Requirements at a glance
| Exam | ICC B1: 60 questions, 2 hours, open book (IRC only), scaled score of 75 to pass |
|---|---|
| Code book | International Residential Code. Pick the exam edition your jurisdiction enforces (Utah: 2021) |
| Utah Limited Inspector | At least one current ICC certification (B1 is a common first) |
| Utah Combination Inspector | ICC Combination Inspector: B1, B2, E1, E2, P1, P2, M1 and M2 |
Building inspectors, plans examiners in training, and contractors moving into inspection. In Utah, a Limited Inspector license requires at least one current ICC certification such as B1, and a Combination Inspector license requires ICC Combination Inspector (B1, B2, E1, E2, P1, P2, M1 and M2).
Official links
How to get certified, step by step
Register with ICC
Create an account on ICC's site, choose B1 Residential Building Inspector and the IRC edition, then schedule a test center or online proctored exam.
Tab your IRC
Only the IRC is allowed. Tab chapters 3 (building planning), 4 (foundations), 5 (floors), 6 (walls), 7 (wall coverings), 8 (roof/ceiling) and 9 (roof coverings), plus the stair, guard and egress sections.
Pass the exam
60 questions in 2 hours: about 2 minutes each. Walls (27%), public safety (17%) and foundations (16%) are the biggest sections.
Apply for your Utah license
Utah has no separate state exam for inspectors: apply to DOPL with your ICC certificate.
DOPL: Limited Inspector license (opens in a new tab)DOPL: Combination Inspector license (opens in a new tab)
How to prepare
- Know the IRC tables you'll use constantly: footing sizes, fastening schedule (R602.3(1)), header spans, stair geometry, and egress window dimensions.
- Braced wall panels and wall bracing are dense. Spend extra time there.
- Practice speed. With only about 2 minutes per question, you need to know where things are without searching.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Residential Code (IRC), 2021 editionEssential
The only book allowed. Tab it by chapter and mark the tables you use most.
ICC store (opens in a new tab)Read free (opens in a new tab)
Official reference list (as published by the testing agency)
- International Residential Code (IRC), 2021 edition (the edition Utah enforces; ICC also offers other editions)
What's on the exam
Official content outline from International Code Council (ICC) (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Wall Construction and Coverings | 27 | |
| Public Safety and Special Construction | 17 | |
| Footings and Foundations | 16 | |
| Floor Construction | 14 | |
| Roof/Ceiling Construction | 14 | |
| Building Planning | 8 | |
| Code Administration | 4 |
The outline totals 100; the other items on the 60-question exam are unscored or unassigned.
Exam day details
- Administered by International Code Council (ICC).
- Fee: Set by ICC; see ICC's exam catalog for the current fee.
- Scope: one- and two-family dwellings, townhouses up to three stories, and accessory structures.
- Open book: only the IRC is allowed.
- Choose the exam edition that matches the code your jurisdiction enforces. Utah enforces the 2021 IRC.
- ICC reports a scaled score; 75 is passing.
- In Utah there's no separate state exam for building inspectors. DOPL issues the license based on your ICC certifications.
Frequently asked questions
How many questions are on the ICC B1 exam?
60 multiple-choice questions in 2 hours, open book with the International Residential Code. Wall construction (27%) and public safety (17%) are the largest sections.
Does B1 qualify for a Utah inspector license?
Utah's Limited Inspector license requires at least one current ICC certification. B1 is a common first one. The Combination Inspector license requires the full ICC Combination Inspector certification.
Which IRC edition should I study?
The one matching the exam edition you register for. Utah enforces the 2021 IRC, which is what our questions cover.
Free questions with answers
Show all 10 free questions and answers
A habitable bedroom measures 12 feet by 14 feet. It will rely on natural light, not the artificial-light exception. What is the minimum aggregate glazing area required?
Answer: 13.44 square feet
Section R303.1 requires habitable rooms to have glazing of at least 8 percent of the floor area. Floor area = 12 x 14 = 168 sq ft, and 168 x 0.08 = 13.44 sq ft. The 6.72 sq ft answer (168 x 0.04) is the minimum openable area for natural ventilation, not the glazing area. The 8.4 and 16.8 answers use 5 and 10 percent, which are not IRC figures.
Reference: 2021 International Residential Code, Section R303.1
A second-floor bedroom has a casement window with a net clear opening 20 inches wide by 41 inches high, and a sill 40 inches above the floor. Does it qualify as the emergency escape and rescue opening?
Answer: No, the net clear opening area is less than 5.7 square feet
Net clear area = 20 in x 41 in = 820 sq in, and 820 / 144 = 5.69 sq ft. That is below the 5.7 sq ft minimum in Section R310.2.1. The 5 sq ft reduction applies only to grade-floor openings, not to a second floor. Width (20 in) and height (41 in, at least 24 in) meet Section R310.2.2. The sill at 40 in is within the 44-inch maximum in Section R310.2.3, so 36 inches is the wrong limit.
Reference: 2021 International Residential Code, Section R310.2.1
A deck walking surface is 32 inches above grade at its outer edge. What is the minimum guard height along that open edge?
