Requirements at a glance
| Agency | Your Kansas city or county licenses you; the International Code Council (ICC) gives the exam through Pearson VUE. There is no statewide license |
|---|---|
| Experience | Set by your city or county. Johnson County (license types A, B, C, DR) sets no years-of-experience rule: the company's qualifying individual shows a passing ICC exam or the required education and takes 8 hours of continuing education per license class each year, and the company carries general liability and workers' compensation insurance |
| Exam | KGP: 60 questions, 3 hours, 75% |
| Books allowed | 2018 International Building Code and 2018 International Plumbing Code |
| Fees | $115 per ICC exam (national T-series exams are $120), plus your city or county's certificate or license fees |
Roofing contractors and subcontractors applying for a Johnson County DR (roofing) license, or for a similar license from a Kansas city or county that accepts the ICC standard exam.
Official links
How to get licensed, step by step
Ask your city or county which exam it accepts
Kansas law lets each jurisdiction name the standard examinations it accepts as proof of competency. Confirm the exam and the experience rules before you pay.
Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)Kansas statute K.S.A. 12-1525 (standard examinations) (opens in a new tab)
Register for the roofing contractor/subcontractor exam (KGP) with ICC and Pearson VUE
Create an ICC account, pick the Kansas standard exam from the Exam Catalog and schedule a Pearson VUE appointment. If you fail, wait 10 days to retake.
Schedule with Pearson VUE (ICC exams) (opens in a new tab)ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)
Pass at 75% with your books
The exam is open book with four-option multiple choice and no penalty for guessing. Bring only the approved references.
ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)
Apply to your city or county
Send your passing score and proof of experience to the jurisdiction, with its fee. It issues the certificate or license and sets renewal rules.
Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)
How to prepare
- Study the edition the exam is built on: the 2017 NEC for electrical and the 2018 IPC, IMC and IFGC for plumbing and mechanical. Your city's adopted code can be newer.
- The exam is open book, but there is not time to look up every answer. Tab your books by chapter and table before exam day.
- The 2014 NEC / 2015 I-Code Kansas exams end December 1, 2026. If your jurisdiction wants a 2021-based exam, ask about the national ICC T-series instead.
- Types of roofing material and application (35%) and fasteners, flashings and drainage (28%) are most of the exam: tab IBC Chapter 15, especially Sections 1503, 1504 and 1507.
- Roof drains, gutters and scuppers use IBC 1502 and IPC Chapter 11; re-roofing (12%) is IBC Section 1511 in the 2018 edition.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 IBC and the 2018 IPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 International Building Code (IBC)Essential
Allowed in the exam room. The core of the building and roofing exams: permits, occupancy, egress, structural chapters and Chapter 15 roofing.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
2018 International Plumbing Code (IPC)Essential
Allowed in the exam room. Most of the plumbing exam: administration, fixtures, water, drainage and vents.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
Official reference list (as published by the testing agency)
- 2018 International Building Code (IBC) (allowed in the exam room)
- 2018 International Plumbing Code (IPC) (allowed in the exam room)
What's on the exam
Official content outline from International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Administration and General Requirements | 25 | |
| Types of Roofing Material and Application | 35 | |
| Fasteners, Flashings, Drainage and Scuppers | 28 | |
| Re-roofing | 12 |
The outline totals 100; the other items on the 60-question exam are unscored or unassigned.
Exam day details
- Administered by International Code Council (ICC), delivered by Pearson VUE, for Kansas cities and counties.
- Fee: $115 to ICC through Pearson VUE per exam. Your city or county's license fees are separate.
- 60 multiple-choice questions in 3 hours; 75% to pass.
- Open book: bring the approved references. Questions are four-option multiple choice with no penalty for guessing; 75% to pass.
- Kansas has no statewide electrician, plumber or mechanical license. ICC only tests; the city or county where you want to work sponsors you and issues the license.
- If you fail, wait 10 days to retake.
- The 2014 NEC / 2015 I-Code exams stop being offered December 1, 2026. These Kansas standard exams are based on the 2017 NEC and 2018 I-Codes; the national T-series exams cover the 2020 NEC and 2021 I-Codes.
Frequently asked questions
What's on the Kansas roofing contractor exam?
60 questions by weight: administration and general requirements 25%, types of roofing material and application 35%, fasteners, flashings and drainage 28% and re-roofing 12%.
Which code books does it use?
The 2018 International Building Code and the 2018 International Plumbing Code (the IPC covers roof drains, gutters and scuppers).
Which jurisdictions accept it?
Johnson County recognizes the KGP exam for its DR (roofing) license. Other cities and counties set their own rules, so confirm where you will work.
