 A at 60°C, 200 A at 75°C and 225 A at 90°C. 230 A is the 75°C value for 4/0 AWG.

    Reference: NFPA 70, National Electrical Code, 2023, Table 310.16

  8. What is the maximum height above the floor of the center of the grip of the operating handle of a snap switch or circuit breaker in its highest position?

    Answer: 6 feet 7 inches

    Sections 404.8(A) and 240.24(A) limit the center of the grip of the operating handle, in its highest position, to 2.0 m (6 ft 7 in.) above the floor or working platform.

    Reference: NFPA 70, National Electrical Code, 2023, 404.8(A)

  9. What is the synchronous speed of a six-pole, 60-hertz induction motor?

    Answer: 1,200 rpm

    Synchronous speed = 120 × frequency ÷ number of poles = 120 × 60 ÷ 6 = 1,200 rpm. Four poles give 1,800 rpm, eight poles give 900 rpm and two poles give 3,600 rpm.

    Reference: NFPA 70, National Electrical Code, 2023, Motor speed formula (Ugly's, Chapter 1 formulas)

  10. Which statement describes a Class I, Division 1 location?

    Answer: Ignitible gas or vapor concentrations can exist in normal operation

    Section 500.5(B)(1) defines Class I, Division 1 as a location where ignitible concentrations of flammable gases, flammable liquid-produced vapors or combustible liquid-produced vapors can exist under normal operating conditions, frequent repair or leakage, or where faulty equipment could release them while causing electrical failure. Combustible dust is Class II and fibers are Class III.

    Reference: NFPA 70, National Electrical Code, 2023, 500.5(B)(1)

Sources

Questions last verified October 25, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.