Answer: 36 inches
Section R312.1.1 requires guards on open-sided walking surfaces more than 30 inches above the floor or grade below, measured at any point within 36 inches horizontally of the edge. This deck at 32 inches needs a guard. Section R312.1.2 sets the minimum guard height at 36 inches above the walking surface. 34 inches applies only to guards on the open sides of stairs, measured from the line of the nosings, and 42 inches is the IBC commercial guard height.
Reference: 2021 International Residential Code, Section R312.1.2
Using Table R403.1(1), what is the minimum concrete footing size (width x thickness) for a two-story light-frame house with a basement, a 30 psf ground snow load, and soil with a 1,500 psf load-bearing value?
Answer: 19 x 6 inches
In Table R403.1(1), go to the 30 psf ground snow load block, find the row "2 story - plus basement" and read across to the 1,500 psf column: 19 x 6 inches. The 16 x 6 answer is the 1-story-plus-basement row, 14 x 6 is the same row at 2,000 psf soil, and 21 x 7 is the 50 psf snow block. Section R403.1.1 also sets an absolute minimum of 12 inches wide by 6 inches thick.
Reference: 2021 International Residential Code, Table R403.1(1)
In an area where the frost line is not the controlling depth, what is the minimum depth of exterior footings below the undisturbed ground surface?
Answer: 12 inches
Section R403.1.4 requires exterior footings to be at least 12 inches below the undisturbed ground surface. Where frost applies, Section R403.1.4.1 may require greater depth (below the frost line in Table R301.2) or another frost-protection method. Measure from undisturbed ground, not from fill or finished grade that has been raised.
Reference: 2021 International Residential Code, Section R403.1.4
A plumber notched the top edge of a sawn-lumber 2x10 floor joist (actual depth 9 1/4 inches) 2 inches deep, about 3 feet from the bearing on a 15-foot span. The notch is not in the middle third of the span and is not at the joist end. What is your finding?
Answer: Does not comply, because the notch exceeds one-sixth of the joist depth
Section R502.8.1 limits notches in sawn joists to one-sixth of the depth, a length of no more than one-third of the depth, and no location in the middle third of the span. One-sixth of 9.25 in = 1.54 in, and the 2-inch notch exceeds it. The one-fourth limit (9.25 / 4 = 2.31 in) applies only to notches at the ends of the member, and this notch is 3 feet in from the bearing. Being outside the middle third is necessary but not enough on its own.
Reference: 2021 International Residential Code, Section R502.8.1
An enclosed attic has 1,500 square feet of vented space. Neither condition of the Section R806.2 exception is met. What minimum net free ventilating area is required?
Answer: 10 square feet
Section R806.2 requires a minimum net free ventilating area of 1/150 of the vented space: 1,500 / 150 = 10 sq ft. The 5 sq ft answer (1,500 / 300) is allowed only under the exception: a Class I or II vapor retarder in Climate Zones 6 to 8, plus 40 to 50 percent of the venting high in the attic within 3 feet of the ridge. 15 sq ft assumes a 1/100 ratio, and 7.5 sq ft assumes 1/200.
Reference: 2021 International Residential Code, Section R806.2
What is the deepest notch allowed in a 2x6 stud (actual depth 5 1/2 inches) in an exterior wall?
Answer: 1 3/8 inches
Section R602.6 limits notches in studs in exterior walls or bearing partitions to 25 percent of the stud depth: 5.5 x 0.25 = 1.375 in = 1 3/8 inches. 2 3/16 in (40 percent) is the notch limit for nonbearing partitions, and 3 5/16 in (60 percent) is the maximum bored-hole size. Deeper notches need an approved stud shoe or other repair.
Reference: 2021 International Residential Code, Section R602.6
An exterior bearing wall supports only a roof and ceiling on a 24-foot-wide building with a 30 psf ground snow load. A window needs a header spanning 6 feet. Using Table R602.7(1), what is the smallest two-ply (2-2x) sawn-lumber header, and how many jack studs are required at each end?
Answer: 2-2x10 with 2 jack studs
In Table R602.7(1), "Roof and ceiling" block, 30 psf snow, 24-foot building width: 2-2x8 spans 5-9 (too short for 6-0), 2-2x10 spans 6-10 with NJ = 2, and 2-2x12 spans 8-1. The smallest two-ply header that reaches 6 feet is 2-2x10, and the NJ column requires 2 jack studs at each end. The 2-2x8 answer uses the 12-foot building width (7-7). Full-height (king) studs at each end are a separate requirement in Table R602.7.5.
Reference: 2021 International Residential Code, Table R602.7(1)
No. 15 asphalt felt is being installed as the water-resistive barrier on exterior walls. How must it be lapped?
Answer: Applied horizontally, upper layer over lower at least 2 inches, with at least 6-inch laps at end joints
Section R703.2 requires No. 15 felt and ASTM E2556 barriers to be applied horizontally, shingle-fashion, with the upper layer lapped over the lower layer at least 2 inches. Where joints occur, the lap must be at least 6 inches. Lapping the lower layer over the upper (reverse lap) directs water behind the barrier.
Reference: 2021 International Residential Code, Section R703.2
Sources
- ICC: B1 Residential Building Inspector exam content outline (PDF) (opens in a new tab)
- Utah DOPL: Building inspector licenses (opens in a new tab)
Questions last verified October 6, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.