Free questions with answers
Show all 10 free questions and answers
A building has two existing layers of asphalt shingles in sound condition. The owner asks for a third layer of shingles to be installed over them. Under IBC 1511.3.1.1, this recover:
Answer: is not permitted, because the existing roof already has two or more applications of roof covering
Section 1511.3.1.1 prohibits a roof recover where the existing roof has two or more applications of any type of roof covering. Dryness, good attachment or manufacturer approval does not override that limit; the old layers must be removed.
Reference: 2018 International Building Code, Section 1511.3.1.1
A low-slope building with positive roof drainage is being re-roofed. An existing secondary (emergency overflow) drain system serves the roof. Under the exceptions in IBC 1511.1, which statement is correct?
Answer: New secondary drains are not required for the re-roof, but the existing secondary drains may not be removed unless replaced by compliant ones
Exception 2 to Section 1511.1 excuses a recover or replacement from the secondary drain or scupper requirement of 1502.2 where the roof has positive drainage. It adds that existing required secondary drains or scuppers cannot be removed unless they are replaced by ones designed and installed under 1502.2.
Reference: 2018 International Building Code, Section 1511.1, Exception 2
A roof is sloped 6:12 and will receive asphalt shingles. For design wind speed under 140 mph, what underlayment application does IBC Table 1507.1.1(2) call for?
Answer: One layer applied shingle fashion, parallel to and starting from the eave, lapped 2 inches, with 4-inch end laps offset 6 feet
Asphalt shingles on a slope of 4:12 or greater need one layer of underlayment applied shingle fashion from the eave and lapped 2 inches, with 4-inch end laps offset by 6 feet. The 4-inch laps everywhere apply at design wind speeds of 140 mph and higher.
Reference: 2018 International Building Code, Table 1507.1.1(2)
Wood shakes are being installed on a deck. Interlayment is required between courses. IBC 1507.9.5 says interlayment must comply with:
Answer: ASTM D226, Type I
Section 1507.9.5 and Table 1507.8 require shake interlayment complying with ASTM D226 Type I. Wood shingles have no interlayment requirement.
Reference: 2018 International Building Code, Section 1507.9.5
Metal flashing used at roof and wall intersections must be corrosion resistant and at least what thickness according to IBC 1503.2.1?
Answer: 0.019 inch (No. 26 galvanized sheet)
Section 1503.2.1 requires metal flashing to be corrosion resistant and not less than 0.019 inch (0.483 mm), which is No. 26 galvanized sheet.
Reference: 2018 International Building Code, Section 1503.2.1
Parapet walls must be coped with noncombustible, weatherproof materials. What is the minimum width of the coping under IBC 1503.3?
Answer: A width not less than the thickness of the parapet wall
Section 1503.3 says parapet walls shall be properly coped with noncombustible, weatherproof materials of a width not less than the thickness of the parapet wall.
Reference: 2018 International Building Code, Section 1503.3
A chimney on a pitched roof is 36 inches wide measured perpendicular to the slope. According to IBC 1503.5, what is required?
Answer: A cricket or saddle on the ridge side of the chimney
Section 1503.5 requires a cricket or saddle on the ridge side of any chimney or penetration wider than 30 inches measured perpendicular to the slope. Its covering must be sheet metal or the same material as the roof covering.
Reference: 2018 International Building Code, Section 1503.5
Under IBC 105.1, who must first apply to the building official and obtain a permit before reroofing or other regulated work begins?
Answer: Any owner or the owner's authorized agent who intends to construct, enlarge, alter, repair, move or demolish a building or structure
Section 105.1 says any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure must first apply to the building official and obtain the required permit.
Reference: 2018 International Building Code, Section 105.1
Which item is listed in IBC 105.2 as work that does not require a building permit?
Answer: A one-story detached accessory storage shed with a floor area of not more than 120 square feet
Section 105.2 exempts one-story detached accessory structures used as tool and storage sheds, playhouses and similar uses with a floor area of 120 square feet or less, fences not over 7 feet high and retaining walls not over 4 feet high (unless supporting a surcharge).
Reference: 2018 International Building Code, Section 105.2
A permit exemption listed in IBC 105.2 applies to a job. What does the code say about the work itself?
Answer: The exemption does not authorize any work to be done in violation of this code or other laws or ordinances
Section 105.2 states that exemptions from permit requirements shall not be deemed to grant authorization for work done in violation of the code or of other laws or ordinances of the jurisdiction.
Reference: 2018 International Building Code, Section 105.2
Sources
- ICC: State of Kansas Contractor/Trades Examination Information Bulletin (10/12/2026) (opens in a new tab)
- Pearson VUE: ICC exams (opens in a new tab)
- Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)
- Johnson County Contractor Licensing: exam information (opens in a new tab)
Questions last verified November 5, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.