New Jersey licensing exam

New Jersey Master Plumber Exam: Practice Test & Licensing Guide

The PSI trade exam for a New Jersey master plumber license: 100 questions on the 2021 National Standard Plumbing Code covering materials, traps, fixtures, water supply, drains and vents. Open book, 70% to pass.

Questions
100
Time limit
3.25 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Traps, Interceptors, and Backflow Prevention

What range of liquid seal depth must each fixture trap have under the 2021 NSPC?

Requirements at a glance

AgencyState Board of Examiners of Master Plumbers (Division of Consumer Affairs); exams by PSI
EligibilityAge 21 plus an approved apprenticeship and journeyman experience or an engineering degree route (see N.J.A.C. 13:32)
ExamsMaster Plumber and Master Plumber Practical (closed book), plus Business and Law
Fees$87 to PSI (Business and Law is $47), plus Board application and license fees

Candidates for a New Jersey master plumber license from the State Board of Examiners of Master Plumbers.

How to get licensed, step by step

  1. Apply to the board

    Get the Board's approval to test. It sends an Examination Eligibility Notice with instructions for paying and scheduling.

    New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)

  2. Schedule the master plumber exam and Business and Law with PSI

    Pay and schedule with PSI online or at (855) 340-3713. First-time candidates take all required exams on the same day. Fees are not refundable or transferable and are valid for one year.

    Schedule with PSI (NJ master plumbers) (opens in a new tab)

  3. Retake if needed

    Retake only the exams you failed, after the waiting period your board sets (6 months between attempts for most boards). Check your Eligibility Notice for the exact limits.

    Schedule with PSI (NJ master plumbers) (opens in a new tab)

  4. Get licensed

    PSI sends your results to the board. Contact the board for the license application, fees and insurance requirements.

    New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's outline, and check the bulletin again before test day. New Jersey adopted newer codes in August 2026, but the exam bulletins still name the 2023 NEC, the 2021 National Standard Plumbing Code and the 2021 IMC and IFGC.
  • First-time candidates take all required exams on the same day, so practice the trade exam and Business and Law together.
  • You can highlight, underline and index books you bring, but not write in them. The 2023 NEC is provided at the electrical and alarm test centers.
  • The National Standard Plumbing Code is numbered by chapter and section and is not the International Plumbing Code: tab the traps, drain, vent and water supply sections.
  • Materials (17), traps and backflow (15) and drains and waste (15) are almost half of the exam.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2021 NSPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • National Standard Plumbing Code (NSPC), 2021 Edition, Plumbing-Heating-Cooling Contractors Association (allowed in the exam room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Knowledge7
Materials, Uses, and Specifications17
Traps, Interceptors, and Backflow Prevention15
Plumbing Fixtures, Fixture Fittings, and Plumbing Appliances13
Water Supply Systems12
Drains and Waste (a. Indirect Waste, b. Roof Drain Piping)15
Specialty Plumbing4
Safety7
Vent Systems10

Exam day details

  • Administered by PSI Services for the New Jersey Division of Consumer Affairs boards.
  • Fee: $87 to PSI (the Master Plumber Practical is $106 separately). Board application and license fees are separate.
  • 100 questions in 195 minutes; 70 correct (70%) to pass.
  • Code questions follow the 2021 NSPC named in the bulletin. New Jersey adopted the 2024 NSPC in August 2026 with a grace period, but the PSI bulletin (3/9/2026) still lists 2021. Check the bulletin before test day.
  • Master plumber candidates take the Master Plumber, Master Plumber Practical (closed book) and Business and Law exams on the same day for the first attempt. If you fail, you can retest without a limit on attempts but must wait 6 months between attempts.
  • Your board (or committee) must approve your application first and sends an Examination Eligibility Notice. Then you pay and schedule with PSI by phone at (855) 340-3713 or online.
  • Exam fees are not refundable or transferable and are valid for one year from payment.
  • References may be highlighted, underlined and indexed before the exam but not written in; loose or attached papers are not allowed. A book PSI provides at the test center can't be marked.

Frequently asked questions

What's on the New Jersey master plumber exam?

100 questions: materials, uses and specifications 17, traps, interceptors and backflow prevention 15, drains and waste 15, plumbing fixtures 13, water supply systems 12, vent systems 10, general knowledge 7, safety 7 and specialty plumbing 4.

Which plumbing code does the exam use?

The 2021 National Standard Plumbing Code (PHCC), per the PSI bulletin. It is not the International Plumbing Code.

