Requirements at a glance
| Agency | Minnesota Department of Labor and Industry (DLI) |
|---|---|
| Experience | No experience requirement listed in the DLI exam guide; see DLI for the license rules (Minn. Stat. 326B.805) |
| Exam | 110 questions (about 60 scored on the roofing outline), 5.5 hours, 70% to pass |
| Books allowed | None of your own: DLI supplies the 2020 Minnesota Residential Code, statutes and rules and a calculator |
| Fees | $50 per personal-license exam (Minn. Stat. 326B.092), plus application and license fees |
Roofing contractors applying to DLI for a residential roofer license (Minn. Stat. 326B.805).
Official links
How to get licensed, step by step
Apply to DLI
Send DLI your residential roofer license and exam application. After you pass, you must also meet the bond and insurance requirements before DLI issues the license.
Minnesota Department of Labor and Industry (DLI) (opens in a new tab)DLI: residential building contractor, remodeler and roofer (opens in a new tab)
Schedule your exam
After DLI approves your application, you schedule the exam in DLI's iMS system. DLI gives exams at its St. Paul office (Tuesday to Thursday) and at outstate sites including Duluth, Mankato, Rochester and St. Cloud.
Take the exam
You have 5.5 hours and need 70%. The exam is open book with DLI-supplied references; no personal books, notes or electronic devices.
DLI: residential building contractor, remodeler and roofer (opens in a new tab)DLI Residential Examination Guide (PDF) (opens in a new tab)
Results and retakes
DLI mails results in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
How to prepare
- The residential exams are on the 2020 Minnesota Residential Code (Rules 1309, based on the 2018 IRC) and the 2020 Residential Energy Code, plus Minnesota statutes and rules. About 60 of the 110 questions are scored on the code content outline; the rest cover business, law and technical topics.
- DLI rates the Building Contractor exam hardest, then the Remodeler and Roofer exams. Know the Minnesota amendments, not just the model IRC.
- Every DLI exam is open book, but with DLI-supplied references only: a code book without tabs, the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, so practice finding answers fast rather than relying on tabs.
- DLI publishes no topic weights, so our topic split is an estimate. Several versions of each exam are in use, and some questions ask for more than one answer or the choice that does not apply.
- Know the roofer outline: bonding, roof pitch and layers of existing roofing, ice protection and underlayment laps, shingle application, flashing types and ventilation.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Minnesota Residential Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2020 Minnesota Residential Code (Minnesota Rules chapter 1309)Essential
DLI supplies it in the exam room. It is the 2018 International Residential Code with Minnesota amendments.
DLI Residential Building Contractor, Remodeler and Roofer Examination Guide (06/2020)
DLI's own content outline for the three residential exams, with sample questions and formulas.
Official reference list (as published by the testing agency)
- 2020 Minnesota Residential Code, Minnesota Rules chapter 1309 (the 2018 International Residential Code with Minnesota amendments), and the 2020 Minnesota Residential Energy Code
- Minnesota Rules chapters 1300, 1303, 1315, 1322, 1350 and 1360 and Minnesota Statutes 176, 181, 326B, 327A, 333 and 514 (in the DLI laws-and-rules booklet)
- DLI supplies the references and a desk calculator; you cannot bring your own.
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| General Roofing Principles and Estimating | 8 | |
| Roof Deck Requirements | 5 | |
| Underlayment | 6 | |
| Pitched Roofs | 12 | |
| Low-Sloped Roofs | 6 | |
| Roofing Fasteners | 6 | |
| Flashing | 8 | |
| Ventilation | 5 | |
| Reroofing | 4 |
Exam day details
- Administered by the Minnesota Department of Labor and Industry (DLI), which gives its own exams.
- Fee: $50 per personal-license exam (Minn. Stat. 326B.092). Application and license fees are separate.
- 110 questions in 5.5 hours; 70% to pass. About 60 of the 110 are scored on the code content outline; the rest cover business, law and technical topics DLI does not itemize. All questions are multiple choice with five options.
- DLI publishes the outline but no topic weights, so our topic split is an estimate of the 60 code-content questions. DLI rechecks scores within 5 percentage points of passing.
- The three residential exams are separate: the Remodeler exam uses the building contractor outline without its last two areas, and the Roofer exam has its own roofing outline. DLI rates the Building Contractor exam hardest.
- Open book with DLI-supplied references: you get the code book (without tabs), the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, notes or electronic devices.
- DLI gives the exam at its St. Paul office and outstate sites, scheduled after DLI approves your application. The time limit is 5.5 hours; the passing score is 70%.
- Results are mailed in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
- Some questions ask you to pick more than one answer (the question says how many) or the one choice that does not apply. Several versions of each exam are in use.
Note: DLI's residential guide (06/2020) prints the outline but no topic weights, so our topic split is an estimate. Our questions follow the 2020 Minnesota Residential Code (the 2018 IRC as amended by Rules 1309); the energy questions use Rules 1322, since we did not have the 2012 IECC text on file.
Frequently asked questions
What is on the Minnesota residential roofer exam?
General roofing principles and estimating, roof deck, underlayment (including ice protection), pitched roofs, low-sloped roofs, fasteners, flashing, ventilation and reroofing.
How many questions are on it?
