Requirements at a glance
| Agency | California Contractors State License Board (CSLB); exams by PSI |
|---|---|
| Experience | 4 years of journey-level experience in the trade within the last 10 years |
| Exams | C-39 Roofing trade exam, plus the Law and Business exam |
| Format | Closed book, 4-choice, 3.5 hours per exam; question count and pass score not published |
| Study references | California Residential and Building Codes; NRCA Roofing Manual; Tile Roofing Industry Alliance manual; Cal/OSHA Title 8 |
| Fees | $450 application (one classification); $200 (sole owner) or $350 initial license fee after you pass; $25,000 contractor bond; fingerprints |
Qualifiers for a California C-39 Roofing contractor license. Taken together with the Law and Business exam.
Official links
How to get licensed, step by step
Pick your classification
Find the CSLB classification for your work. The qualifier named on the license needs 4 years of journey-level experience in it within the past 10 years.
Apply to CSLB
Submit the $450 application with your experience verification. CSLB reviews it and refers you to test.
California Contractors State License Board (CSLB) (opens in a new tab)CSLB: List of all fees (opens in a new tab)
Schedule Law and Business and the C-39 exam with PSI
Book both exams with PSI. Pass both within 18 months of acceptance; each exam sitting costs $51.43 paid to PSI. Passing results stay good for 5 years.
PSI: schedule your CSLB exam (877-392-6422) (opens in a new tab)
Bond, fees and fingerprints
After you pass, CSLB sends a Bond and Fee letter: file the $25,000 contractor bond, pay the initial license fee and complete fingerprints to receive your license.
How to prepare
- The CSLB exams are closed book and CSLB doesn't publish question counts or the passing score, so aim for steady scores well above 80% on our practice tests rather than a bare minimum.
- Use CSLB's free study guide for your classification: it lists the sections, approximate weights and the references the questions come from.
- Every license needs two exams (Law and Business plus the trade exam). Pass both within 18 months of CSLB accepting your application.
- Steep-slope roof projects are about 26% and low-slope about 17%: know underlayment, flashing, fastening and drainage details for each.
- Safety is about 22%: practice roof edge, fall protection and ladder rules from the Cal/OSHA roofing safety orders.
- Planning and estimating (about 22%) includes squares, waste and material takeoffs.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
CSLB examination study guide for your classificationEssential
Free from CSLB. Lists the sections, approximate weights and references for the exam.
2025 California Building, Electrical, Plumbing and Mechanical Codes
Not allowed in the exam room. CSLB's study guides cite the 2025 California codes (effective January 1, 2026).
Official reference list (as published by the testing agency)
- CSLB C-39 Roofing study guide (applies to exams on or after January 1, 2023)
- 2022 California Residential Code, Building Code and Energy Code as named in the guide
- Tile Roofing Industry Alliance manual; NRCA Roofing Manual
- Cal/OSHA Title 8 safety orders (roofing, sections 1724 and 1730)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Planning and Estimating | 22 | |
| Job Site Preparation for Roof Projects | 13 | |
| Low-Slope Roof Projects | 17 | |
| Steep-Slope Roof Projects | 26 | |
| Safety | 22 |
Exam day details
- Administered by PSI Services for the California Contractors State License Board (CSLB).
- Fee: $450 CSLB application fee (one classification), paid to CSLB. Separately, each exam sitting costs $51.43, paid directly to PSI (a retake costs it again, after a 21-day wait). Cancel or reschedule at least 2 days ahead to keep your fee. The $200 or $350 initial license fee and the $25,000 bond come after you pass.
- Closed book: no code books, notes or calculators from home. PSI provides a calculator, and every question has four choices with no penalty for guessing.
- You get 3.5 hours per exam and see your result on screen. A failing report breaks your performance down by section.
- Every license needs two exams: Law and Business plus the trade exam for the classification (C-61 has no trade exam). You must pass both within 18 months of CSLB accepting your application, and passing results stay good for 5 years.
- The qualifier needs 4 years of journey-level experience within the last 10 years. Each exam sitting costs $51.43 paid to PSI, and you must cancel or reschedule at least 2 days before the appointment to keep the fee.
- Work worth $500 or more (labor and materials) requires a California contractor license.
Note: CSLB does not publish the number of questions or the passing score for its exams. The 100-question practice length is ours, and the pass line shown in our practice tests is only a study target. Check CSLB's study guide and the PSI bulletin for current details.
Frequently asked questions
What's on the California C-39 exam?
CSLB lists approximate weights: steep-slope roof projects 26%, planning and estimating 22%, safety 22%, low-slope roof projects 17% and job site preparation for roof projects 13%.
Can I bring the NRCA manual to the exam?
No. The exam is closed book, so you need to know roofing materials, details and fall protection rules without looking them up.
How many questions are on the exam and what score do I need?
CSLB doesn't publish either number, so we don't state them. Each exam is closed book with 4-choice questions and 3.5 hours to finish. Your result appears on screen, and a failing report shows how you did by section.
Free questions with answers
Show all 10 free questions and answers
A flat rectangular roof measures 48 ft by 25 ft. How many roofing squares does it contain?