How often can I retake it?

As often as you need, but you must wait 6 months between attempts.

Free questions with answers

Show all 10 free questions and answers
  1. What range of liquid seal depth must each fixture trap have under the 2021 NSPC?

    Answer: 2 inches to 4 inches

    Section 5.3.2 requires a seal of not less than 2 inches and not more than 4 inches. Shallower seals are lost too easily to pressure swings; deeper seals tend to trap solids.

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 5.3.2

  2. A horizontal 8-inch building sewer will run 60 feet at the minimum slope allowed by the NSPC. What is the minimum total fall over the run?

    Answer: 3.75 inches

    Section 11.3.1.a.3 allows 1/16 inch per foot for 8-inch and larger pipe. 60 ft x 1/16 in/ft = 3.75 inches. Using 1/8 inch gives 7.5 inches and 1/4 inch gives 15 inches, which are the rates for smaller pipe.

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 11.3.1.a

  3. How far above the roof must a vent pipe terminate on an ordinary roof used only for weather protection?

    Answer: Not less than 6 inches

    Section 12.4.1 requires vents to terminate at least 6 inches above the roof, measured from the highest point where the vent intersects the roof. The 7-foot rule applies only to roofs used for other purposes.

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 12.4.1

  4. What minimum water pressure rating at 73 degrees F must water service piping have under the NSPC?

    Answer: 160 psi

    Section 3.4.2 requires water service piping to the building supply control valve to be pressure rated not less than 160 psi at 73 degrees F and to comply with NSF 61. The 200 psig rating applies only to combination domestic/fire services (3.4.2.1).

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 3.4.2

  5. What pressure rating at 73 degrees F is required for water service piping in a combination domestic and fire water service (no limited-area sprinkler exception)?

    Answer: 200 psig

    Section 3.4.2.1 requires combination domestic/fire water services to be rated at least 200 psig at 73 degrees F. The 160 psig value applies to ordinary services and to limited area sprinkler systems under the stated exception.

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 3.4.2.1

  6. A custom shower has six 2.5 gpm shower heads. Using Section 7.10.4, what minimum waste outlet pipe size is required (or multiple outlets as needed)?

    Answer: 3 inches

    Total flow is 6 x 2.5 gpm = 15 gpm. Section 7.10.4.c requires a 2-inch waste for up to 10 gpm and a 3-inch waste for up to 20 gpm, so 3 inches. A 2-inch outlet would handle only four heads.

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 7.10.4.c

  7. Where must hot water temperature be maintained by recirculation or heat tracing under Section 10.15.2?

    Answer: Where the developed length to an outlet exceeds 100 feet, to within 25 feet of that outlet

    Section 10.15.2.a requires temperature maintenance where the developed length of hot water piping to an outlet exceeds 100 feet from the source. The temperature must be maintained to within 25 feet of the outlet.

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 10.15.2.1.a

  8. A rough drain and vent system is tested with air. What test pressure and duration does the NSPC require?

    Answer: 5 psi held for at least 15 minutes

    Section 15.4.1.a.2 requires a uniform gauge pressure of 5 psi (or 10 inches of mercury) held without adding air for at least 15 minutes. Air testing is not permitted on plastic piping.

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 15.4.1.a.2

  9. Vacuum breakers for hose-type bedpan washers in a health care facility must be installed at what minimum height above the floor?

    Answer: 5 feet

    Section 14.7.b (also referenced by 14.8.1.c) requires vacuum breakers for hose-type bedpan washers to be not less than 5 feet above the floor.

    Reference: 2021 National Standard Plumbing Code, New Jersey Edition, Section 14.7.b

  10. A 6-foot-deep trench in Type C soil is excavated with sloped sides using the simplest allowable slope option, with no shield. What horizontal setback from the bottom edge to the top edge is needed on each side?

    Answer: 9 feet

    29 CFR 1926.652(b)(1)(i) allows sloping at no steeper than 1-1/2 horizontal to 1 vertical (34 degrees), and Appendix B sets the same 1-1/2:1 maximum for Type C soil. 6 ft deep x 1.5 = 9 feet of horizontal setback per side. A 1:1 slope (Type B) would give 6 feet, a 3/4:1 slope (Type A) 4-1/2 feet, and 12 feet would be a 2:1 slope.

    Reference: 29 CFR Part 1926 (OSHA Construction Standards), 29 CFR 1926.652(b)(1)(i); Subpart P Appendix B

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.