110 in 5.5 hours; 70% to pass. About 60 are scored on the roofing outline.
Does the roofer exam include roofing math?
Yes. The outline lists basic roofing math, roof pitch and evaluating the number of layers on an existing roof.
Free questions with answers
Show all 10 free questions and answers
A roof has a pitch of 6:12. What does that ratio describe?
Answer: The roof rises 6 inches vertically for every 12 inches of horizontal run
Slope is written as units of vertical rise per 12 units of horizontal run. R905.2.2 uses this notation (for example 2:12 and 4:12) to set minimum slopes and underlayment methods. The other choices flip the ratio or measure along the rafter instead of horizontally.
Reference: 2018 International Residential Code, R905.2.2
Using the IRC's own percentage figures, an 8:12 roof is how many percent slope?
Answer: 67 percent
Slope percent is rise divided by run: 8 / 12 = 0.667, which R905.1.2 writes as 67-percent slope. A 4:12 roof is 33 percent and a 2:12 roof is 17 percent in the same chapter. Choosing 8 percent or 80 percent comes from reading the 8 as a percentage directly.
Reference: 2018 International Residential Code, R905.1.2
Wood structural panel roof sheathing may cantilever beyond a gable endwall by no more than what distance unless it is supported by gable overhang framing?
Answer: 9 inches
R803.2.3 limits unsupported panel sheathing to a 9-inch cantilever past the gable endwall. A wider overhang needs lookouts or gable overhang framing. Roofers see this when a new rake overhang is wider than the panels the framer left hanging.
Reference: 2018 International Residential Code, R803.2.3
Underlayment is being fastened with plastic cap nails where the table calls for cap nails. What does R905.1.1 require of the cap?
Answer: A nominal cap diameter of at least 1 inch
Cap nails or cap staples used for underlayment need a nominal cap diameter of not less than 1 inch. Metal caps are at least 32-gage, and plastic caps have a minimum edge thickness of 0.035 inch. Galvanizing alone does not satisfy the cap rule.
Reference: 2018 International Residential Code, R905.1.1, Table R905.1.1(3)
A shingle package must show compliance with ASTM D7158 and a classification from Table R905.2.4.1. For a site with an ultimate design wind speed of 168 mph, which D7158 class is acceptable?
Answer: Class H only
The table steps up with wind speed: D, G or H at 110 and 116 mph, G or H from 129 through 155 mph, and only H from 168 mph up. Class D shingles are tested for the lowest wind speeds only.
Reference: 2018 International Residential Code, Table R905.2.4.1
What minimum design slope does IRC R905.9.1 allow for a coal-tar built-up roof?
Answer: 1/8 unit vertical in 12 units horizontal
The code allows coal-tar built-up roofs a minimum design slope of 1/8:12 (1 percent). All other built-up roofs, modified bitumen and single-ply membranes need 1/4:12.
Reference: 2018 International Residential Code, R905.9.1
What is the minimum shank gage and head diameter for asphalt shingle roofing nails under IRC R905.2.5?
Answer: 12-gage shank with a 3/8-inch-diameter head
Asphalt shingle nails are galvanized steel, stainless steel, aluminum or copper roofing nails with a 12-gage (0.105 inch) shank and a head at least 3/8 inch in diameter, complying with ASTM F1667. Smaller shanks and heads pull through or loosen.
Reference: 2018 International Residential Code, R905.2.5
What is the minimum length of the roof portion of a kick-out flashing under Minnesota's amendment to IRC R903.2.1?
Answer: 2-1/2 inches
Minnesota requires a kick-out flashing to divert water away from where the eave of a sloped roof meets a vertical sidewall, and the kick-out on the roof must be at least 2-1/2 inches long. The base IRC only requires 'a flashing' there with no length.
Reference: Minnesota Rules, chapter 1309, Minn. R. 1309.0903 (amending IRC R903.2.1)
A Minnesota (Climate Zone 6) attic of 1,800 square feet has a Class I vapor retarder on the warm side of the ceiling, so the roofer uses the 1/300 exception in IRC R806.2. At minimum, how much net free area must the upper ventilators provide?
Answer: About 346 square inches, which is 40 percent of the total
1/300 x 1,800 = 6 sq ft = 864 sq in. The exception requires not less than 40 percent and not more than 50 percent of the area in upper ventilators within 3 feet of the ridge, so the minimum is 0.40 x 864 = 345.6 sq in (about 346), the maximum is 432, and the rest goes low in the bottom third. 691 is 40 percent of the 1/150 total.
Reference: 2018 International Residential Code, R806.2, Exception
Which existing roof covering prevents a roof recover under IRC R908.3.1.1?
Answer: Slate or clay tile
A recover is not permitted over slate, clay, cement or asbestos-cement tile, over a water-soaked or deteriorated roof, or over a roof with two or more coverings. A single layer of wood shingles can be recovered if R908.4 is satisfied.
Reference: 2018 International Residential Code, R908.3.1.1
Sources
- DLI Residential Building Contractor, Remodeler, Roofer Examination Guide (06/2020) (opens in a new tab)
- Minnesota DLI: residential building contractor, remodeler and roofer licenses (opens in a new tab)
- Minnesota DLI: license exam schedule (opens in a new tab)
Questions last verified November 9, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.