Answer: 12 squares
One roofing square covers 100 sq ft. Area = 48 x 25 = 1,200 sq ft; 1,200 / 100 = 12 squares. 120 comes from dividing by 10, 6 from dividing by 200, and 24 from dividing by 50.
Reference: General trade practice, Roofing square (100 sq ft)
Three-bundle architectural shingles are needed for a 16-square roof, with the waste already included in the square count. How many bundles are required?
Answer: 48 bundles
Shingles of this type are packaged at 3 bundles per square, so 16 squares x 3 = 48 bundles. 32 assumes 2 bundles per square, 64 assumes 4, and 53 adds a second 10% waste to bundles that already include it.
Reference: General trade practice, Bundles per square
A roof is built at 8:12. Over a horizontal run of 15 ft, how much does the roof rise?
Answer: 10 ft
An 8:12 pitch rises 8 in per 12 in of run. Rise = 15 x 8/12 = 10 ft. 22.5 ft inverts the ratio (15 x 12/8); 8 ft and 12 ft just repeat numbers from the pitch.
Reference: General trade practice, Roof pitch: rise per 12 in of run
Before a planned roof recover, you probe the deck and find the sheathing soft and water-soaked in several areas. Under the California Building Code, what applies?
Answer: A recover is not permitted; the covering must come off and the deck be repaired
CBC 1512.3 bars a recover where the existing roof or covering is water-soaked or has deteriorated so far that it is not an adequate base for more roofing. Extra felt, extra nails or patch metal do not make a wet, weak deck an adequate base, so tear off and correct the deck first.
Reference: 2025 California Building Code, 1512.3
Which of these is a protective coating type listed by the California Building Code for use over sprayed polyurethane foam roofing?
Answer: Silicone coating (ASTM D6694)
CBC Table 1507.13.3 lists acrylic (ASTM D6083), silicone (ASTM D6694) and moisture-cured polyurethane (ASTM D6947) coatings for SPF. The asphalt-based coatings appear in the general roof-coating table 1509.2, but not as SPF protective coatings.
Reference: 2025 California Building Code, Table 1507.13.3
Above-deck thermal insulation will be installed under a low-slope roof covering on a combustible deck. The California Building Code requires the insulation and covering, tested as an assembly, to pass which tests?
Answer: NFPA 276 or UL 1256
CBC 1508.1 permits above-deck thermal insulation when it is covered with an approved roof covering and the assembly passes NFPA 276 or UL 1256 (with exceptions for foam plastic, which follows Chapter 26, and for concrete or composite decks). ASTM E84, NFPA 285 and UL 790 test other things.
Reference: 2025 California Building Code, 1508.1
Asphalt shingles are to be installed on a 3:12 roof. How must the underlayment be applied under the California Building Code?
Answer: Double underlayment, as slopes from 2:12 up to 4:12 require
CBC 1507.2.2 requires double underlayment for asphalt shingles on slopes from 2:12 up to 4:12, applied per 1507.1.1: a half-width starter strip at the eaves, then full sheets lapped half a sheet plus 2 inches. A single layer is allowed only at 4:12 or steeper.
Reference: 2025 California Building Code, 1507.2.2 and 1507.1.1
Asphalt shingles go on a roof steeper than 4:12 in an area where the basic wind speed is below 140 mph, using a single layer of mechanically fastened felt underlayment. What lap and end-lap offset does the California Building Code specify?
Answer: Lap 2 inches shingle fashion; end laps 4 inches, offset 6 feet
For slopes of 4:12 or greater, CBC 1507.1.1 calls for one layer applied shingle fashion, parallel to and starting at the eaves, lapped 2 inches, with end laps of 4 inches offset by 6 feet. The other combinations transpose these numbers.
Reference: 2025 California Building Code, Table 1507.1.1(2)
Under Title 8 section 1670(a), personal fall arrest, restraint or positioning systems must be worn by employees exposed to a fall of more than what distance from the perimeter of a structure or an unprotected edge?
Answer: More than 7-1/2 feet
Section 1670(a) applies where work exposes employees to a fall in excess of 7-1/2 feet from the perimeter of a structure, unprotected sides and edges, leading edges or openings, and also to roofs steeper than 7:12 or other slopes steeper than 40 degrees that are not otherwise protected.
Reference: California Code of Regulations, Title 8, 1670(a)
An anchorage for a personal fall arrest system is not designed under the direction of a qualified person as part of a complete system with a safety factor of two. What must it support per employee attached?
Answer: 5,000 pounds
Section 1670(b)(10) requires fall-arrest anchorages to be independent of any anchorage supporting platforms and capable of supporting at least 5,000 pounds per employee attached, unless engineered as part of a complete system with a safety factor of at least two under a qualified person.
Reference: California Code of Regulations, Title 8, 1670(b)(10)
Sources
- CSLB: Examination study guides (content outlines) (opens in a new tab)
- CSLB: Examination FAQ (opens in a new tab)
- CSLB: List of all fees (opens in a new tab)
- CSLB: Get Licensed to Build (PDF) (opens in a new tab)
Questions last verified October 27, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.